155.2.4
DISPLAY-RCSU
The parameters of recorders can be displayed by means of the function DISPLAY-RCSU. Additionally the Source Group of each port is displayed.
There are several ways to request a display:
–
The recorders may be displayed by a range of pen numbers with PEN (lower) and PEN2 (upper) delimiting the range requested.
–
If neither PEN nor PEN2 are entered, all recorders on system are displayed.
–
If only PEN is entered, PEN2 will default to PEN, and only display the one port.
–
If only PEN2 is entered, PEN will default to the first port on the system. If PEN2 is less than PEN, all ports from PEN to PEN2 will be displayed.
–
If PEN is entered incorrectly, the incorrect parameter part (LTG, LTU, SLOT, CIRC) will be replaced with the appropriate minimum value for that part.
–
If PEN2 is entered incorrectly, the incorrect parameter part (LTG, LTU, SLOT, CIRC) will be replaced with the appropriate maximum value for that part.
–
Configured recorders may also be displayed by their application type (RECAPL). For RECAPL=HMUSIC it is possible to specify music-on-hold numbers and/or to ask for a list of station numbers that have a reference (introduced through AMO SBCSU) for the music-on-hold recorders being displayed (REFRN=YES).
–
Unoccupied ports suitable for recorders may also be displayed (TYPE=CFIG). This is useful when determining all available ports that support recorder devices in preparation for ADDing a recorder. Since any recorder application may be created at an appropriate port, the parameter RECAPL will be ignored if input with TYPE=CFIG.
–
Recorders may be displayed by their activation status: activated (A) or deactivated (D). If a recorder is deactivated conditional or immediate by AMO, blocked by dependability due to a fault, blocked remotely or blocked by a hierarchical block, then the status ACT is displayed as ’B’ for blocked and the recorder will be displayed for TYPE=D. If the recorder is deactivated long term, then the status ACT is displayed as ’N’ and the recorder will be displayed for TYPE=D. If the recorder is not blocked or deactivated, then the status ACT is displayed as ’Y’ even if the board is not present or is not the correct type and the recorder will be displayed for TYPE=A.
To determine the status of the recorder, use AMO SDSU
(DIS-SDSU:,,PEN,PER3,<LTG>,<LTU>,<SLOT>,<CIRC>;).
Examples
Display all recorders for announcements
DISP-RCSU:RECAPL=ACDR;
Display all recorders for music
DISP-RCSU:RECAPL=ACDMUS;
Display all recorders for music-on-hold
DISP-RCSU:RECAPL=HMUSIC;
Display all available ports for recorders
DISP-RCSU:TYPE=CFIG;
Display all recorders deactivated
DISP-RCSU:TYPE=D;
All recorders
DISP-RCSU;
One specific pen
DISP-RCSU:1-1-49-1;
Recorders within a certain range
DISP-RCSU:1-1-49-0,1-2-67-3;
Procedure Overview
Command Code
Parameter
DISPLAY-RCSU
[PEN=<GG-UU-BBB-SS>],[PEN2=<GG-UU-BB-SS>]
,[TYPE=<param>]
|,[RECAPL=ACDR];
|,[RECAPL=ACDMUS];
|,[RECAPL=HMUSIC],[HMUSIC=<number>],[REFRN=<param>];
Examples:
1.
Display a specific recorder at 1-2-37-0.
Input:
DISP-RCSU:PEN=1-2-37-0;
Output:
-----------+--------------+--------------+--------------+--------------+
PEN | 01-02-037-00 | 00-00-000-00 | 00-00-000-00 | 00-00-000-00 |
-----------| | | | |
SRCGRP: | 1 | | | |
-----------+--------------+--------------+--------------+--------------+
ACT | Y | | | |
OPMODE | CONTINUOUS | | | |
OPTYPE | RANDOM | | | |
COFIDX | 3 | | | |
CIRCIDX | 5 | | | |
CLASSMRK | G711 | | | |
| | | | |
| | | | |
| | | | |
RECAPL | ACDMUS | | | |
RECNUM | | | | |
MUSNUM | 1 | | | |
HMUSIC | | | | |
LENGTH | | | | |
-----------+--------------+--------------+--------------+--------------+
2.
Display a range of recorders from 1-2-37-0 to 1-2-37-3.
Input:
DISP-RCSU:PEN=1-2-37-0,PEN2=1-2-37-3;
Output:
PEN | 01-02-037-00 | 01-02-037-01 | 01-02-037-02 | 01-02-037-03 |
-----------| | | | |
SRCGRP: | 1 | 1 | 1 | 1 |
-----------+--------------+--------------+--------------+--------------+
ACT | Y | B | N | Y |
OPMODE | CONTINUOUS | DEMAND | CONTINUOUS | CONTINUOUS |
OPTYPE | RANDOM | FIXED | RANDOM | RANDOM |
COFIDX | 3 | 2 | | |
CCTIDX | 5 | 2 | | |
CLASSMRK | G711 | G711 | G711 | G711 |
| | | | |
| | | | |
| | | | |
RECAPL | ACDMUS | ACDR | ACDR | ACDMUS |
RECNUM | | 1 | 2 | |
MUSNUM | 1 | | | 2 |
HMUSIC | | | | |
LENGTH | | 14 | 3 | |
-----------+--------------+--------------+--------------+--------------+
3.
Display all recorders configured for ACD recorded announcements.
Input:
DISP-RCSU:RECAPL=ACDR;
Output:
PEN | 01-03-049-01 | 01-02-037-01 | 01-02-037-02 | 01-03-067-01 |
-----------| | | | |
SRCGRP: | 1 | 1 | 1 | 1 |
-----------+--------------+--------------+--------------+--------------+
ACT | Y | B | N | Y |
OPMODE | CONTINUOUS | DEMAND | CONTINUOUS | DEMAND |
OPTYPE | RANDOM | FIXED | RANDOM | FIXED |
COFIDX | 1 | 2 | | |
CCTIDX | 1 | 2 | | |
CLASSMRK | G711 | G711 | G711 | G711 |
| | | | |
| | | | |
| | | | |
RECAPL | ACDR | ACDR | ACDR | ACDR |
RECNUM | 3 | 1 | 2 | 4 |
MUSNUM | | | | |
HMUSIC | | | | |
LENGTH | 5 | 14 | 3 | 25 |
-----------+--------------+--------------+--------------+--------------+