155.3
Parameter Description
ACT
Recorder activation required
Type of Input
:
Single value, optional
Possible Values
:
Y(YES)
do activate the recorder
N(NO)
do not activate the recorder
Default Value
:
Y
CCTIDX
index into timer block table for SLMA/SLMA2/SLMAR circuit (applies to SLMA Q2141-X, Q2157-X, SLMA2 Q2146-X and to SLMAR Q2480-X only; see AMO PTIME, TYPE=SLMA1 for the times to be set)
Type of Input
:
Single value, optional
Possible Values
:
numeric, 0-16
Default Value
:
16 (null value)
CLASSMRK
DNIL classmarks (for feature IPDA)
Type of Input
:
4 single values, concatenated with ’&’, optional
(ADD / CHANGE)
VAD
voice activity detection
EC
echo cancellation
G711
no voice compression, according to G.711
G729
voice compression (mandatory) according to G.729A
G729OPT
voice compression (optional) according to G.729A
INIT
initialisation of classmarks to default
NONE
deactivation of all classmarks
Default Value
G711
COFIDX
index of cofi data file to be loaded
Type of Input
:
Single value, optional
Possible Values
:
0 = Data block for Germany
1 = Data block for Austria
2 = Data block for Australia
3 = Data block for Spain and Belgium
(L > 2x250 Ohm)
4 = Data block for Spain and Belgium
(L <= 2x250 Ohm)
The default value to be assigned for Spain and Belgium is 4.
5 to 7
reserved for future use
Default Value
:
0
HMUSIC
Number of music-on-hold recording
Type of Input
:
Single value, optional
Possible Values
:
numeric, 1-150
Default Value
:
lowest available number
LENGTH
Length of recorded announcement in seconds
Type of Input
:
Single value, optional
Possible Values
:
numeric, 1-90
1 - 16
for ACDR, RANDOM
1 - 14, 15 - 90 in increments of 5
for ACDR, FIXED START
Default Value
:
3 seconds
for ACDR, RANDOM
none
for ACDR, FIXED START
MUSNUM
Number of music recording
Type of Input
:
Single value, optional
Possible Values
:
numeric, 1-32
Default Value
:
lowest available number
NO
Number of recorders to be created
Type of Input
:
Single value, optional
Possible Values
:
numeric, 1-30
Default Value
:
1
When the parameter NO is entered, the parameter PEN, which
describers the starting port, can also be entered.
OPMODE
Operation mode for recorders
Type of Input
:
single value, mandatory (ADD)
single value, optional (CHANGE)
Possible Values
:
DEMAND
Announcement on demand
CONT
Announcement is played continuously
Default Value
:
none
Note:
DEMAND is only allowed with OPTYPE FIXED.
CONT is only allowed with OPTYPE RANDOM.
OPTYPE
Operation type for recorder
Type of Input
:
single value, mandatory (ADD)
single value, optional (CHANGE)
Possible Values
:
RANDOM
Random start
FIXED
Fixed start
Default Value
:
none
PEN
Port Equipment Number (LTG-LTU-SLOZ-CCT)
Type of Input
:
4 single values, concatenated with -, mandatory
(CHANGE / DELETE)
4 single values, concatenated with -, optional
(ADD / DISPLAY / REGENERATE)
Possible Values
:
numeric, 0-145
in the form of g-uu-sss-ccc
g
= LTG number 1 (no other values)
uu
= LTU number
1-15 in Host System
17-99 in Access Points
16 not defined
sss
= SLOT 1- 121
ccc
= Circuit 0 - 254
Default Value
:
For ADD command only: the AMO searches the system for an
available port matching the rest of the parameters.
For DISPLAY and REGEN: first pen of system
A suitable module must be configured to the slot addressed by PEN (AMO BCSU).
The possible LTU and Slot values for PEN depend on the systems architecture and can be found in the BCSU AMO description.
The possible Line values depend on the module type and its functionality.
They can be listed using DISP-BCSU: TYPE=PEN [,LTG=, LTU=, SLOT=, CCT=]; which will also output the actual PEN status (e.g. NOT CONNECTED).
PEN2
Port Equipment Number upper limit
Type of Input
:
4 single values, concatenated with -, optional
the form of gg-uu-sss-cc
Possible values
:
For description - see PEN
Default value
:
PEN value if PEN entered, else end of system
RECAPL
Application of the selected recorder
Type of Input
:
single value, mandatory (ADD)
single value, optional (CHANGE / DISPLAY / REGENERATE)
Possible values
:
ACDR
ACD announcement recorder
ACDMUS
ACD music recorder
HMUSIC
music-on-hold recorder
Default Value
:
none
RECNUM
Number of recorded announcement
Type of Input
:
single value, optional
Possible Values
:
numeric, 1-206
Default Value
:
lowest available number
REFRN
Listing of stations referencing music-on-hold recorders required
Type of Input
:
Single value, optional
Possible Values
:
Y(YES)
do list station numbers
N(NO)
do not list station numbers
Default Value
:
Y
SRCGRP
Source group index
Type of input
1 to 2 single values, concatenated with "&"
optional
Possible Values
1 - 255
TYPE
Type of output
Type of Input
:
Single value, optional
Possible Values
:
A
Activated ports, in service
D
Deactivated ports, not in service
CFIG
unoccupied ports suitable for
recorder ConFIGuration
Default Value
:
A and D
Activate and deactivated
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.