181.3
Parameter Description
ALARMNO
Alarm number of logical device class (Alarm must have been assigned with AMO-VADSU, ANTYPE=PERS (for 520-583) or ANTYPE=DIR (for 8 -519) before)
*** only relevant for HTBMNGR, HTBPHONE ***
Type of Input
:
Single value, optional
Possible values
:
0 (no alarm assigned)
8 - 583
Default value
:
0
COS1
COS2
Class of service1
Class of service 2
Type of input
:
single value, mandatory (ADD)
single value, optional (CHANGE)
Possible Values
:
1 - 1000
COSX
class of service switchover group
*** only relevant ifor HTBMNGR, HTBPHONE, HTBEXT, HTBLINE, TCLOG, TCEXT ***
Type of input
:
single value, optional
Possible Values
:
0-15
Default Value
:
0
DEV
Devicetype
Type of input
:
single value, mandatory
Possible Values
:
HTBMNGR, HTBPHONE, HTBEXT, HTBLINE, DTE, TCLOG, TCEXT
see parameter DVCFIG.
DIGNODIS
Digite with no display
*** only relevant ifor HTBMNGR, HTBPHONE ***
Type of input
:
single value, optional
Possible Values
:
YES, Y, NO, N
Default Value
:
NO
DPLN
Feature access group, dial plan group
Type of input
:
single value, optional
Possible Values
:
0 - 15
Default Value
:
0
DSSTNA
Direct station select tone A
(see AMO ZAND, CP=CMALTONE and AMO DTIM1, parameter VCHATONE, VCHAPAU)
*** only relevant ifor HTBMNGR, HTBPHONE, HTBLINE, TCLOG ***
Type of input
:
single value, optional
Possible Values
:
YES, Y, NO, N
Default Value
:
NO
DSSTNB
Direct station select tone B
(see AMO ZAND, CP=CMALTONE and AMO DTIM1, parameter VCHATONE, VCHAPAU)
*** only relevant ifor HTBMNGR, HTBPHONE, HTBLINE, TCLOG ***
Type of input
:
single value, optional
Possible Values
:
YES, Y, NO, N
Default Value
:
YES
DVCFIG
Device configuration
Type of input
:
single value, concatendated single value (max.2) mandatory
Possible Values
:
DTE
Subscriber with Data Terminal Equipment (only in combination with
HTBMNGR, HTBPHONE, HTBEXT)
HTBLINE
Hicom Trading Board Line
HTBMNGR
Hicom Trading Board Manager
HTBPHONE
Hicom Trading Board Phone
HTBEXT
Hicom Trading Board Extension Line
TCLOG
Logical Telecommuting Subscriber
TCEXT
Telecommuting Extension Line
HMUSIC
Number of muic on hold recording (AMO-RCSU)
*** only relevant for TCLOG ***
Type of input
single value, optional
Possible Values
0 - 150
Default Value
0
INS
Station(s) in service?
Type of input
:
single value, optional
Possible Values
:
YES
= The station terminals will be released for call
processing
NO
= The station terminals are not put into service (data
pre-assigned)
Default Value
:
YES
ITR
Internal traffic restriction group / closed user group
Type of input
:
single value, optional
Possible Values
:
0 - 15
Default Value
:
0
LCOSD1
LCOSD2
LCR-class of service 1 (data - see AMO-COSSU, TYPE=LCOSD)
LCR-class of service 2 (data - see AMO-COSSU, TYPE=LCOSD)
*** only relevant ifor OPT = HTB ***
Type of input
:
single value, mandatory
Possible Values
:
1 - 1000
LCOSV1
LCOSV2
LCR-class of service 1 (voice - see AMO-COSSU, TYPE=LCOSV)
LCR-class of service 2 (voice - see AMO-COSSU, TYPE=LCOSV)
Type of input
:
single value, mandatory
Possible Values
:
1 - 1000
NEWNO
New station number (STNO) to be assigned.
Input type
:
Single value, optional
Possible values
:
The station number must exist in the dial plan (AMO WABE). Only 1 single
value between 0 and 999999999999 is permissible).
Note
:
If the STNO to be changed has been declared as a a single value, then NEWNO changes the old station number to the new one.
If a range has been entered for the parameter STNO, the NEWNO value is used as the first station number in the new range. If there are gaps in the STNO range (stations not created), these gaps are included in the new range.
OFFTYPE
Type of deactivation order
controls both station locking and circuit data loading
*** In action CHANGE only relevant in connection with parameters ASYNCT and PSTNO ***
Type of input
:
single value, optional
Possible Values
:
NL
no lock, no downloading of circuit data
DC
deactivate with camp-on (soft lock)
DI
deactivate immediatelly (hard lock)
Default Value
:
DC
Note
:
After CHANGE command is executed, the station is switched back to the
original dependability state (different to AMO DSSU handling).
OPT
Option (branch parameter)
Type of input
:
single value, mandatory
Possible Values
:
HTB
=
Hicom Trading Board
TC
=
Telecommuting
OPTIDX
Index into option table (AMO-ZAND) for functional device
*** only relevant for HTBEXT, TCEXT, DTE ***
Type of input
:
single value, optional
Possible Values
:
1-10
Default Value
:
10
for all protocols
PEN
Port equipment number of a station (LTG-LTU-SLOT-CCT)
Type of Input
:
Single value, optional
Possible values
:
g-uu-sss-ccc
g
= LTG Number: 1 (no other value)
uu
= LTU Number:
–
1 - 15 in HHS (Host Shelf)
–
16 not defined
–
17 - 99 in AP (Access Point Shelf)
sss
= Slot Number: 1 - 121
ccc
= Circuit Number: 0 - 254
Default Value
:
First suitable PEN for a station creation
A suitable module must be configured for the slot addressed by PEN (AMO BCSU)
The possible LTU and Slot values for PEN depend on the systems architecture
and can be found in the BCSU AMO description.
The possible Circuit values depend on the module type and its functionality.
They can be listed using DISP-BCSU: TYPE=PEN [,LTG= , LTU= , SLOT= , CCT= ] ;
which will also output the actual PEN status (e.g. NOT CONNECTED).
PROT
Protocol variant for functional device
*** only relevant ifor HTBEXT, TCEXT, DTE ***
Type of input
:
single value, optional
Possible Values
:
SBDSS1
= Protocol DSS1
SBEDSR1
= EURO-ISDN-Protocol EDSS1 RESERVE 1
SBEDSR2
= EURO-ISDN-Protocol EDSS1 RESERVE 2
SBEDSR3
= EURO-ISDN-Protocol EDSS1 RESERVE 3
SBEDSR4
= EURO-ISDN-Protocol EDSS1 RESERVE 4
Default Value
:
SBDSS1
PSTNO
Partner station number
*** only relevant ifor HTBMNGR ***
Type of input
:
single value, optional
mandatory
ADD
optional
CHANGE
Possible Values
:
max. 22 digit number 0-9,*,#,A-D
The partner station number must point in digit analysis to a subscriber in another node.
RCBKB
Reject call back on busy
*** only relevant ifor OPT = HTB and DVCFIG = TCLOG ***
Type of input
:
single value, optional
Possible Values
:
YES, Y, NO, N
Default Value
:
NO
RCBKNA
Reject call back on no answer
*** only relevant ifor OPT = HTB and DVCFIG = TCLOG ***
Type of input
:
single value, optional
Possible Values
:
YES, Y, NO, N
Default Value
:
NO
REP
Number of add-on devices (e.g. repetory dialler)
*** only relevant ifor HTBLINE ***
Type of input
:
single value, optional
Possible Values
:
0-4
Default Value
:
0
SPDI
Station with speed calling individual
*** only relevant ifor OPT = HTB ***
Type of input
:
single value, optional
Possible values
:
0, 10, 20, 30 (0 means ‘No individual speed dialing’)
Default value
:
0 (‘No individual speed dialing’)
SPDC1
Central speed calling list 1
*** only relevant ifor OPT = HTB and DVCFIG = TCLOG ***
Type of input
:
single value, optional
Possible values
:
0 - 15 for ADD command
0 - 16 for CHANGE command (16 means ‘No central speed dialing list 1‘)
Default value
:
No central speed dialing list 1
SPDC2
Central speed calling list 2
*** only relevant ifor OPT = HTB and DVCFIG = TCLOG ***
Type of input
:
single value, optional
Possible values
:
0 - 15 for ADD command
0 - 16 for CHANGE command (16 means ‘No central speed dialing list 2‘)
Default value
:
No central speed dialing list 2
SSTNO
Secret station number
*** only relevant ifor OPT = HTB ***
Type of input
:
single value, optional
Possible Values
:
YES
= The user’s station number does not appear on the
called party’s display (internal and external)
NO
= The user’s station number does appear on the
called party’s display (internal and external)
ONLYEXT
= The user’s station number does not appear on
the external station’s display. Instead, a
replacement number (configured by AMO
KNMAT) is displayed
ONLYEX0
= Neither the user’s station number nor a
replacement calling number is displayed at the
external station’s display.
Default Value
:
NO
STD
Number of key layout/map standard
*** only relevant ifor HTBMNGR, HTBPHONE, HTBLINE, TCLOG ***
Type of input
:
single value, optional
Possible Values
:
0-127
Default Value
:
0
STNO
Station number
Type of input
:
single value, mandatory (ADD HTBMNGR)
single value, chained single values, range, mandatory (ADD other devices , CHANGE, DELETE)
single value, chained single values, range, optional
(DISPLAY, REGENERATE)
Possible Values
:
0 - 999999999999
The station number must be present in the dialing plan.
When entering ranges, please ensure that the second number is always the higher one and that both numbers have the same length.
A maximum of 600 station numbers may be included in a range
TRACE
Malicious call trace allowed
*** only relevant for OPT = HTB ***
Type of input
:
single value, optional
Possible Values
:
YES, Y, NO, N
Permitted allocations of device constellation to the modules on which a subscriber has been added (see table).
Table 11
Allocation of device constellation to the modules
OPT
Device constellation
Module
FCT-ID
HTB
HTBMNGR&DTE, HTBPHONE&DTE, HTBEXT, HTBEXT&DTE, HTBLINE
SLMY
1
TC
TCLOG, TCEXT
WAML2
2
TYPE
Desired station configuration options
Type of input
:
single value, optional
Possible Values
:
TERMDATA
Display all terminal data for terminals assigned with SSCSU
TRACE
Display all terminal data for terminals assigned with SSCSU and TYPE=TRACE
DEV
Output all stations which include a specific device type in the station configuration (specified with parameter DEV)