207.5.7
REGENERATE-VADSU
Regenerating the validation data of central, peripheral, logical or all alarms.
Any exisiting personal or directional alarms are completely regenerated by the ADD command.
All other alarms (always existing) are regenerated by means of CHANGE commands. Only those alarms are regenerated whose validation data (THRESHD1, THRESHD2, TIME1, TIME2, TIME, PRIO, HWCONT) deviates from the basic initialization data, i.e. those which have been changed using the AMO VADSU. In the same way, only the validation values which deviate from the initialization data will be regenerated.
The validation table with the basic initialization values, which is stored on the hard disk, serves as a reference.
The assignments of the personal and directional alarm numbers are regenerated using the AMOs SBCSU, SCSU, TACSU, TDCSU and TSCSU.
Procedure Overview
Command Code
Parameter
REGENERATE-VADSU
[ALARMGR=CENTRAL],[ALARMNO=<number>];
|[ALARMGR=PERIPHER],[ALARMNO=<number>];
|[ALARMGR=LOGICAL],[ALARMNO=<number>];
Example
Regenerate central alarm 1.
Input:
REG-VADSU:CENTRAL,1;
Output:
CHANGE-VADSU:MMA,CENTRAL,1,,3,300,300,,,;