10.2.7.5. Output of Statistical Information on the Signaling Connection Previous topic Parent topic Child topic Next topic

If monitoring is active for the message runtime or the message throughput, the system only signals the results of measurements if limits are breached.
It is therefore very difficult to say if the limits configured were set too low or even much too high.
For this reason, the cyclical output of measurement data can be set at the operating terminal.
You can set whether or not measurement data should be output cyclically for every access point.
Data is only output, however, if
  • monitoring is active for the message runtime or the message throughput
  • output is generally enabled with the AMO-DIAGS (CC/HSR option S00)
The measurement data are output with the message F8289
IMPORTANT:
The cyclical query and output of measurement data generates a high load in the system. There is also a danger that important error messages will be overlooked in the surge of measurement data. As a result, the output of measurement data may only be selectively used for a limited number of access points simultaneously. The output release should only be used for a manageable period of time.
For further information (e.g. on generation) please refer to Gateways HG 3500 and HG 3575 > Section 11.11, “TYPE SIGQOS - Quality Monitoring for the Signaling Connection over IP”.