Collapse AllExpand All

2.14.12. Resetting the Parameters to Default Values Previous topic Parent topic Child topic Next topic

If the parameters of one or all branches of the STMI2/4/STMIX/STMIY data are to be reset to default values, e.g. after being changed temporarily for diagnostic work, this can be performed in the INITCGW branch. The example sets all DMCDATA parameters to their default values.
assistant-2.gif
Initialization and reloading (where required) can only be performed in expert mode.
Expert Mode > OpenScape 4000 > Expert Access > Open ...<IP> using AMO (see AMO command)
comwin-2.gif
CHANGE-CGWB:MTYP=INITCGW,LTU=5,EBT=91,TYP=DMCDATA;
The changes under TYPE ASC, DSP, MGNTDATA, SIPTRERH, WBMDATA, DLSDATA (DLSACPAS) and JB become effective immediately without interrupting operation.
Changes under TYPE DMCDATA, GKDATA, GLOBIF, GWDATA, GWSECTOR, H235DATA, SIPTRSSA and DLSDATA (DLSIPADR & DLSPORT) become effective after the HG 3500 has been restarted with RESTART-BSSU:ADDRTYPE=PEN,LTU=5,SLOT=91.
IMPORTANT:
Existing links are disconnected.