21.8.7. Desk Phones CP Configuration Previous topic Parent topic Child topic Next topic

A CP100/ CP110/ CP200/ CP210/ CP400/ CP410/ CP600/ CP700/CP700X/ CP710 HFA terminal will be configured as described in Chapter 8, “HFA (IP) Terminal at STMI”.
Key assignment
A standard key layout is predefined in AMO TAPRO in each case for CP100/CP110/ CP200/ CP210/ CP400/ CP410/ CP600/ CP700/CP710 HFA.
CP410 standard key layout should be used for OpenScape Desk Phone CP410 or CP710 with KM410 (Key module with 16 free programmable function keys) connected.
CP700 standard key layout should be used for OpenScape Desk Phone CP410 or CP710 with KM710 (Key module with 12 free programmable function keys) connected.
Desk Phone CP
Key layout (STD in AMO TAPRO)
OpenScape Desk Phone CP100
112
OpenScape Desk Phone CP200
109
OpenScape Desk Phone CP400
110
OpenScape Desk Phone CP600
111
OpenScape Desk Phone CP700/CP710/CP410 (with KM710)
113
OpenScape Desk Phone CP110 114
OpenScape Desk Phone CP410/CP710 (with KM410) 115
Sample standard key layouts for CP100 variant:
<DISPLAY-TAPRO:TYPE=STD,STD=112;
DISPLAY-TAPRO:TYPE=STD,STD=112;
H500:  AMO TAPRO STARTED
+-----+---------+--------------------------------------------------------------+
| STD | DIGTYP  | "SERVICE INFORMATION"          KEY LAYOUT                    |
+-----+---------+--------------------------------------------------------------+
| 112 | CP100   |  "DESKPHONE CP100                                   "        |
|     |         |   1 SPKR-FIX  2 FIX       3 MUTE-FIX  4 FIX       5 FIX      |
|     |         |   6 FIX       7 CH-FIX    8 MB-FIX    9 VACANT   10 VACANT   |
|     |         |  11 VACANT                                                   |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA1  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA2  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA3  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA4  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
+-----+---------+--------------------------------------------------------------+
AMO-TAPRO-111       PROGRAMMABLE KEY DEFINITION FOR DIGITAL TERMINALS           
DISPLAY COMPLETED;
      
Sample standard key layouts for CP200 variant:
 <DIS-TAPRO:STD,109;
DIS-TAPRO:STD,109;
H500:  AMO TAPRO STARTED
+-----+---------+--------------------------------------------------------------+
| STD | DIGTYP  | "SERVICE INFORMATION"          KEY LAYOUT                    |
+-----+---------+--------------------------------------------------------------+
| 109 | CP200   |  "DESKPHONE CP200                                   "        |
|     |         |   1 SPKR-FIX  2 HS-FIX    3 MUTE-FIX  4 TRNS-FIX  5 HOLD-FIX |
|     |         |   6 CONF-FIX  7 CH-FIX    8 MB-FIX    9 CALLOG   10 VACANT   |
|     |         |  11 FWD      12 LNR                                          |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA1  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA2  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA3  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA4  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
+-----+---------+--------------------------------------------------------------+
AMO-TAPRO-111       PROGRAMMABLE KEY DEFINITION FOR DIGITAL TERMINALS           
DISPLAY COMPLETED;  
Sample standard key layouts for CP400/ CP600 variants:
 <DIS-TAPRO:TYPE=STD,STD=110&&111;
DIS-TAPRO:TYPE=STD,STD=110&&111;
H500:  AMO TAPRO STARTED
+-----+---------+--------------------------------------------------------------+
| STD | DIGTYP  | "SERVICE INFORMATION"          KEY LAYOUT                    |
+-----+---------+--------------------------------------------------------------+
| 110 | CP400   |  "                                                  "        |
|     |         |   1 SPKR-FIX  2 HS-FIX    3 MUTE-FIX  4 FIX       5 FIX      |
|     |         |   6 FIX       7 CH-FIX    8 FIX       9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT   17 FIX      18 FIX      19 FWD-FIX  20 FIX      |
|     |         |  21 FIX      22 FIX      23 FIX      24 FIX      25 VACANT   |
|     |         |  26 VACANT   27 VACANT   28 VACANT   29 VACANT   30 VACANT   |
|     |         |  31 VACANT   32 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA1  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT                                                   |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA2  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT                                                   |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA3  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT                                                   |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA4  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT                                                   |
+-----+---------+--------------------------------------------------------------+
| 111 | CP600   |  "                                                  "        |
|     |         |   1 SPKR-FIX  2 HS-FIX    3 MUTE-FIX  4 FIX       5 FIX      |
|     |         |   6 FIX       7 CH-FIX    8 FIX       9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT   17 FIX      18 FIX      19 FWD-FIX  20 FIX      |
|     |         |  21 FIX      22 FIX      23 FIX      24 FIX      25 VACANT   |
|     |         |  26 VACANT   27 VACANT   28 VACANT   29 VACANT   30 VACANT   |
|     |         |  31 VACANT   32 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA1  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA2  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA3  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA4  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
+-----+---------+--------------------------------------------------------------+
AMO-TAPRO-111       PROGRAMMABLE KEY DEFINITION FOR DIGITAL TERMINALS           
DISPLAY COMPLETED;
Sample standard key layouts for CP700 variant:
<DISPLAY-TAPRO:TYPE=STD,STD=113;
DISPLAY-TAPRO:TYPE=STD,STD=113;
H500:  AMO TAPRO STARTED
+-----+---------+---------------------------------------------------------------+
| STD | DIGTYP  | "SERVICE INFORMATION"          KEY LAYOUT                     |
+-----+---------+---------------------------------------------------------------+
| 113 | CP700   |  "DESKPHONE CP700                                   "         |
|     |         |   1 SPKR-FIX  2 HS-FIX    3 MUTE-FIX  4 TRANS-FIX  5 HOLD-FIX |
|     |         |   6 CONF-FIX  7 CH-FIX    8 MB-FIX    9 VACANT    10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT    15 VACANT   |
|     |         |  16 VACANT   17 FIX      18 FIX      19 FIX       20 FIX      |
|     |         |  21 FIX      22 FIX      23 FIX      24 FIX       25 VACANT   |
|     |         |  26 VACANT   27 VACANT   28 VACANT   29 VACANT    30 VACANT   |
|     |         |  31 VACANT   32 VACANT                                        |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - -+
|     | OPTIA1  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT    |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT    |
|     |         |  11 VACANT   12 VACANT                                        |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - -+
|     | OPTIA2  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT    |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT    |
|     |         |  11 VACANT   12 VACANT                                        |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- -+
|     | OPTIA3  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT    |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT    |
|     |         |  11 VACANT   12 VACANT                                        |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- -+
|     | OPTIA4  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT    |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT    |
|     |         |  11 VACANT   12 VACANT                                        |
+-----+---------+---------------------------------------------------------------+
AMO-TAPRO-111       PROGRAMMABLE KEY DEFINITION FOR DIGITAL TERMINALS           
DISPLAY COMPLETED;
Sample standard key layouts for CP110 variant:
DISP-TAPRO:STD,114;
H500:  AMO TAPRO STARTED
+-----+---------+--------------------------------------------------------------+
| STD | DIGTYP  | "SERVICE INFORMATION"          KEY LAYOUT                    |
+-----+---------+--------------------------------------------------------------+
| 114 | CP110   |  "DESKPHONE CP110                                   "        |
|     |         |   1 SPKR-FIX  2 HS-FIX    3 MUTE-FIX  4 FIX       5 FIX      |
|     |         |   6 FIX       7 CH-FIX    8 MB-FIX    9 VACANT   10 VACANT   |
|     |         |  11 VACANT                                                   |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA1  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA2  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA3  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA4  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT                                       |
+-----+---------+--------------------------------------------------------------+

AMO-TAPRO-111       PROGRAMMABLE KEY DEFINITION FOR DIGITAL TERMINALS           
DISPLAY COMPLETED;
Sample standard key layouts for CP410 variant:
DISP-TAPRO:STD,115;
H500:  AMO TAPRO STARTED
+-----+---------+--------------------------------------------------------------+
| STD | DIGTYP  | "SERVICE INFORMATION"          KEY LAYOUT                    |
+-----+---------+--------------------------------------------------------------+
| 115 | CP410   |  "DESKPHONE CP410                                   "        |
|     |         |   1 SPKR-FIX  2 HS-FIX    3 MUTE-FIX  4 TRNS-FIX  5 HOLD-FIX |
|     |         |   6 CONF-FIX  7 CH-FIX    8 MB-FIX    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT   17 FIX      18 FIX      19 FWD-FIX  20 FIX      |
|     |         |  21 FIX      22 FIX      23 FIX      24 FIX      25 VACANT   |
|     |         |  26 VACANT   27 VACANT   28 VACANT   29 VACANT   30 VACANT   |
|     |         |  31 VACANT   32 VACANT                                       |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA1  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT                                                   |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA2  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT                                                   |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA3  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT                                                   |
|     + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
|     | OPTIA4  |   1 VACANT    2 VACANT    3 VACANT    4 VACANT    5 VACANT   |
|     |         |   6 VACANT    7 VACANT    8 VACANT    9 VACANT   10 VACANT   |
|     |         |  11 VACANT   12 VACANT   13 VACANT   14 VACANT   15 VACANT   |
|     |         |  16 VACANT                                                   |
+-----+---------+--------------------------------------------------------------+

AMO-TAPRO-111       PROGRAMMABLE KEY DEFINITION FOR DIGITAL TERMINALS           
DISPLAY COMPLETED;
The values CP100, CP110, CP200, CP400, CP410, CP600, and CP700 also apply in AMO TAPRO for the DIGTYP parameter.
  • OpenScape Desk Phone CP100/CP110 HFA
    The OpenScape Desk Phone CP100, CP110 have three programmable function keys (9,10,11) which can be re-programed with different functions or phone numbers at any time.
  • OpenScape Desk Phone CP200/ CP210 HFA
    The OpenScape Desk Phone CP200, CP210 HFA has four freely programmable keys (9,10,11,12), which are preassigned by default in the standard key layout with the functions Call log, Not assigned, Forwarding key and Last number redial.
  • OpenScape Desk Phone CP400
    The OpenScape Desk Phone C400 HFA has sixteen freely programmable keys (9 - 16 and 25 - 32). In addition, the terminal has four keys on the right side of the display, called softkeys, which can be used to select the respective menu options in the bottom row of the display.
  • OpenScape Desk Phone CP600/ CP410
    The OpenScape Desk Phone C600, CP410 HFA has sixteen freely programmable keys (9 - 16 and 25 - 32) with electronic key labeling. In addition, the terminal has five keys on the right side of the display, called softkeys, which can be used to select the respective menu options in the bottom row of the display.
  • OpenScape Desk Phone CP700/ CP710
    The OpenScape Desk Phone C700, CP710 HFA has sixteen freely programmable keys (9 - 16 and 25 - 32) with electronic key labeling.
    In addition, the terminal has 12 free programmable keys with LED called softkeys. The first 6 programmable keys are permanently displayed on the left panel. The last 6 programmable keys are available in Favorites.
IMPORTANT:
The key functions of the softkeys are only assigned in the (local) terminal and therefore cannot be either administered or queried via AMO.
INFO:
The OpenScape Desk Phone CP700/CP700X includes the REDIAL KEY, which can be configured through WBM.
Key values
The logical key values for Keymodules are the following.
 
MAIN DEVICE
DSS1
DSS2
DSS3
DSS4
Layer 1
1 - 32
33-48
49-64
65-80
81-96
Layer 2
180-211
97-112
113-128
129-144
145-160
INFO: