each CMI BASE station (configured via ADD-SBCSU) increment TDM counter by 4
|
|
•
|
the following digital devices (configured via ADD-SBCSU) increment the TDM counter by 1 (qualified by the “device type” parameter in the AMO command): KEY300, SET500, SET600, SET700, OPTISET, S0PP. Furthermore, extension boards (CBUSEXP, MBUSEXP, OPTIEXP) increment the TDM counter by 1 likewise.
|
|
•
|
the following digital devices (configured via ADD-SBCSU) increment the TDM counter by 2 (qualified by the “device type” parameter in the AMO command): SET500&, SET600&, SET700&, OPTISET&
|
|
•
|
a primary rate interface (configured via ADD-SBCSU, “device type” parameter “S2PP”) increments the TDM counter by 30
|
|
•
|
the virtual devices (VIRTDTE configured via ADD-SBCSU) and SIGNOFF devices (changed on BCSU or SBCSU level) are license free
|
|
•
|
|
•
|