60.3
Parameter Description
ANNDIAL
Time until announcement for dial.
Type of Input
:
single value, optional
Possible Values
:
5 - 120 sec
Default Value
:
5 sec
ANSADV
No answer advance:
Timer for call forwarding - no answer
Type of Input
:
single value, optional
Possible Values
:
3 - 3600 sec
Default Value
:
20 sec
AOCT1
Answer supevision of charge request
Type of Input
:
single value, optional
Possible Values
:
2 - 99 sec
Default Value
:
15 sec
AOCT2
Answer supervision of get final charge
Type of Input
:
single value, optional
Possible Values
:
2 - 99 sec
Default Value
:
15 sec
ATDLYANN
Synchronous announcement on attendant console:
The timer controls the internal tone switches within a announcement cycle.
Type of Input
:
single value, optional
Possible Values
:
1 - 60 sec
Default Value
:
12 sec
ATNDCALL
Attendant call:
If a call is not answered by an attendant within this time period, it is automatically night-switched and the call is returned to the call queuer.
The timer is started only if the station is not in the conversation state.
Type of Input
:
single value, optional
Possible Values
:
10 - 90 sec
Default Value
:
60 sec
ATNDCQ
Attendant call queue:
Timer for periodically updating the display of waiting calls on the screen at the attendant position. Call is returned to the general attendant.
Type of Input
:
single value, optional
Possible Values
:
1 - 10 sec
Default Value
:
2 sec
ATNDDIS
Attendant display:
Warm-up time for the screen at the attendant position after it is turned on/or headset jack is inserted. The attendant position can only be seized outgoing during this time.
Type of Input
:
single value, optional
Possible Values
:
5 - 60 sec
Default Value
:
20 sec
ATNDHOLD
Attendant hold:
Time period after unplugging the attendant position jack for which on-hold/parked calls at the attendant position are retained for re-interrogation after plugging the jack back in. If the timer expires and the jack is not plugged back in, these calls are lost.
Type of Input
:
single value, optional
Possible Values
:
3 - 10 sec
Default Value
:
5 sec
ATNDTNSR
Frequency of setup message (busy trunk night service):
This timer is used to control the repeat frequency of the SETUP messagees sent to a busy individual night service destination.
Type of Input
:
single value, optional
Possible Values
:
3 - 100 sec
Default Value
:
7 sec
ATNDTRNS
Transfer to attendant:
This timer is used for the following two functions:
1. Time after which a parallel call to the attendant position is to be made after ringing has been sent to an idle station which does not answer.
2. Time after which trunk calls in the call queuer will be indicated by rapid flashing of the overload LED. The overload indicator must have been activated using AMO
ZAND
(TYPE=ALLDATA, ACOVLT=YES).
Type of Input
:
single value, optional
Possible Values
:
5 - 3600 sec
Default Value
:
30 sec
AUTOTONE
"ON" time for answer tone on SLMA
(answering device for comp.-controlled call setup).
Type of Input
:
single value, optional
Possible Values
:
100 - 999 ms
Default Value
:
200 ms
AUTCMPON
auto camp on timer.
Type of Input
:
single value, optional
Possible Values
:
1- 60 sec
Default Value
:
5 sec
CBK
Time after which a recall is to be stopped (Call back).
This timer will be used even for Recall Time T-CCBS3..
Type of Input
:
single value, optional
Possible Values
:
10 - 100 sec
Default Value
:
20 sec
CBMBDANS
response time of the particular LTUCC board.
Type of Input
:
single value, optional
Possible Values
:
1 - 300 sec
Default Value
:
30 sec
CBMNXTBD
control timer for checking the LTUCC boards.
Type of Input
:
single value, optional
Possible Values
:
2 - 30 min
Default Value
:
20 min
CBRLEN
Ringing time for callback notification:
Only applies, if the parameter RNGBKTN is declared in the TYPE=ALLDATA branch of the AMO
ZAND
, if called party is free but does not answer.
Type of Input
:
single value, optional
Possible Values
:
10 - 120 sec
Default Value
:
40 sec
CCBS5
Supervision Timer for callback TSC;
Controlling of receipt UUS3 messages per time unit (Congestion_Control_Timer)
Type of Input
:
Single value, optional
Possible Values
:
1 - 7200 sec.
Default Value
:
3600 sec.
CDRDISDE
Cancel display of call charges for CDISP (call detail display at DIGITE):
The timer regulates the time which the display remains on the digite screen after the station becomes idle.
Type of Input
:
single value, optional
Possible Values
:
3 - 300 sec
Default Value
:
10 sec
CLRANS1
Clear-answer time 1 allowed before cancelling search:
If mode of operation DELANS (cancel the job only when answered) for the code calling system the search job is cancelled after the timer has expired, at the latest. Four timers, each with differing default values, are provided. These default values are assigned by means of AMO
TSCSU
(parameter DELANS2).
Type of Input
:
single value, optional
Possible Values
:
20 - 600 sec
Default Value
20 sec
CLRANS2
Clear-answer time 2 allowed before cancelling search:
If mode of operation DELANS (cancel the job only when answered) for the code calling system the search job is cancelled after the timer has expired, at the latest. Four timers, each with differing default values, are provided. These default values are assigned by means of AMO
TSCSU
(parameter DELANS2).
Type of Input
:
single value, optional
Possible Values
:
20 - 600 sec
Default Value
:
30 sec
CLRANS3
Clear-answer time 3 allowed before cancelling search:
If mode of operation DELANS (cancel the job only when answered) for the code calling system the search job is cancelled after the timer has expired, at the latest. Four timers, each with differing default values, are provided. These default values are assigned by means of AMO
TSCSU
(parameter DELANS2).
Type of Input
:
single value, optional
Possible Values
:
20 - 600 sec
Default Value
:
50 sec
CLRANS4
Clear-answer time 4 allowed before cancelling search:
If mode of operation DELANS (cancel the job only when answered) for the code calling system the search job is cancelled after the timer has expired, at the latest. Four timers, each with differing default values, are provided. These default values are assigned by means of AMO
TSCSU
(parameter DELANS2).
Type of Input
:
single value, optional
Possible Values
:
20 - 600 sec
Default Value
:
120 sec
CQOFL
Overflow Timer;
when this timer has expired, the call shall overflow to the overflow destination.
Type of Input
:
Single value, optional
Possible Values
:
5 - 240 sec.
Default Value
:
30 sec.
CQPRIO
Priority Timer;
when this timer has expired, the priority level of the concerned call has to be increased.
Type of Input
:
Single value, optional
Possible Values
:
5 - 240 sec.
Default Value
:
15 sec.
CTHLDREC
Timer to control the duration of a Manual Hold of a call
Type of Input
:
Single value, optional
Possible Values
:
10 - 3600 sec.
Default Value
:
300 sec.
CTLS1
Controlled trunk and line selection timer 1
Type of Input
:
Single value, optional
Possible Values
:
0 - 300 sec.
Default Value
:
2 sec.
CTLS2
Controlled trunk and line selection timer 2
Type of Input
:
Single value, optional
Possible Values
:
0 - 300 sec.
Default Value
:
2 sec.
DANNDIAL
Duration of announcement for dial.
Type of Input
:
single value, optional
Possible Values
:
5 - 180 sec
Default Value
:
15 sec
DCIEOD
End-of-dial supervision when setting up a trunk call or a tie-trunk call for a DCI from an associated ANATE or DIGITE.
Type of Input
:
single value, optional
Possible Values
:
3 - 9 sec
Default Value
:
5 sec
DCPA1
Directed call park - park destination is idle.
Type of Input
:
single value, optional
Possible Values
:
1 - 999 sec
Default Value
:
10 sec
DCPA2
Directed call park - recall timer of the parked party.
Type of Input
:
single value, optional
Possible Values
:
1 - 999 sec
Default Value
:
15 sec
DCPA3
Directed call park - park destination is busy.
Type of Input
:
single value, optional
Possible Values
:
1 - 999 sec
Default Value
:
10 sec
DISPCH
Time between actualization of charge display:
Actualization of charge display at station by desired interval. The adjusted value is only an approximate value which can be exceeded when the switching unit is hardly working to capacity by processes of high priority.
The parameter is only effective if charges will really be displayed.
Type of Input
:
single value, optional
Possible Values
:
10 - 300 sec
Default Value
:
20 sec
ECCSSUPV
External computer controlled call setup (ECCS) supervision time.
Type of Input
:
single value, optional
Possible Values
:
1 - 255 sec
Default Value
:
15 sec
FAXCD
After the code FAX is dialed from a digite, the timer starts during a call (while in the call state). If no DN is dialed, a FAX call is set up to the other party after the timer expires if the other party has a FAX device.
Type of Input
:
single value, optional
Possible Values
:
1 - 9 sec
Default Value
:
5 sec
FAXOFLPM
Fax overflow time to PhoneMail:
The time before the overflow to PhoneMail takes place in the case "no answer"
Type of Input
:
single value, optional
Possible Values
:
1 - 999 sec
Default Value
30 sec
FTRQTOUT
Final Tones:
i.e busy, reorder etc. that require timeout
Type of Input
:
single value, optional
Possible Values
:
5 - 3600 sec
Default Value
10 sec
FTWOTOUT
Final Tones that do not
require timeout
Type of Input
:
single value, optional
Possible Values
:
5 - 3600 sec
Default Value
180 sec
FWDDESK
NO ANSWER ADVANCE TIMER FROM CLIENT TO DESKPHONE CIRCUIT
Type of Input
single value, group member
Possible Values
numeric, 1-30
FWDCELL
NO ANSWER ADVANCE TIMER FROM DESK TO MOBILE FOR OSMO&CIRCUIT
Type of Input
single value, group member
Possible Values
numeric, 1-30
FWDVM
NO ANS ADV TIMER TO VM FOR OSMO & TO CFNR DEST FOR CIRCUIT
Type of Input
single value, group member
Possible Values
numeric, 1-30
FWDCFNR
NO ANSWER ADVANCE TIMER FOR OSMO ONLY
Type of Input
single value, group member
Possible Values
numeric, 1-30
GPUNST
Network-wide group pick-up tsc teardown timer
Type of Input
:
single value, optional
Possible Values
:
60 - 64800 sec
Default Value
180 sec
GWNAVAIL
Time during a gateway is marked as not reachable
Type of Input
:
single value, optional
Possible Values
:
1 - 300 sec
Default Value
60 sec
KNLEN
Length of knocking signal for DID calls from CO.
Type of Input
:
single value, optional
Possible Values
:
10 - 120 sec
Default Value
:
30 sec
LCREOD
LCR (least cost routing) end-of-dial timer:
This timer is restarted after each digit dialed. Upon expiry of the timer, it is assumed that dialing has been completed.
Type of Input
:
single value, optional
Possible Values
:
3 - 30 sec
Default Value
:
10 sec
LCRET
Expensive route tone supervison.
Type of Input
:
single value, optional
Possible Values
:
2 - 10 sec
Default Value
:
5 sec
LONGPATH
Reserve long path (multi-mts (stage) system only):
Timer for delayed release of the long route via CSN (for systems with a 3-stage switching network).
Type of Input
:
single value, optional
Possible Values
:
1 - 5 sec
Default Value
:
2 sec
NEWCONN
Supervision time for new connection request:
supervision of a new connection setup.
Type of Input
:
single value, optional
Possible Values
:
0 - 300 sec
Default Value
110 sec
NIRECALL
night recall timer
Type of Input
:
single value, optional
Possible Values
:
60 - 1800 sec
Default Value
900 sec
NOANSCON
No answer consultation:
The timer is set for a trunk which recalls to the initiator when the transfer was not successful. If the initiator does not answer, the call is forwarded on to the attendant after the timer expires.
Type of Input
:
single value, optional
Possible Value
:
5 - 3600 sec
Default Value
:
30 sec
NOCALLTR
No call transfer:
Ringing time in the case of a transfer to an available subscriber, or checking time in the case of a transfer to a busy subscriber. After the timer expires, the initiator is recalled and timer "NOANSCON" is started.
Type of Input
:
single value, optional
Possible Values
:
5 - 3600 sec
Default Value
:
30 sec
NOTRDY1
Time after which the the input of search jobs is negatively acknowledged if the TCOM (multi-purpose outgoing trunk circuit for special equipment) is "out of service".
Type of Input
:
single value, optional
Possible Values
:
1 - 5 sec
Default Value
:
3 sec
NOTRDY2
Time after which the the input of search jobs is negatively acknowledged if the TCOM (multi-purpose outgoing trunk circuit for special equipment) is "out of service".
Type of Input
:
single value, optional
Possible Values
:
5 - 10 sec
Default Value
:
6 sec
NOTRNG
Periodical repeated notification ring
Type of Input
:
single value, optional
Possible Values
:
5 - 30 sec
Default Value
:
5 sec
OFLPM
AC queue overflow to phonemail:
The timer will be started on entering the incoming CO trunk call into the AC queue if this function is activated.
Type of Input
:
single value, optional
Possible Values
:
1 - 999 sec
Default Value
:
20 sec
ONHOOK
Time between deactivation and B-station going on-hook (1TR6).
Type of Input
:
single value, optional
Possible Values
:
10 - 60 min
Default Value
:
15 min
PARK
Time for callback in the case of a parked subscriber, park unit/location is released.
Type of Input
:
single value, optional
Possible Values
:
10 - 3600 sec
Default Value
:
30 sec
PINNV1
Time for validation of the pin, of COPIN 1 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=1,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
1800 sec
PINNV2
Time for validation of the pin, of COPIN 2 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=2,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
1800 sec
PINNV3
Time for validation of the pin, of COPIN 3 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=3,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
1800 sec
PINNV4
Time for validation of the pin, of COPIN 1 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=4,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
1800 sec
PINNV5
Time for validation of the pin, of COPIN 1 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=5,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
1800 sec
PINNV6
Time for validation of the pin, of COPIN 1 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=6,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
1800 sec
PINNV7
Time for validation of the pin, of COPIN 7 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=7,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
1800 sec
PINNV10
Time for validation of the pin, of COPIN 10 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=10,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
1800 sec
PINNV11
Time for validation of the pin, of COPIN 11 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=11,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
1800 sec
PINNV12
Time for validation of the pin, of COPIN 12 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=12,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
1800 sec
PINNV13
Time for validation of the pin, of COPIN 13 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=13,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
1800 sec
PINNV14
Time for validation of the pin, of COPIN 14 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=14,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
1800 sec
PINNV15
Time for validation of the pin, of COPIN 15 for non-voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=15,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
1800 sec
PINVO1
Time for validation of the pin, of COPIN 1 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=1,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
300 sec
PINVO2
Time for validation of the pin, of COPIN 2 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=2,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
300 sec
PINVO3
Time for validation of the pin, of COPIN 3 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=3,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
300 sec
PINVO4
Time for validation of the pin, of COPIN 4 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=4,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
300 sec
PINVO5
Time for validation of the pin, of COPIN 5 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=5,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
300 sec
PINVO6
Time for validation of the pin, of COPIN 6 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=6,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
300 sec
PINVO7
Time for validation of the pin, of COPIN 7 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=7,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
1 - 64800 sec
Default Value
:
300 sec
PINVO10
Time for validation of the pin, of COPIN 10 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=10,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
300 sec
PINVO11
Time for validation of the pin, of COPIN 11 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=11,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
300 sec
PINVO12
Time for validation of the pin, of COPIN 12 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=12,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
300 sec
PINVO13
Time for validation of the pin, of COPIN 13 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=13,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
300 sec
PINVO14
Time for validation of the pin, of COPIN 14 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=14,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
300 sec
PINVO15
Time for validation of the pin, of COPIN 15 for voice, if pin has not been deactivated
(see AMO
PERSI
, CHANGE TYPE=COPIN,COPIN=15,PINDUR=TIME).
Type of Input
:
single value, optional
Possible Values
:
0 - 64800 sec
Default Value
:
300 sec
PREDCALL
timer for making predictive call attempt.
Type of Input
:
single value, optional
Possible Values
:
3-255 sec
Default Value
:
20 sec
PREEMT
Preemption: Higher-order deactivation timer for releasing outgoing calls if no-one answers a callback (due to call charge pulses).
Type of Input
:
single value, optional
Possible Values
:
90 - 240 sec
Default Value
:
90 sec
PRREQC
Supervision time of state PR-REQ-COMPLETING:
supervision, if the old way will be released without errors.
Type of Input
:
single value, optional
Possible Values
:
0 - 300 sec
Default Value
15 sec
PRREQI
Supervision time of state PR-REQ-INITIATED:
supervision, if there is an answer from Cooperating PTNX.
Type of Input
:
single value, optional
Possible Values
:
0 - 300 sec
Default Value
30 sec
RECALL
Recall transfering party:
Timer for recall if a subscriber is transferred and and subscriber does not answer after the transfer (or checking time if the transfer is to a busy subscriber).
Type of Input
:
single value, optional
Possible Values
:
5 - 3600 sec
Default Value
:
30 sec
RECNIGHT
Max. automatic recall time for night station:
the timer will be started if there is a call-back for incoming co and if the waiting co trunk will be set for call state. The timer is also used for maximum duration of the calls in ringing state that are not queued to ACD. If the release destination doesn´t answer the connection will be released after timing.
Remark: for analog trunk boards (e.g. TMANI, TMANIN), the connection release will depend on either the Central Office or on the caller.
Type of Input
:
single value, optional
Possible Values
:
10 - 64800 sec
Default Value
:
180 sec
RECPARK
Max. park time of trunk calls before recall to attendant.
Type of Input
:
single value, optional
Possible Values
:
10 - 64800 sec
Default Value
:
120 sec
RELCON
Release Timeout, if the feature RELEASE CONTROL is implemented (e.g. China):
This is the time before a connection is released after an user has gone on-hook. During this time the remaining user can dial a suffix code (RERING) in order to keep theconnection.
Type of Input
:
single value, optional
Possible Values
:
5 - 300 sec
Default Value
:
90 sec
RELREC
Release timer after incoming traffic recall (e.g. Austria):
Whether the parameter is used by CP is determined by the COT, parameter BRAR (back release after recall).
Type of Input
:
single value, optional
Possible Values
:
90 - 340 sec
Default Value
:
90 sec
RELJOIN
release trunks after join.
Type of Input
:
single value, optional
Possible Values
:
1 - 999 sec
Default Value
:
900 sec
REPAUSE
repdial pause timer.
Type of Input
:
single value, optional
Possible Values
:
1 - 60 sec
Default Value
:
3 sec
ROUTEREQ
Wait for ACL route request:
In ACD-ACL if a route request is sent to the application, then the application response timer is set unless the Delay Ringback timer is of equal or shorter duration. Any response received from the application or the expiration of the Delay Ringback timer will clear the application response timer (if it is running).
Type of Input
:
single value, optional
Possible Values
:
5 - 35 sec
Default Value
:
5 sec
RPTSZ
Repeat seizure:
If, in the case of an external call, the general attendant is seized, a new seizure message is sent after the timer expires.
Type of Input
:
single value, optional
Possible Values
:
3 - 10 sec
Default Value
:
5 sec
RPTSZEND
Repeat seizure end:
If an external party calls the attendant via CAC EXTERNAL and if this call has not arrived at the destination station after timeout, the call will be forwarded to the highest configured AC group.
Type of Input
:
single value, optional
Possible Values
:
1 - 300 sec
Default Value
:
40 sec
RTAD
time for validation of LCR route advanced
Type of Input
:
single value, optional
Possible Values
:
0-15 sec
Default Value
:
0 sec
SMPFTIME
Waiting Time For
Mobile Phone Response
Type of Input
Single Value, Optional
Possible Value
2-30 sec
Default Value
8 sec
SPDPD
Speed call post dialing:
Timer for manual suffix dialing when the speed dialer is used. After the timer expires, the stored suffix dialing code (parameter SUPDIAL in AMO
ZRNGZ
) is automatically sent.
Type of Input
:
single value, optional
Possible Values
:
3 - 10 sec
Default Value
:
5 sec
The value of SPDPD must be smaller than the value of parameter EOD1A of AMO
DTIM2
The value of SPDPD must be smaller than the value of LCREOD if SPEED DIALING with AUTOMATIC SUFFIX DIALING is used.
SYSRCPAR
system park recall timer
Type of Input
:
single value, optional
Possible Values
:
10-3600 sec
Default Value
:
30 sec
T400
timer for national ISDN bridge.
Type of Input
:
single value, optional
Possible Values
:
16-24 sec
Default Value
:
20 sec
TRKTOTRK
Trunk to trunk supervision timer.
Type of Input
:
single value, optional
Possible Values
:
60-1800 sec
Default Value
:
120 sec
TSUPVAUT
After timeout, callback will be automatically initiated.
Type of Input
:
single value, optional
Possible Values
:
5 - 60 sec
Default Value
:
30 sec
TSUPVCB
Timeout supervision for callback to A-station:
Timer only applies within the network.
Type of Input
:
single value, optional
Possible Values
:
1 - 25 sec
Default Value
:
2 sec
TYPESWU
Branch parameter, desired timer category.
Type of Input
:
single value, required
Possible Values
:
ATND (ATTENDANT TIMERS)
CCM (MULTIPLE SEARCH CODE CALLING TIMERS)
CP (CALL PROCESSING TIMERS)
TRK (TRUNK TIMERS)
VECOTIME (VECO TIMERS)
USERGD2
User guide for check and store displays on digite:
Timer for the duration of additional displays on the screen.
Type of Input
:
single value, optional
Possible Values
:
1 - 5 sec
Default Value
:
2 sec
USERGD5
User guide for check and store displays on digite:
Timer for the duration of additional displays on the screen.
Type of Input
:
single value, optional
Possible Values
:
3 - 15 sec
Default Value
:
5 sec
UUS3T1
Timer for UUS3 Request started on called network;
the timer will be started on receiption of FACILITY message.
Type of Input
:
Single value, optional
Possible Values
:
1 - 60 sec.
Default Value
:
10 sec.
UUS3T2
Timer for UUS3 Info message started on net side;
peroid of time for number of user messages
Type of Input
:
Single value, optional
Possible Values
:
1 - 60 sec.
Default Value
:
10 sec.
UUS3T3
Timer for UUS3 Request started on calling USER;
the timer will be started on receiption of FACILITY message.
Type of Input
:
Single value, optional
Possible Values
:
1 - 60 sec.
Default Value
:
10 sec.
UUS3T3N
Timer for UUS3 Request started on calling USER national depending;
the timer will be started on receiption of FACILITY message.
Type of Input
:
Single value, optional
Possible Values
:
1 - 60 sec.
Default Value
:
10 sec.
VARDIALT
Various Dial Times.
Type of Input
:
single value, optional
Possible Values
:
5 - 3600 sec..
Default Value
:
20 sec.
WAIT1
Time for dummy task 1 (enhanced code calling):
This time will be assigned by the AMO
TSCSU
when TCOM (mult.-purpose outgoing trunk circuit for special equipment) is created for PSM (multiple code calling system).
Type of Input
:
single value, optional
Possible Values
:
500 - 30000 ms..
Default Value
:
1000 ms.
WAIT2
Time for dummy task 2 (enhanced code calling):
This time will be assigned by the AMO
TSCSU
when TCOM (mult.-purpose outgoing trunk circuit for special equipment) is created for PSM (multiple code calling system).
Type of Input
:
single value, optional
Possible Values
:
500 - 30000 ms..
Default Value
:
2000 ms.
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025