112.3
Parameter Description
AMOUNTLT
Call amount unit limit *
Type of Input
:
Single value, optional
Possible Values
:
max. 8 digits, 0 to 9
Default Value
:
0
CALLT
Call duration limit, Input hhmmss
Note:
Not for internal connections
Type of Input
:
Single value, optional
Possible Values
:
000001 to 181215
Default Value
:
181215 (= 65535 sec. = H’FFFF)
CARRIER
Number of carrier of a connection
Type of Input
:
Single value, optional
required (ADD, CHANGE)
Possible Values
:
0 to 9
CDRCODE
Route Code (dialed number prefix)
(see AMO-
RCUT
)
Type of Input
:
Single value, optional
Possible Values
:
max. 6 digits, 0 to 9
CDRULT
Call charge unit limit
Type of Input
:
Single value, optional
Possible Values
:
0 to 4000
Default Value
:
4000
HOURLIM
Hour value to fixed time-of-day, Input: hh
Type of Input
:
Single value, optional
Possible Values
:
0 to 23, or no input, if no fixed time-of-day
LTTYPE
Limit type
Type of Input
:
Single value, optional
Possible Values
:
AMOUNT
= Call amount unit limit
CHRG
= Call charge unit limit
TIME
= Call duration limit
TBL
Designation of table
Type of Input
:
Single value, optional
required (ADD, CHANGE)
Possible Values
:
CAR
= Carrier
HOUR
= Hour limit
RCD
= Routing code
* The explanation of the amount units see appendix in description for AMO-
TTBL
.
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.