The status of all modules, trunks, devices and SERVERs is stored in the memory of COMMON CONTROL (CC). The AMO SDSU (Status Display of Switching Unit) is used to obtain a status overview of all modules, trunks and devices of the SWU, as well the overall status of the SERVER.
The AMO runs in the active side of the COMMON CONTROL.
This AMO description is valid beginning with HICOM UNITY 1.0.
None
| DISPLAY | password class 0 |
| DISPLAY-SDSU | [STATUS=<param>], [LINK=<param>], | |||||||||
| TYPE=UNIT,[PID=<param>]; | ||||||||||
| TYPE=GSNHWY,[PID=<param>], [HWY=<number>]; | ||||||||||
| TYPE=TSL,[LTG=<number>], [LTU=<number>], [HWY=<number>], [TSL=<number>]; | ||||||||||
| TYPE=PEN,LEVEL=<param>, [LTG=<number>], [LTU=<number>], [SLOT=<number>], [CCT=<number>]; | ||||||||||
| TYPE=LINE,LEVEL=<param>, [LTG=<number>], [LINE=<number>]; | ||||||||||
| TYPE=STNO,LEVEL=<param>, [STNO=<number>], [SVC=<param>]; | ||||||||||
| TYPE=TCSVR,[LTG=<number>], [LTU=<number>], [SLOT=<number>]; | ||||||||||
| TYPE=SVR; | ||||||||||
| TYPE=DIUC,[LTG=<number>], [LTU=<number>], [SLOT=<number>], [PCM=<number>]; | ||||||||||
The various possibilities for STATUS interrogation are:
The parameter STATUS combined with parameter LINK permits a selection of states to be output (see also chapter parameter description ):
Parameter LINK is relevant only in the first case if more then one status is input. There are cases, where ALL and SPEC produce completely different outputs. E.g. the circuits of a SIUP are put into operation by dependability (output READY at STATUS=SPEC), but are not connected with peripheral units (output NOGEN at STATUS=ALL).
After generating the empty data base, the AMO should not be started, as long, as the LTG is not on line. This could lead to a restart of the SWU. In split mode a start of the AMO should be avoided, because there is no connection from the standalone CC to the periphery. The concerning states therefore are not valid.
Sample Outputs: |
1. Non-operational states should be output for the central SWU modules (CC, LTG). The states READY, DEP, CP, RES and NOGEN & NPR will not be shown (no input for parameter STATUS). |
2. Display all states of the CC and central LTG modules. |
3. Search the entire SWU for a status; this status, however, is not set. |
4. Display all states of MTS modules with highway inputs of the first switching level. |
5. Display all states of the TSLs of HWY 58 - 69 for all LTUs. |
6. All states should be output for the Servers. |
7. Display every status of all peripheral modules (without trunks and devices) of LTG1/LTU2. |
8. As in Example 7, however now only the states READY & LOCK are to be output. The default value for a search link (parameter LINK) is "OR". That means that every module with status READY or LOCK is output. |
9. As in Example 8, however the search link (parameter LINK) for the states LOCK & AMO is now 'AND'. This means that only those modules are output for which a hard block has been performed with an AMO. |
10. From the module having the address LTG1/LTU1/SLOT97, those trunks should be output, which are out of service. |
11. As in Example 10, however, trunks and terminals, which are out of service, should be output. |
12. From the module with the address LTG1/LTU1/SLOT79, all modules, trunk and terminal states should be output. |
13. As in Example 12, however the only output is the status RBLK. |
14. From the module having the address LTG1/LTU1/SLOT61, all states of trunk 10 are displayed. |
15. All states of trunk 0 and the connected device shall be output by the module with address LTG1/LTU1/SLOT85. |
16. From a specific directory number range with service voice, the defective modules and trunks are displayed. |
17. For a specific STNO, service DTE and all states of modules, trunks and terminals are displayed. |
18. For a specific station number, the service FAX is defective. Interrogate module, trunk and terminal allocated to this service. |
19. For a specific line range, all states of modules and trunks are displayed. |
20. For a specific line, the states of module, trunk and device are displayed. |
21. For a DIUC64 the error states of the PCM paths are displyed. |
22. A MSN-call number and the related main call number shall be displayed. |
23. The status of all TC-Servers in the system shall be displayed. |
24. Display STATUS for STMA module on a specific PEN. |
25. As in Example 24, but only the states UNACH & NPR are to be output. |
26. The status of CBM modules on a LTUCC board on a specific PEN shall be displayed. |
27. The status of a local shelf (LS) LTU shall be displayed. |
DISPLAY-SDSU:,,UNIT;
SWU-CC (PART A / ACTIVE)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
H01: SPECIFIED STATUS NOT FOUND
LTG1 (PART A / ACTIVE)
-----
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
-LTUW---------SG 0 LTU 5 --------------------- NPR
-LTUW---------SG 0 LTU 6 --------------------- NPR
-LTUW---------SG 8 LTU 55 --------------------- UNACH
DISPLAY-SDSU:ALL,,UNIT,BP<G;
SWU-CC (PART A / ACTIVE)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
P101.C60 .CCD .058 DPC5 #Q2270-X READY
LTG1 (PART A / ACTIVE)
-----
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-LTUW---------SG 0 LTU 1 --------------------- READY
-LTUW---------SG 0 LTU 2 --------------------- READY
-LTUW---------SG 0 LTU 3 --------------------- READY
-LTUW---------SG 0 LTU 4 --------------------- READY
-LTUW---------SG 0 LTU 5 --------------------- NPR
-LTUW---------SG 0 LTU 6 --------------------- NPR
--------------SG 0 LTU 7 -WITH OVERLAY LTU 15- NPR
--------------SG 0 LTU 8 --------------------- NOGEN/NPR
--------------SG 0 LTU 9 --OVERLAY TO LTU 13-- NOGEN/NPR
--------------SG 0 LTU 10 --------------------- NOGEN/NPR
--------------SG 0 LTU 11 --------------------- NOGEN/NPR
--------------SG 0 LTU 12 --------------------- NOGEN/NPR
--------------SG 0 LTU 13 -WITH OVERLAY LTU 9- NPR
--------------SG 0 LTU 14 --------------------- NOGEN/NPR
--------------SG 0 LTU 15 --OVERLAY TO LTU 7-- NOGEN/NPR
-LTUW---------SG 8 LTU 55 --------------------- UNACH
P101.C60 1.CCD .070 QDCL #Q2113-X READY
PBC 1 --------------------- READY
PBC 2 --------------------- READY
PBC 3 --------------------- READY
PBC 4 --------------------- READY
HDLC 1 --------------------- READY
. . . .
HDLC 16 --------------------- READY
P101.C60 1.CCD .079 SICOE -SIU #Q2234-X READY
P101.C60 1.CCD .079 SICOE -CONF #Q2234-X READY
P101.C60 1.CCD .079 SICOE -MTS #Q2234-X READY
P101.C60 1.CCD .085 MTSCG -MTS #Q2224-X READY
P101.C60 1.CCD .085 MTSCG -PCG #Q2224-X
DISPLAY-SDSU:RES,,UNIT;
SWU-CC (PART A / ACTIVE)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
H01: SPECIFIED STATUS NOT FOUND
LTG1 (PART A / ACTIVE)
-----
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
H01: SPECIFIED STATUS NOT FOUND
DISPLAY-SDSU:ALL,,GSNHWY,LTG,35&&45;
LTG1 (PART A / ACTIVE)
-----
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
P101.C60 1.CCD .085 MTSCG -MTS #Q2224-X READY
HWY 35 --------------------- READY
HWY 36 --------------------- READY
HWY 37 --------------------- READY
HWY 38 --------------------- READY
HWY 39 --------------------- READY
HWY 40 --OVERLAY TO LTU 7-- READY
HWY 41 --OVERLAY TO LTU 7-- READY
HWY 42 --OVERLAY TO LTU 7-- READY
HWY 43 --OVERLAY TO LTU 7-- READY
HWY 44 --------------------- READY
HWY 45 --------------------- READY
DISPLAY-SDSU:ALL,,TSL,,,58&&69;
LTG1 (PART A / ACTIVE)
-----
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
-- LTU 7 -------- HWY 58 --------------------- READY
TSL 0 . . . . . . . . . . . READY
. . . .
TSL 31 . . . . . . . . . . . READY
-- LTU 7 -------- HWY 59 --------------------- READY
TSL 0 . . . . . . . . . . . READY
. . . .
TSL 31 . . . . . . . . . . . READY
-- LTU 8 -------- HWY 64 --------------------- READY
TSL 0 . . . . . . . . . . . READY
. . . .
TSL 31 . . . . . . . . . . . READY
-- LTU 8 -------- HWY 65 --------------------- READY
TSL 0 . . . . . . . . . . . READY
. . . .
TSL 31 . . . . . . . . . . . READY
-- LTU 8 -------- HWY 66 --------------------- READY
TSL 0 . . . . . . . . . . . READY
. . . .
TSL 31 . . . . . . . . . . . READY
-- LTU 8 -------- HWY 67 --------------------- READY
TSL 0 . . . . . . . . . . . READY
. . . .
TSL 31 . . . . . . . . . . . READY
-- LTU 9 -------- HWY 68 --OVERLAY ZU LTU 13-- READY
TSL 0 . . . . . . . . . . . READY
. . . .
TSL 31 . . . . . . . . . . . READY
-- LTU 9 -------- HWY 69 --OVERLAY ZU LTU 13-- READY
TSL 0 . . . . . . . . . . . READY
. . . .
TSL 31 . . . . . . . . . . . READY
-- CONF ----------- HWY 60 --------------------- READY
TSL 0 . . . . . . . . . . . READY
. . . .
TSL 31 . . . . . . . . . . . READY
-- CONF ----------- HWY 61 --------------------- READY
TSL 0 . . . . . . . . . . . READY
. . . .
TSL 31 . . . . . . . . . . . READY
DISPLAY-SDSU:ALL,,SVR;
SERVERS
-------
MODULE STATUS
A1 READY
DISPLAY-SDSU:ALL,,PEN,PER1,1,2;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-LTUW---------SG 0 LTU 2 --------------------- READY
P101.C60 1.LTU 2.019 RG Q2258-X NPR
P101.C60 1.LTU 2.025 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.031 SLMA A Q2157-X NPR
P101.C60 1.LTU 2.037 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.043 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.049 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.055 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.061 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.067 TMOM2 A Q2214-X NPR
P101.C60 1.LTU 2.073 LTUCE Q2248-X READY
P101.C60 1.LTU 2.079 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.085 TMOM2 A Q2214-X NPR
P101.C60 1.LTU 2.091 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.097 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.103 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.109 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.115 ........ .......... NOGEN/NPR
P101.C60 1.LTU 2.121 ........ .......... NOGEN/NPR
DISPLAY-SDSU:READY&LOCK,,PEN,PER1,1,2;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-LTUW---------SG 0 LTU 2 --------------------- READY
P101.C60 1.LTU 2.073 LTUCE Q2248-X READY
DISPLAY-SDSU:LOCK&AMO,AND,PEN,PER1,1,2;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
H01: SPECIFIED STATUS NOT FOUND
DISPLAY-SDSU:,,PEN,PER2,1,1,97;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
P101.C60 1.LTU 1.097 SLMO24 A Q2158-X NPR
SATZ LINE RUFNR SI BUSTYP
000 1162 OPTI ONLY UNACH
001 1163 OPTI ONLY UNACH
002 1164 OPTI FUNCT UNACH
. . . .
011 1173 OPTI FUNCT UNACH
012 1174 NOGEN
. . . .
023 1185 NOGEN
DISPLAY-SDSU:,,PEN,PER3,1,1,97;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
P101.C60 1.LTU 1.097 SLMO24 A Q2158-X NPR
CCT LINE STNO SI BUS TYPE
000 1162 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
001 SUBUNIT . . . . . KEYSYSTEM UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1366 STNO: 3500 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
CCT LINE STNO SI BUS TYPE
001 1163 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
001 SUBUNIT . . . . . KEYSYSTEM UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1367 STNO: 3507 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
CCT LINE STNO SI BUS TYPE
011 1173 OPTI FUNCT UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
001 SUBUNIT . . . . . KEYSYSTEM UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1390 STNO: 3559 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 ELEM DEV. . . . . SB FCT TERM UNACH/CP
(DTE )
LINE: 1390 STNO: 3559 SI: DTE
. .
. .
CCT LINE STNO SI BUS TYPE
012 1174 NOGEN
. . .
023 1185 NOGEN
DISPLAY-SDSU:ALL,,PEN,PER3,1,1,79;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-LTUW---------SG 0 LTU 1 --------------------- READY
P101.C60 1.LTU 1.079 SLMO A Q2144-X READY
CCT LINE STNO SI BUS TYPE
000 1118 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1341 STNO: 3100 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
001 1119 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1342 STNO: 3101 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
002 1120 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1343 STNO: 3102 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
003 1121 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . MAIN SEKR UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1344 STNO: 3103 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
004 . . . . . . . . DIGITE SUB A UNACH
005 . . . . . . . . DIGITE SUB A UNACH
006 . . . . . . . . DIGITE SUB A UNACH
007 . . . . . . . . DIGITE SUB A UNACH
008 . . . . . . . . DIGITE SUB A UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
004 1122 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . MAIN SEKR UNACH
(ALT_ROUT=N) (OPTISET ))
LINE: 1345 STNO: 3112 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
004 . . . . . . . . DIGITE SUB A UNACH
005 . . . . . . . . DIGITE SUB A UNACH
006 . . . . . . . . DIGITE SUB A UNACH
007 . . . . . . . . DIGITE SUB A UNACH
008 . . . . . . . . DIGITE SUB A UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
005 1123 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1346 STNO: 3113 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
006 1124 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1347 STNO: 3114 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
007 1125 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1348 STNO: 3115 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
008 1126 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1349 STNO: 3130 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
009 1127 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1350 STNO: 3149 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
010 1128 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . MAIN SEKR UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1351 STNO: 3150 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
004 . . . . . . . . DIGITE SUB A UNACH
005 . . . . . . . . DIGITE SUB A UNACH
006 . . . . . . . . DIGITE SUB A UNACH
007 . . . . . . . . DIGITE SUB A UNACH
008 . . . . . . . . DIGITE SUB A UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
011 1129 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . MAIN SEKR UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1352 STNO: 3151 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
004 . . . . . . . . DIGITE SUB A UNACH
005 . . . . . . . . DIGITE SUB A UNACH
006 . . . . . . . . DIGITE SUB A UNACH
007 . . . . . . . . DIGITE SUB A UNACH
008 . . . . . . . . DIGITE SUB A UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
012 1130 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1353 STNO: 3152 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
013 1131 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1354 STNO: 3153 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
014 1132 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1355 STNO: 3154 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
CCT LINE STNO SI BUS TYPE
015 1133 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1356 STNO: 3157 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
DISPLAY-SDSU:TRS,,PEN,PER3,1,1,79;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
H01: SPECIFIED STATUS NOT FOUND
DISPLAY-SDSU:ALL,,PEN,PER2,1,1,61,0;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-LTUW---------SG 0 LTU 1 --------------------- READY
P101.C60 1.LTU 1.061 WAML A Q2205-X NPR
CCT LINE STNO SI BUS TYPE
000 1117 NOGEN
DISPLAY-SDSU:ALL,,PEN,PER3,1,1,85,0;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-LTUW---------SG 0 LTU 1 --------------------- READY
P101.C60 1.LTU 1.085 TMBCT A Q2121-X WBT/UNACA
CCT LINE STNO SI BUS TYPE
015 1133 OPTI ONLY UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN UNACH
(ALT_ROUT=N) (OPTISET )
LINE: 1356 STNO: 3157 SI: VOICE
001 . . . . . . . . DIGITE SUB A UNACH
002 . . . . . . . . DIGITE SUB A UNACH
003 . . . . . . . . DIGITE SUB C UNACH
002 NO CONN
. .
008 NO CONN
DISPLAY-SDSU:,,STNO,PER2,3000&&3510;
STATION NUMBER ACCORDING TO PORT EQUIPMENT NUMBER
-------------------------------------------------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
P101.C60 1.LTU 1.079 SLMO A Q2144-X NPR
STNO INPUT CCT LINE STNO SI BUS TYPE
3100 000 1118 OPTI ONLY UNACH
3101 001 1119 OPTI ONLY UNACH
3102 002 1120 OPTI ONLY UNACH
3103 003 1121 OPTI ONLY UNACH
3112 004 1122 OPTI ONLY UNACH
3113 005 1123 OPTI ONLY UNACH
3114 006 1124 OPTI ONLY UNACH
3115 007 1125 OPTI ONLY UNACH
3130 008 1126 OPTI ONLY UNACH
H23: STNO 3142 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3143 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3144 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3145 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3146 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
3149 009 1127 OPTI ONLY UNACH
3150 010 1128 OPTI ONLY UNACH
3151 011 1129 OPTI ONLY UNACH
3152 012 1130 OPTI ONLY UNACH
3153 013 1131 OPTI ONLY UNACH
3154 014 1132 OPTI ONLY UNACH
3157 015 1133 OPTI ONLY UNACH
P101.C60 1.LTU 1.091 SLMO24 A Q2158-X NPR
STNO INPUT CCT LINE STNO SI BUS TYPE
3158 000 1138 OPTI ONLY UNACH
H23: STNO 3159 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3167 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3168 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3169 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3170 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3171 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3172 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3173 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3174 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3182 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
H23: STNO 3185 SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
3190 001 1139 OPTI ONLY UNACH
3191 002 1140 OPTI ONLY UNACH
3192 003 1141 OPTI ONLY UNACH
3193 004 1142 OPTI ONLY UNACH
3194 005 1143 OPTI ONLY UNACH
3195 006 1144 OPTI ONLY UNACH
3196 007 1145 OPTI ONLY UNACH
3197 008 1146 OPTI ONLY UNACH
P101.C60 1.LTU 1.097 SLMO24 A Q2158-X NPR
STNO INPUT CCT LINE STNO SI BUS TYPE
3500 000 1162 OPTI ONLY UNACH
3501 001 1163 OPTI ONLY UNACH
3502 002 1164 OPTI FUNCT UNACH
3503 003 1165 OPTI FUNCT UNACH
3508 004 1166 OPTI FUNCT UNACH
3509 004 1166 OPTI FUNCT UNACH
3510 005 1167 OPTI FUNCT UNACH
H18: AT BUSCONFIGURATIONS THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH PER3 !
DISPLAY-SDSU:ALL,,STNO,PER3,3513,DTE;
STATION NUMBER ACCORDING TO PORT EQUIPMENT NUMBER
-------------------------------------------------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
P102.C60 1.LTU 5.043 SLMQ A Q2153-X100 NPR/UNACH
STNO INPUT CCT LINE STNO SI BUS TYPE
3513 004 1291 OPTI FUNCT UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
004 ELEM DEV. . . . . SB FCT TERM UNACH/CP
(ALT_ROUT=N) (DTE )
LINE: 1375 STNO: 3513 SI: DTE
DISPLAY-SDSU:ALL,,STNO,PER3,3555,FAX;
STATION NUMBER ACCORDING TO PORT EQUIPMENT NUMBER
-------------------------------------------------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
P102.C60 1.LTU 5.043 SLMQ A Q2153-X100 NPR/UNACH
STNO INPUT CCT LINE STNO SI BUS TYPE
3555 004 1294 OPTI FUNCT UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
004 ELEM DEV. . . . . SB FCT TERM UNACH/CP
(FAX )
LINE: 1386 STNO: 3555 SI: FAX
DISPLAY-SDSU:ALL,,LINE,PER2,1,200&&231;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
** .LTG 1.LTU23.000 ........ .......... NOGEN/UNACH
LINE INPUT CCT LINE STNO SI BUS TYPE
200 013 200 NOGEN
201 014 201 NOGEN
202 015 202 NOGEN
** .LTG 1.LTU24.000 ........ .......... NOGEN/UNACH
LINE INPUT CCT LINE STNO SI BUS TYPE
203 000 203 NOGEN
204 001 204 NOGEN
. . . .
218 015 218 NOGEN
** .LTG 1.LTU25.000 ........ .......... NOGEN/UNACH
LINE INPUT CCT LINE STNO SI BUS TYPE
219 000 219 NOGEN
. . . .
231 012 231 NOGEN
DISPLAY-SDSU:ALL,,LINE,PER3,1,1396;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
P102.C60 1.LTU 5.031 SLMS A Q2117-X NPR/UNACH
LINE INPUT CCT LINE STNO SI BUS TYPE
1396 -> 002 1284 NUR FUNCT UNACH
MULTLINE 8. . . . . . . . . . . . . . .UNACH
001 ELEM DEV. . . . . SB FKT EG UNACH/CP
(SET600 )
LINE: 1396 RNR: 3574 SI: VOICE
002 ELEM DEV. . . . . SB FKT EG UNACH/CP
(DTE )
LINE: 1396 RNR: 3574 SI: DTE
003 ELEM DEV. . . . . SB FKT EG UNACH/CP
(FAX )
LINE: 1396 RNR: 3574 SI: FAX
DISPLAY-SDSU:,,DIUC,1,2,37;
PCM PATHS OF DIUC
-----------------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT)
P101.C60 1.LTU 2.037 DIUC64 A Q2185-X
PCM: 1 . . . . . . .
PCM: 2 . . . . . . .
DISPLAY-SDSU:,,STNO,PER2,3174;
STATION NUMBER ACCORDING TO PORT EQUIPMENT NUMBER
-------------------------------------------------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
P101.C60 1.LTU 1.025 SLMS A Q2117-X NPR
STNO INPUT CCT LINE STNO SI BUS TYPE
3173 003 128 FUNCT ONLY UNACH
MSN-CALL NUMBERS TO MAIN CALL NUMBER 3173
-------------------------------------------
MSNCALLNO LINE CP-STATUS
3174 334 READY
DISPLAY-SDSU:ALL,,TCSVR;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-LTUW---------SG 0 LTU 1 --------------------- READY
-LTUW---------SG 0 LTU 2 --------------------- READY
P101.C60 1.LTU 2.037 WAML A Q2205-X NL/WAIT
TC-SERVER . . . . . . . . . GENNR/UNACH
-LTUW---------SG 0 LTU 3 --------------------- READY
-LTUW---------SG 0 LTU 4 --------------------- READY
-LTUW---------SG 0 LTU 5 --------------------- NPR
-LTUW---------SG 0 LTU 6 --------------------- NPR
--------------SG 0 LTU 7 --------------------- NOGEN/NPR
--------------SG 0 LTU 8 --------------------- NOGEN/NPR
--------------SG 0 LTU 9 --------------------- NOGEN/NPR
--------------SG 0 LTU 10 --------------------- NOGEN/NPR
--------------SG 0 LTU 11 --------------------- NOGEN/NPR
--------------SG 0 LTU 12 --------------------- NOGEN/NPR
--------------SG 0 LTU 13 --------------------- NOGEN/NPR
--------------SG 0 LTU 14 --------------------- NOGEN/NPR
--------------SG 0 LTU 15 --------------------- NOGEN/NPR
--------------SG 0 LTU 16 --------------------- NOGEN/UNACH
-LTUW---------SG 8 LTU 55 --------------------- UNACH
DISPLAY-SDSU:ALL,,PEN,PER2,,1,55;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-LTUW---------SG 0 LTU 1 --------------------- READY
P101.C60 1.LTU 1.055 STMA A Q2160-X DEF/NL
REF. CLOCK . . . . . . . . . GENNR/UNACH
CCT LINE STNO SI BUS TYPE
000 1681 NOGEN
001 1682 NOGEN
002 1683 NOGEN
. . .
127 1808 NOGEN
DISPLAY-SDSU:UNACH&NPR,,PEN,PER2,,2,55;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
P101.C60 1.LTU 2.055 STMA A Q2160-X NPR
REF. CLOCK . . . . . . . . . UNACH
DISPLAY-SDSU:ALL,,PEN,PERI2,,2,73;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-LTUW---------SG 1 LTU 10 --------------------- NPR
** .LTG 1.LTU10.073 LTUCC Q2189-X100 NPR
CBMM 0 . . . . . . . . . UNACH
CBMM 1 . . . . . . . . . UNACH
CBMM 2 . . . . . . . . . UNACH
CBMM 3 . . . . . . . . . UNACH
DISPLAY-SDSU:ALL,,PEN,PERI2,,2,55;
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-LTUW---------SG 8 LTU 55 --------------------- UNACH
** .LTG 1.LTU55.019 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.025 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.031 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.037 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.043 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.049 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.055 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.061 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.067 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.073 NCUI Q2302-X UNACH
CCT LINE STNO SI BUS TYPE
000 699 NOGEN
. . .
012 711 NOGEN
** .LTG 1.LTU55.079 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.085 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.091 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.097 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.103 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.109 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.115 ........ .......... NOGEN/UNACH
** .LTG 1.LTU55.121 ........ .......... NOGEN/UNACH
P101.C60 1.LTU 2.079 DIU-S2 A Q2096-X200 READY
11111111111111111111111111
1111.22222.33333.444 55555555 66666 7 89999999999 00000000000000000000000000
Field 1: Physical cabinet designation
Cabinet row : P2
Cabinet number: 05
Field 2: Logical cabinet designation (CAB) consisting of
CAB TYPE: max. 3 characters (e.g. B, E, C, P)
CAB TYPE NUMBER: max. 2 characters (1)
Example: P1 = Periphery cabinet 1 (for LTG 1)
Field 3: Logical MOD designation
SHELF TYPE: max. 3 characters (e.g. GP, LTU)
SHELF TYPE NUMBER: max. 2 character (1-15)
Field 4: MOD slot
Field 5: Module abbreviation
Field 6: Module function
Output only for multifunctional modules
(e.g. SIUCO, MTS/CONF, SCC)
Field 7: HWY-bundle
Field 8: Actual BD (marked with '#')
Field 9: Module code number
Field 10: Status of the module
The data for the fields 'physical cabinet designation' 'CAB TYPE of logical cabinet desig
nation' and 'SHELF TYPE of logical MOD designation' are stored in the CAB TYPE file
or the FRAME TYPE file and are defined for the system in the system configuration table
of the ADS DB by means of AMO CONSY. If the DB is empty, output of central shelves
(CC, LTG or CSN) is not possible. For SWU periphery shelves the fields contain as
follows:
Temporary data for Field 1: **
Field 2: LTG
Field 3: LTU
The data for the fields 'module abbreviation' and 'module code number' are determined
using the HW ID from the loaded SUBSYSTEM ':PDS:APSU/BGDAT00'.
Note for HW ID:
If a module has the status NOGEN/NPR or NOGEN/UNACH, the fields 5 and 7 contain
'.', since the values for should-be and actual IDs are not present or not reliable.
If the status is NOGEN(/.../...?), the necessary data is determined using the actual ID
(marked with '#'); otherwise the should-be ID is used. For the central modules of CC and
the line trunk group (LTG) the data are always determined using the actual ID, since
should-be IDs cannot be entered by AMOs. The should-be ID (from basic initalization of
the DB) is only evaluated if the actual ID has the value 0 or H'777.
If the HW ID of a module cannot be converted, the ID is output in hexadecimal form in
the field module code number. The field module abbreviation is filled with '*'.
(This line is only output if PER2 or PER3 has been specified for LEVEL and it is a trunk
module.)
CCT LINE STNO SI BUS TYPE
012 260 4308 VOICE UNACH
111 22222 333333 44444 5555555555555 66666666666666666666666666Field 1: Trunk number
Field 2: physical line of trunk
Field 3: Directory number assigned to trunk (If the length of the station number is 0, the
bus type /= DB_BUS_NOT_DEFINED or the trunk status is NOGEN, a directory number
is not entered.)
Field 4: Service assigned to trunk
(No output, if there is no station number entered or at CTE)
Field 5: Bus type (from DB_M_BUS_TYPE_SET)
(no output at Bus type = DB_BUS_NOT_DEFINED)
possible output:
FUNCT CORNET, FUNCT ONLY, CORN. T ONLY PP NW,
PP CORNET, PP S0, PP S2, FCT WITH EAZField 6: Trunk status
STNO INPUT CCT LINE STNO SI BUS TYPE
3100 -> 001 43 3105 UNACH
111111 22 333 44444 555555 66666 7777777777777 88888888888888888888888888Field 1: specified directory number (single value or number from range)
Field 2: Advisory when directory no. (1) is not identical with directory no. (2) (i.e.: more
than one directory no. refers to this PEN, e.g. several subscribers use the same FAX
device.
Field 3: Trunk number
Field 4: physical line of trunk
Field 5: Directory number assigned to trunk
Field 6: Service assigned to trunk
Field 7: Bus type
Field 8: Trunk status
LINE INPUT CCT LINE STNO SI BUS TYPE
531 -> 000 334 CORN. T ONLY UNACH
11111 22 333 44444 555555 66666 7777777777777 88888888888888888888888888Field 1: specified line (single value or number from range)
Field 2: Advisory when input line is not identical with the physical line (i.e. at bus confi
gurations).
Field 3: Trunk number
Field 4: physical line of trunk
Field 5: Directory number assigned to trunk
Field 6: Service assigned to trunk
Field 7: Bus type
Field 8: Trunk status
(output after DCL module)
PBC 2 --------------------- READY
1 22222222222222222222222222Field 1: PBC number on the DCL module (1-4)
Field 2: Status of the PBC
(output after MTS module)
HWY 2 --------------------- READY
1 22222222222222222222222222Field 1: HWY input number on the MTS modules in CSN (0-63) and in GSN (0-31)
Field 2: Status of the HWY
(output after MD and DCL modules)
HDLC 2 --------------------- READY
1 22222222222222222222222222Field 1: Number of the HDLC path (to MD 1-9, to DCL 1-7, to QDCL 1-16)
Field 2: Status of the HDLC path
(output at TYPE=DIUC)
PCM: 1 . . . . . . . BIT_SLIP/REMOTE_CAS/LOST_FRAME
1 222222222222222222222222222222222222222222222222222222Field 1: Number of the PCM path (DIUC: 1, DIUC64: 1-2)
Field 2: Error states of the PCM path (derived from
DB_M_DEP_LOCK_SET)
(This line is only output if PER3 is specified for LEVEL and the module is a subscriber trunk
circuit.)
ELEM DEV. . . . . ANALOG TERM READY
111111111111111 2222222222222222 333333333333333333333333333Field 1: Line type: (from DB_M_LINE_STRUCT_INF_SET)
possible output:
NO CONN, ELEM DEV, SUBUNIT, NETWORK SUBUNIT,
MULTLINE 3, MULTLINE 16, MULTLINE 30, MULTLINE 256Field 2: Device type (from DB_M_CP_DEVICE_TYPE_SET)
possible output:
e.g. ANALOG TERM, DIGITE MAIN, ATT MAIN, ...Field 3: Device status
(This line is only output if PER3 is specified for LEVEL and the module is a subscriber trunk
module.)
000 ELEM_DEV. . . . . MAIN SECR READY/CP
111 222222222222222 3333333333333333 44444444444444444444444444Field 1: Device indicator of the device to MULTIPLE LINE
Field 2: Line type (from DB_M_LINE_STRUCT_INF_SET)
possible output: see Line 3, point 1
Field 3: Device type: (from DB_M_CP_DEVICE_TYPE_SET)
possible output: see Line 3, point 2
Field 4: Device status
Note for lines 3 and 4:
For NO_CONN or SIGNED OFF the STATUS field is not filled out. Lines with an empty
STATUS field are only output if the STATUS parameter value 'ALL' has been specified.
If the device type is displayed, output a additional line with the device name (if exists).
(OPTISET )
11111111Field 1: Device name (per CONV_REQUEST)
(This line is only output if line 4 is output and the concerning trunk has a bus configuration.)
LINE: 527 STNO: 3103 SI: DTE
11111 222222 33333Field 1: Fictitious or physical line of the device connected to bus
Field 2: Directory number of the device
Field 3: Service of the device
(This line is only output if PER3 is specified for LEVEL and the module is a subscriber trunk
module.)
001 . . . . . . . . . DIGITE SUB A UNACH
111 222222222222222 33333333333333333333333333Field 1: Number of the SUBUNIT
Field 2: Device type to the SUBUNIT (from DB_M_CP_DEVICE_TYPE_SET)
Field 3: Device status
(This line is only output if PER3 is specified for LEVEL and the digital or analog side of a
DTE modem is assigned to the PEN.)
PARTNER: 01.04.079.004 DI=000 SU=000
11 22 333 444 555 666Fields 1 - 6: Location of the remote side of the DTE modem
Field 1: LTG number
Field 2: LTU number
Field 3: Slot
Field 4: Trunk number
Field 5: Device indicator
Field 6: SUBUNIT number
Explanation of the Output Lines for LTG, LTU, HDLC, or HWY with TSL
------------------- LTG 1 --------------------- READY
or
------------------- LTU 1 --------------------- READY
or
------------------- HDLC 1 --------------------- DEF
or
-- LTU 7 -------- HWY 13 --------------------- READY
TSL 0 . . . . . . . . . . . DEF
(This line will be output, when a MSN call number, or a S0/S2 FPP station (also S0 bus) is
processed within the given range. In the first case, the CCT data line for the related main
station number will be output together with the MSN call numbers in the range.
In the second case, the CCT data line will be output and all related MSN call numbers.)
MSN-CALL NUMBERS TO MAIN CALL NUMBER 3556
1111
-------------------------------------------
MSNCALLNO LINE CP-STATUS
2595 68 READY
222222 33333 4444444444444444444444444
Field 1: station number of main station
Field 2: MSN call number
Field 3: number of the (fictitious) line
Field 4: CP status (from dynamic device memory)
(This line is only output, when PER2 or PER3 is specified for LEVEL and the concerning
line is disconnected.)
LINE_CONN: SIGNED OFF
111111111111111Field 1: Line type: (from DB_M_LINE_STRUCT_INF_SET)
possible output:
SIGNED OFF
| CCT | circuit/trunk number | ||||
| Type of Input: | single value, optional | ||||
| Possible Values: | numeric, 0-254 | ||||
| HWY | highway number | ||||
| Type of Input: | 1 to 2 single values, concatenated with &&, optional | ||||
| Possible Values: | numeric, 0-127 | ||||
| LEVEL | level of periphery output | ||||
| Type of Input: | single value, mandatory | ||||
| Possible Values: | PER1 | peripheral level 1 | (DISPLAY,TYPE=PEN-display status of periphery by port equipment no.) | ||
| PER2 | peripheral level 2 | ||||
| PER3 | peripheral level 3 | ||||
| LINE | line number | ||||
| Type of Input: | 1 to 2 single values, concatenated with &&, optional | ||||
| Possible Values: | numeric, 1-65535 | ||||
| LINK | type of status search (and, or) | ||||
| Type of Input: | single value, optional | ||||
| Possible Values: | AND | type of search function | |||
| OR | type of search function | ||||
| LTG | line/trunk group | ||||
| Type of Input: | single value, optional | ||||
| Possible Values: | numeric, 1 | ||||
| LTU | line/trunk unit | ||||
| Type of Input: | 1 to 2 single values, concatenated with &&, optional | ||||
| Possible Values: | numeric, 1-15, 17-99 | ||||
| PCM | pcm path | ||||
| Type of Input: | 1 to 2 single values, concatenated with &, optional | ||||
| Possible Values: | numeric, 1-2 | ||||
| PID | processor id for output | ||||
| Type of Input: | 0 to 2 single values, concatenated with &, optional | ||||
| Possible Values: | BP | base processor active (cc) | (DISPLAY,TYPE=UNIT-display status of central modules) | ||
| LTG | central boards of line trunk group | ||||
| SLOT | slot | ||||
| Type of Input: | single value, optional | ||||
| Possible Values: | numeric, 1-121 | ||||
| STATUS | module status of server to output | ||||
| Type of Input: | 0 to 4 single values, concatenated with &, optional | ||||
| Possible Values: | ALL | all states or services | |||
| ALLE | all states or services | ||||
| AMO | manually blocked by amo | ||||
| BUSY | busy, in use | ||||
| CP | seized by call processing | ||||
| CPH | cph bit of call processing | ||||
| DEF | blocked by dependibility because of a fault | ||||
| DEFIL | circuit alarm (defect in line) | ||||
| DEP | seized by dependability | ||||
| DEPLOCK | block caused by l2 error | ||||
| GENNR | generated but not ready | ||||
| HIRAMO | blocked due lock by amo | ||||
| LHB | local hardware block | ||||
| LICBLOCK | licblock | ||||
| LICMARK | licmark | ||||
| LMB | local maintenance block | ||||
| LOCK | hard block / out of service | ||||
| LSB | local software block | ||||
| NL | not loaded | ||||
| NOAL | no alarm | ||||
| NOGEN | not assigned (for swu) | ||||
| NPR | not present | ||||
| READY | in service | ||||
| RES | reserve | ||||
| RHB | remote hardware block | ||||
| RMB | remote maintenance block | ||||
| RSB | remote software block | ||||
| SIGNOFF | signed off | ||||
| SOFTLOCK | soft block / out of service pending | ||||
| SPEC | status display for specialist | ||||
| TRS | toll restriction | ||||
| UNACA | blocked due to interrelationships | ||||
| UNACH | hierarchical block | ||||
| WAIT | waiting for an event (e.g. end of loading) | ||||
| WBT | wrong board type | ||||
| STNO | station number | ||||
| Type of Input: | 1 to 2 single values, concatenated with &&, optional | ||||
| Possible Values: | numeric, 0-999999999999 | ||||
| SVC | communication service | ||||
| Type of Input: | 1 to 4 single values, concatenated with &, optional | ||||
| Possible Values: | ALL | all states or services | |||
| ALLE | all states or services | ||||
| DTE | data terminal equipment | ||||
| FAX | faxcimile communication service | ||||
| MSN | msn devices | ||||
| VCE | voice communication service | ||||
| TSL | time slot | ||||
| Type of Input: | 1 to 2 single values, concatenated with &&, optional | ||||
| Possible Values: | numeric, 0-31 | ||||
| TYPE | type of display | ||||
| Type of Input: | single value, mandatory | ||||
| Possible Values: | DIUC | display error status of pcm paths of a diuc | |||
| GSNHWY | display status of hwy gsn | ||||
| LINE | display status of periphery by line | ||||
| PEN | display status of periphery by port equipment no. | ||||
| STNO | display status of periphery by station number | ||||
| SVR | server state as seen from swu database | ||||
| TCSVR | display status of telecommuting server | ||||
| TSL | status display of timeslots | ||||
| UNIT | display status of central modules | ||||
| F01 | F01: ERROR ON RELOADING MODULE DATA
CONDITION CODE: @@@@@ | ||
| F02 | F02: NO DISPLAY OF TSL FOR HWY NUMBER @@@ | ||
| F03 | F03: PARAMETER VALUES ARE MISSING | ||
| F04 | F04: LTU @@.@@ IS NOT ASSIGNED | ||
| F05 | F05: NO MODULE IS ASSIGNED AT PEN @@.@@.@@@ | ||
| F06 | F06: MODULE AT PEN @@.@@.@@@ IS NOT A LINE INTERFACE MODULE | ||
| F07 | F07: CIRCUIT NO. @@@ FOR MODULE AT PEN @@.@@.@@@ TOO LARGE.
@@@ CIRCUITS ARE ASSIGNED FOR THIS MODULE | ||
| F08 | F08: THE LTG @@ IS NOT ASSIGNED | ||
| F09 | F09: MODULE AT SPECIFIED PEN IS NOT A WAML2 MODULE | ||
| F10 | F10: LTG @@ IS OUTSIDE THE PERMISSIBLE RANGE
VALID INPUT: 1 - @@ | ||
| F11 | F11: LTU @@ IS OUTSIDE THE PERMISSIBLE RANGE
VALID INPUT: 1 - @@ OR 17 - 99 | ||
| F13 | F13: SLOT @@.@@.@@@ NOT VALID | ||
| F14 | F14: LINE @@@@@ IS OUTSIDE THE PERMISSIBLE RANGE
VALID INPUT: 1 - @@@@@ | ||
| F15 | F15: FOR THE MTS MODULES TO OUTPUT ONLY THE HIGHWAYS @@@ - @@@
ARE PERMISSIBLE | ||
| F18 | F18: MODULE AT PEN @@.@@.@@@ IS NOT A DIUC MODULE | ||
| F19 | F19: THE DIUC MODULE AT SPECIFIED PEN HAS ONLY ONE PCM PATH | ||
| F20 | F20: PARTNER TASK IN LTG @@ DOES NOT RESPOND | ||
| F21 | F21: STNO BELONGS TO AN OLD FPP CONNECTION, WHICH IS NOT SUPPORTED
ANY MORE - SEE DISPLAY-SBCSU:STNO=@@@@@@@@@@@@. | ||
| F22 | F22: IMPOSSIBLE COMMUNICATION WITH MODULE @@@@@ DUE TO PROCESSOR FAILURE | ||
| F23 | F23: NO BOARD CONFIGURED ON SLOT @@@, INVALID STATE RECEIVED FROM
DEPENDABILITY (DC) | ||
| F24 | F24: MEMORY ALLOCATION FOR SUBSYSTEM '@@@@@@@@@@' NOT POSSIBLE | ||
| H01 | H01: SPECIFIED STATUS NOT FOUND | ||
| H02 | H02: SUPERFLUOUS PERIPHERAL ADDRESS PARAMETERS WERE IGNORED | ||
| H03 | H03: PARAMETER "LINK" ONLY VALID TOGETHER WITH INPUT FOR PARAMETER "STATUS" | ||
| H04 | H04: NO TELECOMMUTING SERVER FOUND | ||
| H05 | H05: NO DISPLAY OF TSL FOR HWY NUMBER @@@ | ||
| H06 | H06: VALUE "SPEC" OF PAR "STATUS" SUPPRESSES ALL OTHER VALUES OF "STATUS" | ||
| H09 | H09: FOR LTG @@ THERE IS NO ACTIVE SIDE | ||
| H10 | H10: FOR LTG @@ THERE IS NO STANDBY SIDE | ||
| H11 | H11: LTG @@ IS NOT ASSIGNED | ||
| H12 | H12: PARAMETER "AREA" EXTENDED WITH VALUE "PER2", DUE TO STATION NO. ENTERED | ||
| H13 | H13: NO PORT EQUIPMENT NUMBER FOUND FOR THE COMBINATION OF STNO/SVC | ||
| H14 | H14: PARAMETER "SVC" ONLY APPLIED FOR STATION NUMBER(S) ENTERED | ||
| H16 | H16: DATA FOR SHELF: @@@@@@@@ (UNIT @@@@@@@@) NOT FOUND IN FRAME TYPE FILE
OR ENTERED IN MORE VARIANTS. THE ACTUAL VARIANT CAN ONLY BE IDENTIFIED,
IF CONFIGURED BY AMO CONSY! | ||
| H17 | H17: NO PORT EQUIPMENT NUMBER FOUND FOR THE ENTERED LINES! | ||
| H18 | H18: AT BUSCONFIGURATIONS THE COMPLETE DISPLAY OF DATA IS ONLY POSSIBLE
WITH "PER3"! | ||
| H19 | H19: FOR THE MTS MODULES TO OUTPUT ONLY THE HIGHWAYS @@@ - @@@
ARE DISPLAYED | ||
| H20 | H20: PID @@@@@ NOT VALID IN SYSTEM TYPE | ||
| H21 | H21: STNO @@@@@@@@@@@@ IS NO MSN CALL NUMBER - USE SERVICE=ALL. | ||
| H22 | H22: AT TYPE=DIUC PARAMETER STATUS AND LINK WILL BE IGNORED | ||
| H23 | H23: STNO @@@@@@@@@@@@ SIGNED OFF, THE COMPLETE DISPLAY OF DATA IS ONLY
POSSIBLE WITH "PER3"! | ||
| H24 | H24: THE LINK STATUS COULD NOT BE READ. NO ANSWER FROM PP. | ||
| H25 | H25: THE LINK STATUS COULD NOT BE READ. NO PLAUSIBLE EVENT FROM PP. | ||
| H26 | H26: THE LINK STATUS COULD NOT BE READ. NO PLAUSIBLE MESSAGE DATA
RECEIVED FROM PP. | ||