| CHANGE-SLCB |
|
|
|
CTYPE=GAC, |
|
|
|
TYPE=DATA,[TRANSFER=<param>], POS=<number>, |
|
|
|
|
FORMAT=ASCII,CMDSTR=<string>; |
|
|
|
|
FORMAT=HEX,CMDARY=<hex>; |
|
|
|
TYPE=FILLEN,FILLEN=<number>; |
|
|
|
TYPE=INIT; |
|
|
CTYPE=CDAC, |
|
|
|
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, POS=<number>, |
|
|
|
|
FORMAT=ASCII,CMDSTR=<string>; |
|
|
|
|
FORMAT=HEX,CMDARY=<hex>; |
|
|
|
TYPE=FILLEN,FILLEN=<number>; |
|
|
|
TYPE=INIT,LTU=<number>, SLOT=<number>; |
|
|
CTYPE=CDSC, |
|
|
|
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, POS=<number>, |
|
|
|
|
FORMAT=ASCII,CMDSTR=<string>; |
|
|
|
|
FORMAT=HEX,CMDARY=<hex>; |
|
|
|
TYPE=FILLEN,FILLEN=<number>; |
|
|
|
TYPE=INIT,LTU=<number>, SLOT=<number>; |
|
|
CTYPE=BSAC, |
|
|
|
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, PORT=<number>, POS=<number>, |
|
|
|
|
FORMAT=ASCII,CMDSTR=<string>; |
|
|
|
|
FORMAT=HEX,CMDARY=<hex>; |
|
|
|
TYPE=FILLEN,FILLEN=<number>; |
|
|
|
TYPE=INIT,LTU=<number>, SLOT=<number>, [PORT=<number>]; |
|
|
CTYPE=BSSC, |
|
|
|
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, PORT=<number>, POS=<number>, |
|
|
|
|
FORMAT=ASCII,CMDSTR=<string>; |
|
|
|
|
FORMAT=HEX,CMDARY=<hex>; |
|
|
|
TYPE=FILLEN,FILLEN=<number>; |
|
|
|
TYPE=INIT,LTU=<number>, SLOT=<number>, [PORT=<number>]; |
|
|
CTYPE=PPAC, |
|
|
|
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, PORT=<number>, POS=<number>, |
|
|
|
|
FORMAT=ASCII,CMDSTR=<string>; |
|
|
|
|
FORMAT=HEX,CMDARY=<hex>; |
|
|
|
TYPE=FILLEN,FILLEN=<number>; |
|
|
|
TYPE=INIT,LTU=<number>, SLOT=<number>, [PORT=<number>]; |
|
|
CTYPE=PPSC, |
|
|
|
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, PORT=<number>, POS=<number>, |
|
|
|
|
FORMAT=ASCII,CMDSTR=<string>; |
|
|
|
|
FORMAT=HEX,CMDARY=<hex>; |
|
|
|
TYPE=FILLEN,FILLEN=<number>; |
|
|
|
TYPE=INIT,LTU=<number>, SLOT=<number>, [PORT=<number>]; |
|
|
CTYPE=CDDC, |
|
|
|
TYPE=FILLEN,FILLEN=<number>; |
|
|
|
TYPE=INIT,LTU=<number>, SLOT=<number>; |
|
|
CTYPE=BSDC, |
|
|
|
TYPE=FILLEN,FILLEN=<number>; |
|
|
|
TYPE=INIT,LTU=<number>, SLOT=<number>, PORT=<number>; |
|
|
CTYPE=PPDC, |
|
|
|
TYPE=FILLEN,FILLEN=<number>; |
|
|
|
TYPE=INIT,LTU=<number>, SLOT=<number>, PORT=<number>; |
|
CMDARY |
Command Array |
|
|
Type of Input: |
1 to 64 single values, concatenated with -, mandatory |
|
|
Possible Values: |
hexadecimal, up to 2 characters |
|
|
CMDSTR |
Command String |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
text, up to 64 characters |
|
|
CTYPE |
Container Type |
|
|
Type of Input: |
single value, mandatory |
(CHANGE / EXEC)
|
|
|
single value, optional |
(DISPLAY / REGENERATE)
|
|
|
Possible Values: |
BSAC |
BS (Base Station) Admin Container |
|
|
|
BSDC |
BS (Base Station) Dynamic Container |
|
(CHANGE / DISPLAY / REGENERATE)
|
|
|
BSSC |
BS (Base Station) Status Container |
|
(CHANGE / DISPLAY / REGENERATE)
|
|
|
CDAC |
CD (Common Data) Admin Container |
|
|
|
CDDC |
CD (Common Data) Dynamic Container |
|
(CHANGE / DISPLAY / REGENERATE)
|
|
|
CDSC |
CD (Common Data) Status Container |
|
(CHANGE / DISPLAY / REGENERATE)
|
|
|
GAC |
Global Admin Container |
|
|
|
PPAC |
PP (Portable Part) Admin Container |
|
|
|
PPDC |
PP (Portable Part) Dynamic Container |
|
(CHANGE / DISPLAY / REGENERATE)
|
|
|
PPSC |
PP (Portable Part) Status Container |
|
(CHANGE / DISPLAY / REGENERATE)
|
|
FILLEN |
Fill Length |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
numeric, 0-156 |
|
(CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=FILLEN-Fill Length)
|
|
|
numeric, 0-176 |
|
(CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=FILLEN-Fill Length)
|
|
|
numeric, 0-19 |
|
(CHANGE,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=FILLEN-Fill Length)
|
|
|
numeric, 0-2214 |
|
(CHANGE,CTYPE=CDAC-CD (Common Data) Admin Container,TYPE=FILLEN-Fill Length)
|
|
|
numeric, 0-22569 |
|
(CHANGE,CTYPE=GAC-Global Admin Container,TYPE=FILLEN-Fill Length)
|
|
|
numeric, 0-3638 |
|
(CHANGE,CTYPE=CDDC-CD (Common Data) Dynamic Container,TYPE=FILLEN-Fill Length)
|
|
|
numeric, 0-44 |
|
(CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=FILLEN-Fill Length)
|
|
|
numeric, 0-494 |
|
(CHANGE,CTYPE=CDSC-CD (Common Data) Status Container,TYPE=FILLEN-Fill Length)
|
|
|
numeric, 0-79 |
|
(CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=FILLEN-Fill Length)
|
|
|
numeric, 0-95 |
|
(CHANGE,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=FILLEN-Fill Length)
|
|
FORMAT |
Format of the entry |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
ASCII |
ascii |
|
|
|
HEX |
hex |
|
|
LENGTH |
Length of data requested |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 1-22570 |
|
|
LTU |
Line Trunk Unit |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
numeric, 1-15, 17-99 |
|
|
PORT |
Port of BS(0-23) and PP(88-215) |
|
|
Type of Input: |
1 to 15 single values, concatenated with & or &&, mandatory |
(CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data)
|
|
|
1 to 15 single values, concatenated with & or &&, optional |
(CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=INIT-Initialise Data / DISPLAY,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / DISPLAY,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data / EXEC,CTYPE=BSAC-BS (Base Station) Admin Container / EXEC,CTYPE=PPAC-PP (Portable Part) Admin Container / REGENERATE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / REGENERATE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data)
|
|
|
Possible Values: |
numeric, 0-23 |
|
(CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=INIT-Initialise Data / DISPLAY,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / EXEC,CTYPE=BSAC-BS (Base Station) Admin Container / REGENERATE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data)
|
|
|
numeric, 88-215 |
|
(CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=INIT-Initialise Data / DISPLAY,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data / EXEC,CTYPE=PPAC-PP (Portable Part) Admin Container / REGENERATE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data)
|
|
POS |
Position of data in container |
|
|
Type of Input: |
single value, mandatory |
(CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / CHANGE,CTYPE=CDAC-CD (Common Data) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=CDSC-CD (Common Data) Status Container,TYPE=DATA-data / CHANGE,CTYPE=GAC-Global Admin Container,TYPE=DATA-data / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data)
|
|
|
single value, optional |
(DISPLAY,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / DISPLAY,CTYPE=CDAC-CD (Common Data) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=CDDC-CD (Common Data) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=CDSC-CD (Common Data) Status Container,TYPE=DATA-data / DISPLAY,CTYPE=GAC-Global Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data / EXEC,CTYPE=CDAC-CD (Common Data) Admin Container / EXEC,CTYPE=GAC-Global Admin Container / REGENERATE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / REGENERATE,CTYPE=CDAC-CD (Common Data) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=CDSC-CD (Common Data) Status Container,TYPE=DATA-data / REGENERATE,CTYPE=GAC-Global Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data)
|
|
|
Possible Values: |
numeric, 0-65535 |
|
|
SLOT |
Slot |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
numeric, 1-121 |
|
|
TRANSFER |
Transfer of changed data to the board |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
|
|
|
YES |
yes |
|
|
TYPE |
Entry Type |
|
|
Type of Input: |
single value, mandatory |
(CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container / CHANGE,CTYPE=BSDC-BS (Base Station) Dynamic Container / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container / CHANGE,CTYPE=CDAC-CD (Common Data) Admin Container / CHANGE,CTYPE=CDDC-CD (Common Data) Dynamic Container / CHANGE,CTYPE=CDSC-CD (Common Data) Status Container / CHANGE,CTYPE=GAC-Global Admin Container / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container / CHANGE,CTYPE=PPDC-PP (Portable Part) Dynamic Container / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container)
|
|
|
single value, optional |
(DISPLAY,CTYPE=BSAC-BS (Base Station) Admin Container / DISPLAY,CTYPE=BSDC-BS (Base Station) Dynamic Container / DISPLAY,CTYPE=BSSC-BS (Base Station) Status Container / DISPLAY,CTYPE=CDAC-CD (Common Data) Admin Container / DISPLAY,CTYPE=CDDC-CD (Common Data) Dynamic Container / DISPLAY,CTYPE=CDSC-CD (Common Data) Status Container / DISPLAY,CTYPE=GAC-Global Admin Container / DISPLAY,CTYPE=PPAC-PP (Portable Part) Admin Container / DISPLAY,CTYPE=PPDC-PP (Portable Part) Dynamic Container / DISPLAY,CTYPE=PPSC-PP (Portable Part) Status Container / REGENERATE,CTYPE=BSAC-BS (Base Station) Admin Container / REGENERATE,CTYPE=BSSC-BS (Base Station) Status Container / REGENERATE,CTYPE=CDAC-CD (Common Data) Admin Container / REGENERATE,CTYPE=CDSC-CD (Common Data) Status Container / REGENERATE,CTYPE=GAC-Global Admin Container / REGENERATE,CTYPE=PPAC-PP (Portable Part) Admin Container / REGENERATE,CTYPE=PPSC-PP (Portable Part) Status Container)
|
|
|
Possible Values: |
DATA |
data |
|
(CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container / CHANGE,CTYPE=CDAC-CD (Common Data) Admin Container / CHANGE,CTYPE=CDSC-CD (Common Data) Status Container / CHANGE,CTYPE=GAC-Global Admin Container / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container / DISPLAY,CTYPE=BSAC-BS (Base Station) Admin Container / DISPLAY,CTYPE=BSDC-BS (Base Station) Dynamic Container / DISPLAY,CTYPE=BSSC-BS (Base Station) Status Container / DISPLAY,CTYPE=CDAC-CD (Common Data) Admin Container / DISPLAY,CTYPE=CDDC-CD (Common Data) Dynamic Container / DISPLAY,CTYPE=CDSC-CD (Common Data) Status Container / DISPLAY,CTYPE=GAC-Global Admin Container / DISPLAY,CTYPE=PPAC-PP (Portable Part) Admin Container / DISPLAY,CTYPE=PPDC-PP (Portable Part) Dynamic Container / DISPLAY,CTYPE=PPSC-PP (Portable Part) Status Container / REGENERATE,CTYPE=BSAC-BS (Base Station) Admin Container / REGENERATE,CTYPE=BSSC-BS (Base Station) Status Container / REGENERATE,CTYPE=CDAC-CD (Common Data) Admin Container / REGENERATE,CTYPE=CDSC-CD (Common Data) Status Container / REGENERATE,CTYPE=GAC-Global Admin Container / REGENERATE,CTYPE=PPAC-PP (Portable Part) Admin Container / REGENERATE,CTYPE=PPSC-PP (Portable Part) Status Container)
|
|
|
FILLEN |
Fill Length |
|
|
|
INIT |
Initialise Data |
|
(CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container / CHANGE,CTYPE=BSDC-BS (Base Station) Dynamic Container / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container / CHANGE,CTYPE=CDAC-CD (Common Data) Admin Container / CHANGE,CTYPE=CDDC-CD (Common Data) Dynamic Container / CHANGE,CTYPE=CDSC-CD (Common Data) Status Container / CHANGE,CTYPE=GAC-Global Admin Container / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container / CHANGE,CTYPE=PPDC-PP (Portable Part) Dynamic Container / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container)
|