SLCB - Configuration of for SLC24 Boards

AMO SLCB configures the board configuration data of SLC24 board for CMI V3.0 and further versions.
In addition to the means of plugging the board into LTU-Shelf and switching on by AMO-BSSU, board data will be dynamically loaded to SLC24 board during operation through PIT-PP, after data are written to DB.
It is possible to change board data without updating the data on SLC by specifying the parameter TRANSFER=NO. It is then responsibility of tools and user to aktualise CMI data on SLC. Some data must be sent to the SLC24 board in clusters, otherwise they will not be accepted by the board. Configuration tools must guarantee, that data clusters are sent to the board as complete. PIT response is timer controlled.
For unsuccessful loading of board data an error message will be issued and the AMO SLC24 will be aborted. Loading may be unsuccessful for the following reasons: EXECUTE-SLCB is also possible for part of Global and CD container data to have maximum flexibility. For PP and BS admin containers, with EXECUTE command whole containers will be sent.

Cross Reference to Other AMOs:

AMO ZANDE Setting CMI for V3.0
AMO DIMSU Dimensioning of features, switching unit
AMO BCSU Configuration of SLC24 board
AMO SBCSU Configuration of CMI Subscribers

Destination Processor: BP (Switching Unit)

Functions

CHANGE Change SLC24 board data password class 5
DISPLAY Display SLC24 board data password class 5
REGENERATE Regenerate SLC24 board data password class 5
EXEC Execute SLC24 board data password class 5

Procedure Overview

CHANGE-SLCB

CHANGE-SLCB
CTYPE=GAC,
TYPE=DATA,[TRANSFER=<param>], POS=<number>,
FORMAT=ASCII,CMDSTR=<string>;
FORMAT=HEX,CMDARY=<hex>;
TYPE=FILLEN,FILLEN=<number>;
TYPE=INIT;
CTYPE=CDAC,
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, POS=<number>,
FORMAT=ASCII,CMDSTR=<string>;
FORMAT=HEX,CMDARY=<hex>;
TYPE=FILLEN,FILLEN=<number>;
TYPE=INIT,LTU=<number>, SLOT=<number>;
CTYPE=CDSC,
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, POS=<number>,
FORMAT=ASCII,CMDSTR=<string>;
FORMAT=HEX,CMDARY=<hex>;
TYPE=FILLEN,FILLEN=<number>;
TYPE=INIT,LTU=<number>, SLOT=<number>;
CTYPE=BSAC,
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, PORT=<number>, POS=<number>,
FORMAT=ASCII,CMDSTR=<string>;
FORMAT=HEX,CMDARY=<hex>;
TYPE=FILLEN,FILLEN=<number>;
TYPE=INIT,LTU=<number>, SLOT=<number>, [PORT=<number>];
CTYPE=BSSC,
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, PORT=<number>, POS=<number>,
FORMAT=ASCII,CMDSTR=<string>;
FORMAT=HEX,CMDARY=<hex>;
TYPE=FILLEN,FILLEN=<number>;
TYPE=INIT,LTU=<number>, SLOT=<number>, [PORT=<number>];
CTYPE=PPAC,
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, PORT=<number>, POS=<number>,
FORMAT=ASCII,CMDSTR=<string>;
FORMAT=HEX,CMDARY=<hex>;
TYPE=FILLEN,FILLEN=<number>;
TYPE=INIT,LTU=<number>, SLOT=<number>, [PORT=<number>];
CTYPE=PPSC,
TYPE=DATA,[TRANSFER=<param>], LTU=<number>, SLOT=<number>, PORT=<number>, POS=<number>,
FORMAT=ASCII,CMDSTR=<string>;
FORMAT=HEX,CMDARY=<hex>;
TYPE=FILLEN,FILLEN=<number>;
TYPE=INIT,LTU=<number>, SLOT=<number>, [PORT=<number>];
CTYPE=CDDC,
TYPE=FILLEN,FILLEN=<number>;
TYPE=INIT,LTU=<number>, SLOT=<number>;
CTYPE=BSDC,
TYPE=FILLEN,FILLEN=<number>;
TYPE=INIT,LTU=<number>, SLOT=<number>, PORT=<number>;
CTYPE=PPDC,
TYPE=FILLEN,FILLEN=<number>;
TYPE=INIT,LTU=<number>, SLOT=<number>, PORT=<number>;

With command CHANGE, CMI configuration data in DB will be changed.
" If TRANSFER = YES is specified , entered value will be immediately sent to board via PIT - PP ( controlled by a timer).
If TRANSFER=NO is specified, data will be written only into DB.
Branch TYPE=DATA: Data can be entered in two ways but they will be written into DB only in hexadecimal format.
Branch TYPE=FILLEN: The fill length of the specified container will be written into DB.
Branch TYPE=INIT: Data of specified container will be initialised. This is actually delete action. Since LW expects always valid data from SWU, initialised data will not be sent.

DISPLAY-SLCB

DISPLAY-SLCB
[CTYPE=GAC],
[TYPE=DATA],[POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=CDAC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=BSAC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [PORT=<number>], [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=PPAC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [PORT=<number>], [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=CDSC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=CDDC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=BSSC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [PORT=<number>], [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=BSDC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [PORT=<number>], [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=PPSC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [PORT=<number>], [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=PPDC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [PORT=<number>], [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];

By means of function DISPLAY the configured board data are issued.
Since the contents of containers are not known to AMO, all data will be displayed as hexadecimal numbers.

REGENERATE-SLCB

REGENERATE-SLCB
[CTYPE=GAC],
[TYPE=DATA],[POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=CDAC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=CDSC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=BSAC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [PORT=<number>], [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=BSSC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [PORT=<number>], [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=PPAC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [PORT=<number>], [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=PPSC],
[TYPE=DATA],LTU=<number>, SLOT=<number>, [PORT=<number>], [POS=<number>], [LENGTH=<number>];
[TYPE=FILLEN];
[CTYPE=CDDC];
[CTYPE=BSDC];
[CTYPE=PPDC];

By means of action REGENERATE, CHANGE commands are regenerated for each board assigned by AMO SLCB.
Since the contents of containers are not known to AMO, all data will be regenerated as hexadecimal numbers.

EXEC-SLCB

EXEC-SLCB
CTYPE=GAC,[POS=<number>], [LENGTH=<number>];
CTYPE=CDAC,LTU=<number>, SLOT=<number>, [POS=<number>], [LENGTH=<number>];
CTYPE=BSAC,LTU=<number>, SLOT=<number>, [PORT=<number>];
CTYPE=PPAC,LTU=<number>, SLOT=<number>, [PORT=<number>];

Because of a requirement in LW, PPAC and BSAC must be sent to LW always as a complete package. Therefore for these containers the action EXECUTE is only possible for whole containers.

Parameter description

CMDARY Command Array
Type of Input: 1 to 64 single values, concatenated with -, mandatory
Possible Values: hexadecimal, up to 2 characters
CMDSTR Command String
Type of Input: single value, mandatory
Possible Values: text, up to 64 characters
CTYPE Container Type
Type of Input: single value, mandatory (CHANGE / EXEC)
single value, optional (DISPLAY / REGENERATE)
Possible Values: BSAC BS (Base Station) Admin Container
BSDC BS (Base Station) Dynamic Container (CHANGE / DISPLAY / REGENERATE)
BSSC BS (Base Station) Status Container (CHANGE / DISPLAY / REGENERATE)
CDAC CD (Common Data) Admin Container
CDDC CD (Common Data) Dynamic Container (CHANGE / DISPLAY / REGENERATE)
CDSC CD (Common Data) Status Container (CHANGE / DISPLAY / REGENERATE)
GAC Global Admin Container
PPAC PP (Portable Part) Admin Container
PPDC PP (Portable Part) Dynamic Container (CHANGE / DISPLAY / REGENERATE)
PPSC PP (Portable Part) Status Container (CHANGE / DISPLAY / REGENERATE)
FILLEN Fill Length
Type of Input: single value, mandatory
Possible Values: numeric, 0-156 (CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=FILLEN-Fill Length)
numeric, 0-176 (CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=FILLEN-Fill Length)
numeric, 0-19 (CHANGE,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=FILLEN-Fill Length)
numeric, 0-2214 (CHANGE,CTYPE=CDAC-CD (Common Data) Admin Container,TYPE=FILLEN-Fill Length)
numeric, 0-22569 (CHANGE,CTYPE=GAC-Global Admin Container,TYPE=FILLEN-Fill Length)
numeric, 0-3638 (CHANGE,CTYPE=CDDC-CD (Common Data) Dynamic Container,TYPE=FILLEN-Fill Length)
numeric, 0-44 (CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=FILLEN-Fill Length)
numeric, 0-494 (CHANGE,CTYPE=CDSC-CD (Common Data) Status Container,TYPE=FILLEN-Fill Length)
numeric, 0-79 (CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=FILLEN-Fill Length)
numeric, 0-95 (CHANGE,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=FILLEN-Fill Length)
FORMAT Format of the entry
Type of Input: single value, mandatory
Possible Values: ASCII ascii
HEX hex
LENGTH Length of data requested
Type of Input: single value, optional
Possible Values: numeric, 1-22570
LTU Line Trunk Unit
Type of Input: single value, mandatory
Possible Values: numeric, 1-15, 17-99
PORT Port of BS(0-23) and PP(88-215)
Type of Input: 1 to 15 single values, concatenated with & or &&, mandatory (CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data)
1 to 15 single values, concatenated with & or &&, optional (CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=INIT-Initialise Data / DISPLAY,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / DISPLAY,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data / EXEC,CTYPE=BSAC-BS (Base Station) Admin Container / EXEC,CTYPE=PPAC-PP (Portable Part) Admin Container / REGENERATE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / REGENERATE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data)
Possible Values: numeric, 0-23 (CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=INIT-Initialise Data / DISPLAY,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / EXEC,CTYPE=BSAC-BS (Base Station) Admin Container / REGENERATE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data)
numeric, 88-215 (CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=INIT-Initialise Data / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=INIT-Initialise Data / DISPLAY,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data / EXEC,CTYPE=PPAC-PP (Portable Part) Admin Container / REGENERATE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data)
POS Position of data in container
Type of Input: single value, mandatory (CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / CHANGE,CTYPE=CDAC-CD (Common Data) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=CDSC-CD (Common Data) Status Container,TYPE=DATA-data / CHANGE,CTYPE=GAC-Global Admin Container,TYPE=DATA-data / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data)
single value, optional (DISPLAY,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=BSDC-BS (Base Station) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / DISPLAY,CTYPE=CDAC-CD (Common Data) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=CDDC-CD (Common Data) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=CDSC-CD (Common Data) Status Container,TYPE=DATA-data / DISPLAY,CTYPE=GAC-Global Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / DISPLAY,CTYPE=PPDC-PP (Portable Part) Dynamic Container,TYPE=DATA-data / DISPLAY,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data / EXEC,CTYPE=CDAC-CD (Common Data) Admin Container / EXEC,CTYPE=GAC-Global Admin Container / REGENERATE,CTYPE=BSAC-BS (Base Station) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=BSSC-BS (Base Station) Status Container,TYPE=DATA-data / REGENERATE,CTYPE=CDAC-CD (Common Data) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=CDSC-CD (Common Data) Status Container,TYPE=DATA-data / REGENERATE,CTYPE=GAC-Global Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=PPAC-PP (Portable Part) Admin Container,TYPE=DATA-data / REGENERATE,CTYPE=PPSC-PP (Portable Part) Status Container,TYPE=DATA-data)
Possible Values: numeric, 0-65535
SLOT Slot
Type of Input: single value, mandatory
Possible Values: numeric, 1-121
TRANSFER Transfer of changed data to the board
Type of Input: single value, optional
Possible Values: NO no
YES yes
TYPE Entry Type
Type of Input: single value, mandatory (CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container / CHANGE,CTYPE=BSDC-BS (Base Station) Dynamic Container / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container / CHANGE,CTYPE=CDAC-CD (Common Data) Admin Container / CHANGE,CTYPE=CDDC-CD (Common Data) Dynamic Container / CHANGE,CTYPE=CDSC-CD (Common Data) Status Container / CHANGE,CTYPE=GAC-Global Admin Container / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container / CHANGE,CTYPE=PPDC-PP (Portable Part) Dynamic Container / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container)
single value, optional (DISPLAY,CTYPE=BSAC-BS (Base Station) Admin Container / DISPLAY,CTYPE=BSDC-BS (Base Station) Dynamic Container / DISPLAY,CTYPE=BSSC-BS (Base Station) Status Container / DISPLAY,CTYPE=CDAC-CD (Common Data) Admin Container / DISPLAY,CTYPE=CDDC-CD (Common Data) Dynamic Container / DISPLAY,CTYPE=CDSC-CD (Common Data) Status Container / DISPLAY,CTYPE=GAC-Global Admin Container / DISPLAY,CTYPE=PPAC-PP (Portable Part) Admin Container / DISPLAY,CTYPE=PPDC-PP (Portable Part) Dynamic Container / DISPLAY,CTYPE=PPSC-PP (Portable Part) Status Container / REGENERATE,CTYPE=BSAC-BS (Base Station) Admin Container / REGENERATE,CTYPE=BSSC-BS (Base Station) Status Container / REGENERATE,CTYPE=CDAC-CD (Common Data) Admin Container / REGENERATE,CTYPE=CDSC-CD (Common Data) Status Container / REGENERATE,CTYPE=GAC-Global Admin Container / REGENERATE,CTYPE=PPAC-PP (Portable Part) Admin Container / REGENERATE,CTYPE=PPSC-PP (Portable Part) Status Container)
Possible Values: DATA data (CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container / CHANGE,CTYPE=CDAC-CD (Common Data) Admin Container / CHANGE,CTYPE=CDSC-CD (Common Data) Status Container / CHANGE,CTYPE=GAC-Global Admin Container / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container / DISPLAY,CTYPE=BSAC-BS (Base Station) Admin Container / DISPLAY,CTYPE=BSDC-BS (Base Station) Dynamic Container / DISPLAY,CTYPE=BSSC-BS (Base Station) Status Container / DISPLAY,CTYPE=CDAC-CD (Common Data) Admin Container / DISPLAY,CTYPE=CDDC-CD (Common Data) Dynamic Container / DISPLAY,CTYPE=CDSC-CD (Common Data) Status Container / DISPLAY,CTYPE=GAC-Global Admin Container / DISPLAY,CTYPE=PPAC-PP (Portable Part) Admin Container / DISPLAY,CTYPE=PPDC-PP (Portable Part) Dynamic Container / DISPLAY,CTYPE=PPSC-PP (Portable Part) Status Container / REGENERATE,CTYPE=BSAC-BS (Base Station) Admin Container / REGENERATE,CTYPE=BSSC-BS (Base Station) Status Container / REGENERATE,CTYPE=CDAC-CD (Common Data) Admin Container / REGENERATE,CTYPE=CDSC-CD (Common Data) Status Container / REGENERATE,CTYPE=GAC-Global Admin Container / REGENERATE,CTYPE=PPAC-PP (Portable Part) Admin Container / REGENERATE,CTYPE=PPSC-PP (Portable Part) Status Container)
FILLEN Fill Length
INIT Initialise Data (CHANGE,CTYPE=BSAC-BS (Base Station) Admin Container / CHANGE,CTYPE=BSDC-BS (Base Station) Dynamic Container / CHANGE,CTYPE=BSSC-BS (Base Station) Status Container / CHANGE,CTYPE=CDAC-CD (Common Data) Admin Container / CHANGE,CTYPE=CDDC-CD (Common Data) Dynamic Container / CHANGE,CTYPE=CDSC-CD (Common Data) Status Container / CHANGE,CTYPE=GAC-Global Admin Container / CHANGE,CTYPE=PPAC-PP (Portable Part) Admin Container / CHANGE,CTYPE=PPDC-PP (Portable Part) Dynamic Container / CHANGE,CTYPE=PPSC-PP (Portable Part) Status Container)

Error Messages

F01
F01: AN SLC24 BOARD WITH ENTERED PEN (LTU =@@@, SLOT = @@@) HAS NOT BEEN 
     CONFIGURED (AMO BCSU). 
F02
F02: THE ENTERED PORT @@@ HAS NOT BEEN CONFIGURED (AMO SBCSU). 
F03
F03: POS (@@@@@) + LENGTH OF DATA ENTERED  (@@@@@) > FILLEN (@@@@@). 
F04
F04: THE DYNAMIC BOARD-ID FOR SLC24 (1-<ltu>-<slot>)IS NOT AVAILABLE.
F05
F05: DATA HAVE NOT BEEN LOADED TO SLC24 (1 - @@@ - @@@) 
     BECAUSE THE BOARD IS NOT IN STATE 'READY' (DISP-BCSU). 
F06
F06: TIME-OUT ERROR : NO ANSWER FROM PIT RECEIVED. 
F07
F07: NO PLAUSIBLE EVENT FROM PIT. 
F08
F08: DATA COULD NOT BE LOADED VIA PIT TO SLC24 BOARD (1 - @@@ - @@@) : (<loadresult>)  
F09
F09: THE ENTERED POS (@@@@@) IS GREATER THAN  FILLEN (@@@@@). 
F10
F10: LENGTH OF DATA ENTERED  (@@@@@) IS GREATER THAN  FILLEN (@@@@@). 
F11
F11: FILLEN OF DATA ENTERED  IS EQUAL TO 0 .

Advisory Messages

H01
H01: DO NOT FORGET TO TRANSFER CHANGED DATA TO BOARD EITHER WITH EXEC-SLCB 
     OR WITH RESTART-BSSU. 
H02
H02: <Feature data> Board data have been loaded
H03
H03: DATA HAVE NOT BEEN LOADED TO SLC24 (1 - @@@ - @@@) 
     BECAUSE THE BOARD IS NOT IN STATE 'READY' (DISP-BCSU).