ZANDE - System data - extended
This AMO is an extension of AMO-ZAND This AMO can be used to change, interrogate, and regenerate central system data. The data is divided into different data types to provide a better overview. | MLPP | Multi-Level Precedence and Preemption Service |
| ALLDATA | This includes all central system data from the database with the exception of the data that is changed by means of AMO FEASU (features). |
| OPTISET | Settings for OPTISET/OPTIPOINT devices |
| ATND | Settings for attendant console only |
| ACD | Settings for ACD-G |
| KEYSYS | Settings for Key System |
| DMC | Settings for DMC Connections |
| ACL | Settings for ACL related functions |
Destination Processor: BP (Switching Unit)
Functions
|
REGENERATE
|
Regenerate central system data SWU |
password class 2 |
|
DISPLAY
|
Interrogate central system data SWU |
password class 0 |
|
CHANGE
|
Change central system data in SWU |
password class 2 |
Procedure Overview
REGENERATE-ZANDE
Example
Regenerate system data. Input:
REG-ZANDE;
Output:
CHANGE-ZANDE:MLPP,NO,NO,NO,NO,NO,NO,NO,NO,NO,NO,NO,METHODE1;
CHANGE-ZANDE:ALLDATA,NO,NO,NO,NO,NO,NO,NO, AP EMERGENCY ,NO,NO,NO,NO,NO,NO,NO,NO,,NO,NO,NO,NO,NO;
CHANGE-ZANDE:ALLDATA2,NO,NO,NO,NO,NO,NO,NO,NO,NO;
CHANGE-ZANDE:OPTISET,NO,NO,NO,NO,NO,NO,NO,NO,NO,NO;
CHANGE-ZANDE:ATND,NO,NO;
CHANGE-ZANDE:ACD,NO,NO,NO,NO;
CHANGE-ZANDE:KEYSYS,NO,NO,NO,NO,NO;
CHANGE-ZANDE:DMC,NO,NO;
CHANGE-ZANDE:DLS,0.0.0.0,10444,NO;
CHANGE-ZANDE:SECURITY,YES,TRADITIO,128BIT,MIKEY1;
CHANGE-ZANDE:DNS,0.0.0.0,0.0.0.0;
CHANGE-ZANDE:OPTFEA,D,1000;
CHANGE-ZANDE:ACL,NO,NO,NO;
DISPLAY-ZANDE
Example
Interrogate MLPP central system data SWU Input:
DISPLAY-ZANDE:TYPE=MLPP;
Output:
MLPP SYSTEM DATA:
====================
DOMALLOC = YES, DOMCHECK = NO,
MCIQTAC = NO, USMUAUL = YES,
USMUXFER = YES, FWDPREC = YES,
CAMPPREC = NO, PNTTGLE = NO,
MCAUSE = N0, CWTPRECT = NO,
CONFDSCT = N0, GSCR = METHODE1;
CHANGE-ZANDE
| CHANGE-ZANDE |
|
|
|
TYPE=MLPP, {(min 1) DOMALLOC=<param>, DOMCHECK=<param>, MCIQTAC=<param>, USMUDIV=<param>, USMUXFER=<param>, FWDPREC=<param>, CAMPPREC=<param>, PNTTGLE=<param>, MCAUSE=<param>, CWTPRECT=<param>, CONFDSCT=<param>, GSCR=<param>, SEPHOTLN=<param>}; |
|
|
TYPE=ALLDATA, {(min 1) SCALLOG=<param>, H235SEC=<param>, GATEKPR=<param>, DECTPS=<param>, NONPIIW=<param>, DAJB=<param>, NOVNIDCO=<param>, APEDTXT=<string>, DRLEITNG=<param>, IMPRPKZ=<param>, SILMON=<param>, PSEPDIAL=<param>, CMIV30=<param>, DTMFPA=<param>, CFWDEPRT=<param>, DRPS=<param>, ALTCC=<key-num>, CMISLWDN=<param>, NVECOSPD=<param>, VECOSSPD=<param>, DNLPTHRL=<param>, STMIPRES=<param>, MRNGXFER=<param>, VNR=<param>, DISPMOD=<param>, CLIPTRNK=<param>, LEDSGVCE=<param>, SIPDIAL=<param>, NPLMSURV=<param>, SPS=<param>, VNRCN=<param>, BRANDID=<number>}; |
|
|
TYPE=ALLDATA2,[ANASPCH=<param>], [NOLANMON=<param>], [HIMED=<param>], [CFABLOOP=<param>], [CLIPNO=<param>], [DSNHOTLN=<param>], [LOGPART=<param>], [DTMF2833=<param>], [NOIPBLWL=<param>], [VNRDNO=<param>]; |
|
|
TYPE=OPTISET, {(min 1) EDITDIAL=<param>, SUPDRCPK=<param>, DISPPICK=<param>, NODDSLAB=<param>, CHSCALLD=<param>, DISPCFW=<param>, SNGLBTN=<param>, CHPARSIG=<param>, PINDISP=<param>, PROTDSS=<param>, SUPRDND=<param>}; |
|
|
TYPE=ATND, {(min 1) RECALLCO=<param>, RECCOMPN=<param>, NOINTTRS=<param>}; |
|
|
TYPE=ACD, {(min 1) LAUTHOFF=<param>, WHISANN=<param>, USERBUSY=<param>, RTOFFOLD=<param>, AICSACD=<param>, NOHOLDT=<param>, ORIGDNI=<param>, ACDALTRT=<param>, EXMNTONE=<param>, EXTSLTMN=<param>, ACDASST=<param>}; |
|
|
TYPE=KEYSYS, {(min 1) BRDGETON=<param>, LRNGCOFF=<param>, DSAALINC=<param>, NOLABEL=<param>}; |
|
|
TYPE=DMC,[EARLYDMC=<param>], [DMC2400=<param>]; |
|
|
TYPE=DLS, {(min 1) DLSIPADR=<number>, DLSPORT=<number>, DLSACPAS=<param>}; |
|
|
TYPE=SECURITY, {(min 1) SPESUPP=<param>, SECTDMSB=<param>, SECTDMTR=<param>, SECIPSB=<param>, SECIPTR=<param>, KEYLEN=<string>, MIKEYOPT=<param>, MHFAM=<param>, SECLVDSP=<param>, CONT=<param>}; |
|
|
TYPE=DNS,[DNSIPADR=<number>], [DNSIPAD2=<number>]; |
|
|
TYPE=OPTFEA,OPTFEA=<param>, FEANUM=<number>; |
|
|
TYPE=LOADBHV, |
|
|
|
PIT=HRBHV,LOAD=<param>; |
|
|
|
PIT=LWSRC,[PARTNO=<string>], [FCTID=<number>], LOADDEV=<param>; |
|
|
TYPE=ACL,[JOURBUSY=<param>], [DIVCRDIR=<param>], [CTSLMLON=<param>]; |
|
|
TYPE=ADDR,[ZIPCODE=<string>], [STRNAME=<string>], [STRNUM=<string>]; |
|
|
TYPE=OSMO,[SERVMAIL=<string>], [OSVTLS=<number>], [SBCSTLS=<number>], [QOSVIDEO=<number>], [DSCPTOS=<param>], [WMM=<param>], [SECOSV=<param>], [SECOSBC=<param>], [FEATLIST=<param>], [VCPRIO1=<param>], [VCPRIO2=<param>], [SBCFQDN1=<string>], [SBCADDR1=<number>], [PORT1=<number>], [SBCFQDN2=<string>], [SBCADDR2=<number>], [PORT2=<number>], [SBCFQDN3=<string>], [SBCADDR3=<number>], [PORT3=<number>], [SBCFQDN4=<string>], [SBCADDR4=<number>], [PORT4=<number>], [SBCFQDN5=<string>], [SBCADDR5=<number>], [PORT5=<number>]; |
|
|
TYPE=LICDATA, {(max 1) CLAADDR=<number>, CLAFQDN=<string>}, [CLAFQDNC=<string>], [CLAPORT=<number>], [LICENBL=<param>]; |
|
|
TYPE=ONLIC,[USEONLIC=<param>], [USESGLIC=<param>], [CLK=<string>], {(max 1) OCLAADDR=<number>, OCFQDN=<string>}, [OCFQDNC=<string>], [USEPROXY=<param>], {(max 1) PROXYIP=<number>, PFQDN=<string>}, [PFQDNC=<string>], [PROXYPRT=<number>], [PROXYUSR=<string>], [PROXYPAS=<string>]; |
The MLPP(multi level preselection and preemption) feature will allow users to assign priorities to a call. Calls with higher priority will preempt calls with lower priority when they are the reason that the called party is busy. Calls with higher priority will preempt calls with lower priority if they occupy resources which are needed by the call with the higher priority.
Changing the parameter USERBUSY in branch ACD :
When the parameter USERBUSY (how B-Channels are released) is changed, seizure attempts following such ACD calls with TDCSU SRCHMODE=ASC/DSC will be released with 'Requested circuit / channel not available', therefore either TDCSU SRCHMODE=CIR should be used or it should be ensured a second route (even using the same trunk group) is available in LDAT with AMO-RICHT parameter REROUT=YES.
Parameter description
|
ACDALTRT |
This Parameter activates the possible usage of an alternative route for ACD. |
|
|
Type of Input: |
single value, 8. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
ACDASST |
ACD behavior for SSXfered calls from Anate special station prevent call from following CFB after ACL SST when ACDSD:SYS AFTFWD=NO. |
|
|
Type of Input: |
single value, 11. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
AICSACD |
When AICS feature is activated then all calls are answered automatically. When AICSACD is on, then agents will be answered automatically only if they are logged on and available. |
|
|
Type of Input: |
single value, 5. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
ALTCC |
If an alternative country code number is configured, it can be assigned to trunks via COT=CACO. To delete the configured alternative country code, '*' has to be specified. Before deletion, all trunks should be checked if the COT is still used. |
|
|
Type of Input: |
single value, 17. parameter of a min-1-group |
|
|
Possible Values: |
0-9,*,#,A-D, up to 4 characters |
|
|
ANASPCH |
Speech instead of 3.1 kHz Audio for Analog phones |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
YES |
|
APEDTXT |
In case of AP Emergeny this text is displayed on all concerned Optiset/Optipoint devices DB-Initialization: AP Emergency |
|
|
Type of Input: |
single value, 8. parameter of a min-1-group |
|
|
Possible Values: |
text, 1 to 22 characters |
|
|
BRANDID |
Branding Identifier (DB-Initialization: 0) |
|
|
Type of Input: |
single value, 32. parameter of a min-1-group |
|
|
Possible Values: |
numeric, 0-255 |
|
|
BRDGETON |
If this parameter is set the bridge signalling tone generation for bridge features on key set devices will be deactivated. |
|
|
Type of Input: |
single value, 1. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
CAMPPREC |
Higher precedence incoming calls from the same service domain will preemt all existing calls (even if call waiting is activated at the called party). If this switch is not set all incoming calls will camp on to a busy called party regardless of the service domains and precedence levels. DB-Initialization: no |
|
|
Type of Input: |
single value, 7. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
CFABLOOP |
Activate A to ring instead of B with CFW Loop between A and B. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
CFWDEPRT |
The function of the source dependent routing will be modified with this change. If this parameter is set to YES, then the source group of the redirecting party will be used by the calling party to reach the CF-destination over survivability Path, instead of the source group of the calling party (Source Dependent Routing). DB-Initialization: no |
|
|
Type of Input: |
single value, 15. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
CHPARSIG |
Activate parallel signaling on Executive even if secretary has representative activated. |
|
|
Type of Input: |
single value, 8. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
CHSCALLD |
Delete Call Log entry with CHESE if same entry is deleted on Secr or Chef. |
|
|
Type of Input: |
single value, 5. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
CLAADDR |
CLA server IP address (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., 1. parameter of a max-1-group |
|
|
Possible Values: |
numeric, 0-255 |
|
|
CLAFQDN |
CLA server IP name (DB-Initialization: number 0.0.0.0) |
|
|
Type of Input: |
single value, 2. parameter of a max-1-group |
|
|
Possible Values: |
text (case sensitive), up to 128 characters |
|
|
CLAFQDNC |
CLA server name part 2 (character 129-255) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 127 characters |
|
|
CLAPORT |
CLA server port (DB-Initialization: 0) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-65535 |
|
|
CLIPNO |
CLIP/MWI behavior non standard to ETSI or Bellcore. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
CLIPTRNK |
CLIP Protocol Standart for trunks |
|
|
Type of Input: |
single value, 26. parameter of a min-1-group |
|
|
Possible Values: |
ACATDTMF |
DTMF WITH FIRST A AND SUBSEQ. TEL. CATEGORY 1 |
ACAT |
|
|
BCMDMF |
BELCORE with FSK and Multiple Data Message Format |
MDMF |
|
|
BCMDMF2 |
BELCORE with FSK2 and Multiple Data Message Format |
MDMF_2 |
|
|
BCSDMF |
BELCORE with FSK and Single Data Message Format |
SDMF |
|
|
BCSDMF2 |
BELCORE with FSK 2 and Single Data Message Format |
SDMF_2 |
|
|
ETSIDTMF |
ETSI with DTMF(Dual Tone Multi Frequency) |
DTMF |
|
|
ETSIFSK |
ETSI with FSK(Frequency Shift Key) |
FSK |
|
|
ETSIFSK2 |
ETSI with FSK(Frequency Shift Key)2 |
FSK_2 |
|
|
NONE |
Trunk CLIP standard neither DTMF nor FSK |
KEIN |
|
CLK |
Online CLK (Cloud License Key) (character 1-38) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text, up to 38 characters |
|
|
CMISLWDN |
Reduces message flood for SLC boards in case of a soft restart when many SLC boards are configured in a system to prevent deactivation of ports because of this message flood. |
|
|
Type of Input: |
single value, 18. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
CMIV30 |
If this parameter is set, CMI V3.0 configuration is possible whereas CMI V2.3 is not. DB-Initialization: no |
|
|
Type of Input: |
single value, 13. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
CONFDSCT |
In case of a precedence call a special conference disconnect tone is applied. If this switch is not set the old functionality is provided. DB-Initialization: no |
|
|
Type of Input: |
single value, 11. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
CONT |
Controls AMO flow. When CONT=NO an advisory message will be prompted and depending on user entry, the AMO will be cancelled or continued. When CONT=YES is entered the AMO will be started without prompting. |
|
|
Type of Input: |
single value, 10. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
CTSLMLON |
ACL-C ConnectTSL service allowed to use the ML classmark. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
CWTPRECT |
In case of a precedence call a special call waiting tone is applied. If this switch is not set the old functionality is provided. DB-Initialization: no |
|
|
Type of Input: |
single value, 10. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
DAJB |
If this parameter is set, the configuration for AJB is not possible and the old JB settings in branch DSP are used DB-Initialization: no |
|
|
Type of Input: |
single value, 6. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
DECTPS |
Via this parameter the DECT Positioning System (locating of DECT-mobile-phones) will be activated resp. deactivated. DB-Initialization: no |
|
|
Type of Input: |
single value, 4. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
DISPCFW |
Display CFW info at calling party anyway when no DivLeg3 info is received with ALERT. |
|
|
Type of Input: |
single value, 6. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DISPMOD |
Internal number display modificat. for virtual node traffic (DB-Initialization: UNKNOWN) |
|
|
Type of Input: |
single value, 25. parameter of a min-1-group |
|
|
Possible Values: |
ISDN |
The display is done in E.164 number format. |
DB_IN_MOD_ISDN |
|
|
PRIVATE |
The display is done in format Private Numbering Plan . " |
DB_IN_MOD_PRIVATE |
|
|
UNKNOWN |
Non VNR: For deactivated vitual numbering (feature VNR) the display of shortest possible subscriber numbers is done VNR: For activated vitual numbering (feature VNR) the display is done in format NODECD + subscriber number |
DB_IN_MOD_UNKNOWN |
|
DISPPICK |
If the parameter is set, the old display control (platform H300E IM / H300E UK) wil be activated for call pickup. If the parameter is not set, the HP4000 display control is activated. |
|
|
Type of Input: |
single value, 3. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DIVCRDIR |
ACL divert call request to call director. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DLSACPAS |
If the parameter is set, bootstrapping without PIN for DLS client is accepted. |
|
|
Type of Input: |
single value, 3. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DLSIPADR |
DLS server IP address (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., 1. parameter of a min-1-group |
|
|
Possible Values: |
numeric, 0-255 |
|
|
DLSPORT |
DLS server port (DB-Initialization: 10444) |
|
|
Type of Input: |
single value, 2. parameter of a min-1-group |
|
|
Possible Values: |
numeric, 0-65535 |
|
|
DMC2400 |
Used Resource Manager for bandwidth calculation across nodes. Use of a dummy SECNO with 2400 is required. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DNLPTHRL |
Activation of an additional DNIL path release in VECO. |
|
|
Type of Input: |
single value, 21. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DNSIPAD2 |
DNS server IP address 2 (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., optional |
|
|
Possible Values: |
numeric, 0-255 |
|
|
DNSIPADR |
DNS server IP address (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., optional |
|
|
Possible Values: |
numeric, 0-255 |
|
|
DOMALLOC |
An individual service domain is assigned to a non-MLPP call (and over-writes the function of COT:NMLT eventually). This switch is only valid with the FEASU switch MLPP. If this switch is not set a non-MLPP call will stay without a service domain. DB-Initialization: no |
|
|
Type of Input: |
single value, 1. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
DOMCHECK |
Preemption is allowed only within the same service domain. This switch is only valid with the FEASU switch MLPP. If this switch is not set preemption is allowed independent of the service domain. DB-Initialization: no |
|
|
Type of Input: |
single value, 2. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
DRLEITNG |
LED status display at DSS lines DB-Initialization: no |
|
|
Type of Input: |
single value, 9. parameter of a min-1-group |
|
|
Possible Values: |
NO |
LED status display at DSS lines |
FALSE |
|
|
YES |
no status display at DSS lines |
TRUE |
|
DRPS |
This is a disaster recovery switch. |
|
|
Type of Input: |
single value, 16. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DSAALINC |
If this parameter is set,also incoming calls on secondary lines of keysystems will be displayed. |
|
|
Type of Input: |
single value, 3. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DSCPTOS |
Enable DSCPTOS |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DSNHOTLN |
Activate the DSN hotline feature. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DTMF2833 |
Deactivate sending of DTMF via RFC2833 for HFA subscribers. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
DTMFPA |
If this bit is set the dialed numbers are sent as DTMF signs after CALL_PROCEEDING independent of the selected PROGRESS information. If this bit is NOT set DTMF signs are sent only if the PROGRESS 8 (inband_now_available) or 1 (not_end_to_end_ISDN) was received. DB-Initialization: no |
|
|
Type of Input: |
single value, 14. parameter of a min-1-group |
|
|
Possible Values: |
NO |
DTMF signs after CALL_PROCEEDING only if PROGRESS 1 or 8 |
FALSE |
|
|
YES |
Always DTMF signs after CALL_PROCEEDING |
TRUE |
|
EARLYDMC |
Early - DMC |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
EDITDIAL |
If this bit is set, it is possible to dial and edit thedialed digits but no dialing is started by the device. The collection of dialed digits is only possible while on-hooked device (also no dialing tone). DB-Initialization: no |
|
|
Type of Input: |
single value, 1. parameter of a min-1-group |
|
|
Possible Values: |
NO |
Edited dialing not possible |
FALSE |
|
|
YES |
Edited dialing possible |
TRUE |
|
EXMNTONE |
Extended tone monitoring |
|
|
Type of Input: |
single value, 9. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
EXTSLTMN |
Extended silent monitoring |
|
|
Type of Input: |
single value, 10. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
FCTID |
function identification for multi function boards |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-255 |
|
|
FEANUM |
The number of the optional feature |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
numeric, 0-2047 |
|
|
FEATLIST |
Supported OSMO Feature |
|
|
Type of Input: |
1 to 11 single values, concatenated with &, optional |
|
|
Possible Values: |
ALL |
Select all features |
DB_OSMO_FEAT_ALL |
|
|
CF |
Call Forward |
DB_OSMO_FEAT_CF |
|
|
CSC |
Consultation Call |
DB_OSMO_FEAT_CSC |
|
|
FC1 |
Call Forwarding Circuit 1 |
DB_OSMO_FEAT_FC1 |
|
|
GPC |
Group Call |
DB_OSMO_FEAT_GPC |
|
|
HF |
Handover From |
DB_OSMO_FEAT_HF |
|
|
NONE |
No feature selected |
DB_OSMO_FEAT_NONE |
|
|
SDND |
Snooze DND |
DB_OSMO_FEAT_SDND |
|
|
SEHO |
Seamless Handover |
DB_OSMO_FEAT_SEHO |
|
|
SIP |
SIP Over Data Connection |
DB_OSMO_FEAT_SIPDC |
|
|
SST |
Single Step Transfer |
DB_OSMO_FEAT_SST |
|
|
TOH |
Not supported |
DB_OSMO_FEAT_TOH |
|
|
XA |
Not supported |
DB_OSMO_FEAT_XA |
|
FLAGS |
Which flags should be displayed |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
ACTFLAGS |
Displaying only activated flags |
|
|
|
ALLFLAGS |
Displaying all flags |
|
|
FWDPREC |
Precedence calls will be forwarded. If this switch is not set precedence calls will not be forwarded. DB-Initialization: no |
|
|
Type of Input: |
single value, 6. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
GATEKPR |
gatekeeper configuration DB-Initialization: yes |
|
|
Type of Input: |
single value, 3. parameter of a min-1-group |
|
|
Possible Values: |
NO |
PBX without gatekeeper |
FALSE |
|
|
YES |
PBX with gatekeeper |
TRUE |
|
GSCR |
GSCR Trunk selection method. DB-Initialization: methode1 |
|
|
Type of Input: |
single value, 12. parameter of a min-1-group |
|
|
Possible Values: |
METHODE1 |
Trunk selection method 1 |
DB_MLPP_GSCR_SRH_MTH_2 |
|
|
METHODE2 |
Trunk selection method 2 |
DB_MLPP_GSCR_SRH_MTH_1 |
|
|
NOMETHOD |
No method |
DB_MLPP_GSCR_SRH_MTH_NULL |
|
|
Default Value: |
NOMETHOD |
|
H235SEC |
No longer supported. DB-Initialization: no |
|
|
Type of Input: |
single value, 2. parameter of a min-1-group |
|
|
Possible Values: |
NO |
Disable H.235 Security |
FALSE |
|
|
YES |
Enable H.235 Security |
TRUE |
|
HIMED |
Allows the usage of the digits *# and ## at the beginning of a dial string in LCR digit analysis for HIMED phones. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
IMPRPKZ |
" If this parameter is set , both levels of one name key can be chained for PKZ usage. DB-Initialization: no |
|
|
Type of Input: |
single value, 10. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
JOURBUSY |
ACL reports journal entry for busy chief. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
KEYLEN |
Security Key length (DB-Initialization: 128BIT) |
|
|
Type of Input: |
single value, 6. parameter of a min-1-group |
|
|
Possible Values: |
128BIT |
128 bit length |
DB_SEC_KEY_LEN_128_BIT |
|
LAUTHOFF |
ACD RTOFFs succeed despite of calling STN's LAUTH. DB-Initialization: no |
|
|
Type of Input: |
single value, 1. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
LEDSGVCE |
If this parameter is set the LED signalling (on anate device with LED) will be done only for voice messages but not on call FWDs |
|
|
Type of Input: |
single value, 27. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
LICENBL |
Enables or disables the Multiple Ring Transfer option. DB-Initialization: NO. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
LIST |
List Option |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
ALL |
Displaying all flash board types |
|
|
|
CONFIG |
Displaying only configured flash board types |
|
|
LOAD |
Loading of LW |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
LWLOAD |
LW to be loaded from HD |
LI_ZED_LW_LOAD |
|
|
NOLOAD |
Hard restart without loading/reset of periphery |
LI_ZED_NO_LOAD |
|
LOADDEV |
Device the loadware will be loaded from |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
FLASH |
reset of the forced load |
DB_FH_FLASH_LOADED |
|
|
HD |
forced load for the board |
DB_FH_FLASH_TO_BE_LOADED |
|
LOGPART |
Activate Logical Partioning : prevent conference between CO and private trunks. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
LRNGCOFF |
If the parameter is set, the line appearance specific feature ringer cut off is activated. |
|
|
Type of Input: |
single value, 2. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
MCAUSE |
MUF rules are applying.If this switch is not set the old functionality is provided. DB-Initialization: no |
|
|
Type of Input: |
single value, 9. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
MCIQTAC |
If this switch is set every MLPP level gets an own queue at the Attendant Console. If this switch is not set the old functionality is provided. DB-Initialization: no |
|
|
Type of Input: |
single value, 3. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
MHFAM |
Via this parameter the security settings for Mobile HFA subscriber are controlled. For activated feature SPE only the mode SECURE is allowed. |
|
|
Type of Input: |
single value, 8. parameter of a min-1-group |
|
|
Possible Values: |
SECURE |
secure |
TRUE |
|
|
STANDARD |
standard |
FALSE |
|
|
Default Value: |
STANDARD |
|
MIKEYOPT |
mikey option (DB-Initialization: MIKEY1) |
|
|
Type of Input: |
single value, 7. parameter of a min-1-group |
|
|
Possible Values: |
MIKEY1 |
mikey option 1 |
DB_SEC_MO_MIKEY_1 |
|
MRNGXFER |
Enables or disables the Multiple Ring Transfer option.(More than oneRing Transfer source key are activated on the same device). DB-Initialization: NO. |
|
|
Type of Input: |
single value, 23. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
NODDSLAB |
Hide the display of the key labels for DDS and DSS keys. The change of the currently displayed key labels comes into effect after plugging off/on the device or after a soft restart. |
|
|
Type of Input: |
single value, 4. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
NOHOLDT |
When this switch is on the silent monitoring party (supervisor) hears silence (instead of 'Please hold the line') if the monitored party (agent) is not on the line. |
|
|
Type of Input: |
single value, 6. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
NOINTTRS |
If NOINTTRS is set, then the incoming CO call to party A, which is transferred to internal party B, is not intercepted by Attendant. Party A has NODIV in SDAT. This parameter extends the function of NODIV from SDAT. DB-Initialization: no |
|
|
Type of Input: |
single value, 3. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
NOIPBLWL |
No IP board Loadware Load. When this parameter is set then loadware of gateway IP boards is not loaded by system software. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
NOLABEL |
Hide the text label of line-key and show only the number, name or text |
|
|
Type of Input: |
single value, 4. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
NOLANMON |
No LAN Monitoring |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
YES |
|
NONPIIW |
If this parameter is set, transit interworking of numbers from any numbering plan to any other numbering plan is switched off. There is neither interworking from ISDN to PNP, nor from PNP to ISDN, nor from Unknown Numbering Plan to any other nor from any numbering plan to Unknown Numbering Plan. (Note, that Unknown Numbering Plan is normally not used in U.S.) The parameter is used to fulfill the following request: In U.S., ISDN Numbering Plan numbers(E.164) for calling parties received from CO must be sent unchanged to private network lines. This is also requested, when the called party is sent as Private Numbering Plan (PNP) number. Attention: When using this parameter, a PUBNUM handling must be administered for all private extension numbers, that are sent to CO. Otherwise, the private extension number is sent unchanged to CO, that will cause the call be rejected. DB-Initialization: no |
|
|
Type of Input: |
single value, 5. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
NOVNIDCO |
Since HP4K V1.0 AMO KNMAT corrects the virtual node ID to avoid dependences from node to node in different regions. If NOVNIDCO=YES, this behaviour is disabled, what means the KNMAT modification works like HP4K V1.0 before. DB-Initialization: no |
|
|
Type of Input: |
single value, 7. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
NPLMSURV |
If NPLMSURV is set to YES then the traditional IPDA shelves will have an enhanced behavior similar to the Softgate behavior mentioned below. i.e An IPDA shelf in Sigalling survivability will connect to HHS and all other APs which are in a different source group over the alternative route. On the other hand connection to all APs which share the same Source group with the designated Softgate will be established over LAN if possible, and if not, then no connection will be possible. If this parameter is set to NO then we have the same functionality as in versions prior to V5. The old functionality was to use the alternate route to HHS only and try LAN connection to all other APs if possible. If a Softgate is in Signalling survivability, then connection to all other APs which are in a different source group than the designated Softgate, will be over the alternative route. On the other hand connection to all APs which share the same Source group with the designated Softgate will be established over LAN if possible, and if not, then no connection will be possible. Note: Parameter NPLMSURV has no effect on a Softgate which is in Signalling Survivability. SoftGate always follow the enhanced behavior. |
|
|
Type of Input: |
single value, 29. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
NVECOSPD |
VECO speed up with AMO DIAGS is not possible anymore. |
|
|
Type of Input: |
single value, 19. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
OCFQDN |
Online CLA server IP name part 1 (character 129-255) |
|
|
Type of Input: |
single value, 2. parameter of a max-1-group |
|
|
Possible Values: |
text (case sensitive), up to 128 characters |
|
|
OCFQDNC |
Online CLA server name part 2 (character 129-255) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 127 characters |
|
|
OCLAADDR |
Online CLA server IP address (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., 1. parameter of a max-1-group |
|
|
Possible Values: |
numeric, 0-255 |
|
|
OPTFEA |
Activate or deactivate the optional features |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
A |
activate |
TRUE |
|
|
D |
deactivate |
FALSE |
|
|
Default Value: |
D |
|
ORIGDNI |
If the parameter is YES on the calling party Display only the originaly dialed DNI number will be displayed and it will not be updated later after routing the call to an agent. |
|
|
Type of Input: |
single value, 7. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
OSVTLS |
OSV level of certificate security check |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-1 |
|
|
PARTNO |
part number of board to be set / reset |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text, up to 10 characters |
|
|
PFQDN |
Online Proxy server IP name part 1 (character 129-255) |
|
|
Type of Input: |
single value, 2. parameter of a max-1-group |
|
|
Possible Values: |
text (case sensitive), up to 128 characters |
|
|
PFQDNC |
Online Proxy server name part 2 (character 129-255) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 127 characters |
|
|
PINDISP |
Display PIN-subscriber as called party instead of PUG member to all other PUG members. |
|
|
Type of Input: |
single value, 9. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
PIT |
pit task |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
HRBHV |
Hard Restart Behaviour |
|
|
|
LWSRC |
flash memory to be loaded |
|
|
PNTTGLE |
A signalling tone is done when toggling back to a preemted held partner. If this switch is not set there will be no signalling tone. DB-Initialization: no |
|
|
Type of Input: |
single value, 8. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
PORT1 |
Server port (DB-Initialization: 0) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-65535 |
|
|
PORT2 |
Server port (DB-Initialization: 0) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-65535 |
|
|
PORT3 |
Server port (DB-Initialization: 0) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-65535 |
|
|
PORT4 |
Server port (DB-Initialization: 0) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-65535 |
|
|
PORT5 |
Server port (DB-Initialization: 0) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-65535 |
|
|
PROTDSS |
Prevent DSS-keys from being modified by user. |
|
|
Type of Input: |
single value, 10. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
PROXYIP |
Online Proxy server IP address (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., 1. parameter of a max-1-group |
|
|
Possible Values: |
numeric, 0-255 |
|
|
PROXYPAS |
Online Proxy Password (character 1-40) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 40 characters |
|
|
PROXYPRT |
Online Proxy server port (DB-Initialization: 0) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-65535 |
|
|
PROXYUSR |
Online Proxy User Name (character 1-40) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 40 characters |
|
|
PSEPDIAL |
If this parameter is set, It is possible to post dial a station number with impulse dial after dialing the PSE accesscode and the beeper number i.e. DTMF post dial will not work. DB-Initialization: no |
|
|
Type of Input: |
single value, 12. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
QOSVIDEO |
Value of QoS Video DSCP |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-254 |
|
|
RECALLCO |
If the parameter is set, a recall to the attendant after call transfer to the (CO) is possible. DB-Initialization: no |
|
|
Type of Input: |
single value, 1. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
RECCOMPN |
If the parameter is set, an access code specific company name will be displayed in case of a recall to the attendant. During default settings (parameter not set), the company name is derived from the ITR group of the called party. DB-Initialization: no |
|
|
Type of Input: |
single value, 2. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
RTOFFOLD |
If this parameter is set, the system uses ACD to route offsite to old system versions equal or smaller than EV3.0 |
|
|
Type of Input: |
single value, 4. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
SBCADDR1 |
Server IP address (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., optional |
|
|
Possible Values: |
numeric, 0-255 |
|
|
|
Default Value: |
0.0.0.0 |
|
SBCADDR2 |
Server IP address (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., optional |
|
|
Possible Values: |
numeric, 0-255 |
|
|
|
Default Value: |
0.0.0.0 |
|
SBCADDR3 |
Server IP address (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., optional |
|
|
Possible Values: |
numeric, 0-255 |
|
|
|
Default Value: |
0.0.0.0 |
|
SBCADDR4 |
Server IP address (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., optional |
|
|
Possible Values: |
numeric, 0-255 |
|
|
|
Default Value: |
0.0.0.0 |
|
SBCADDR5 |
Server IP address (DB-Initialization: 0.0.0.0) |
|
|
Type of Input: |
4 single values, concatenated with ., optional |
|
|
Possible Values: |
numeric, 0-255 |
|
|
|
Default Value: |
0.0.0.0 |
|
SBCFQDN1 |
Fully Qualified Domain Name (DB-Initialization: ) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 64 characters |
|
|
|
Default Value: |
|
|
SBCFQDN2 |
Fully Qualified Domain Name (DB-Initialization: ) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 64 characters |
|
|
|
Default Value: |
|
|
SBCFQDN3 |
Fully Qualified Domain Name (DB-Initialization: ) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 64 characters |
|
|
|
Default Value: |
|
|
SBCFQDN4 |
Fully Qualified Domain Name (DB-Initialization: ) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 64 characters |
|
|
|
Default Value: |
|
|
SBCFQDN5 |
Fully Qualified Domain Name (DB-Initialization: ) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 64 characters |
|
|
|
Default Value: |
|
|
SBCSTLS |
SBCS level of certificate security check |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 0-1 |
|
|
SCALLOG |
Source number in call log |
|
|
Type of Input: |
single value, 1. parameter of a min-1-group |
|
|
Possible Values: |
NO |
Current call log functionality. After transfer the attendantnumber (B party) is entered to the call log of C party " (DB-Initialization) |
FALSE |
|
|
YES |
After transfer the caller number (A party) is entered to the call log of C party |
TRUE |
|
SECIPSB |
Default security level for IP subscribers |
|
|
Type of Input: |
single value, 4. parameter of a min-1-group |
|
|
Possible Values: |
CIPHER |
cipher(HFA) |
DB_SPE_SEC_LEV_CIPHER |
|
|
SECURE |
secure |
DB_SPE_SEC_LEV_SECURE |
|
|
STANDARD |
standard(SIP) |
DB_SPE_SEC_LEV_STANDARD |
|
|
Default Value: |
SECURE |
|
SECIPTR |
Default security level for IP Trunks |
|
|
Type of Input: |
single value, 5. parameter of a min-1-group |
|
|
Possible Values: |
EXTSECUR |
extsecure |
DB_SPE_SEC_LEV_EXTSEC |
|
|
SECURE |
secure |
DB_SPE_SEC_LEV_SECURE |
|
|
STANDARD |
standard |
DB_SPE_SEC_LEV_STANDARD |
|
|
TRADITIO |
traditional |
DB_SPE_SEC_LEV_TRADITIONAL |
|
|
Default Value: |
SECURE |
|
SECLVDSP |
If this parameter is set, the call security level is displayed for each subscriber. |
|
|
Type of Input: |
single value, 9. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
SECOSBC |
Media Security Mode SBC |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
BESTEFRT |
Best effort |
DB_OSMO_SEC_BESTEFFORT |
|
|
NONE |
NONE |
DB_OSMO_SEC_NONE |
|
|
RTP |
RTP |
DB_OSMO_SEC_RTP |
|
|
SRTP |
SRTP |
DB_OSMO_SEC_SRTP |
|
|
Default Value: |
BESTEFRT |
|
SECOSV |
Media Security Mode OSV |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
BESTEFRT |
Best effort |
DB_OSMO_SEC_BESTEFFORT |
|
|
NONE |
NONE |
DB_OSMO_SEC_NONE |
|
|
RTP |
RTP |
DB_OSMO_SEC_RTP |
|
|
SRTP |
SRTP |
DB_OSMO_SEC_SRTP |
|
|
Default Value: |
BESTEFRT |
|
SECTDMSB |
Default security level for TDM subscribers |
|
|
Type of Input: |
single value, 2. parameter of a min-1-group |
|
|
Possible Values: |
SECURE |
secure |
DB_SPE_SEC_LEV_SECURE |
|
|
TRADITIO |
traditional |
DB_SPE_SEC_LEV_TRADITIONAL |
|
|
Default Value: |
TRADITIO |
|
SECTDMTR |
Default security level for TDM Trunks |
|
|
Type of Input: |
single value, 3. parameter of a min-1-group |
|
|
Possible Values: |
EXTSECUR |
extsecure |
DB_SPE_SEC_LEV_EXTSEC |
|
|
TRADITIO |
traditional |
DB_SPE_SEC_LEV_TRADITIONAL |
|
|
Default Value: |
TRADITIO |
|
SEPHOTLN |
Separate data and voice hotline |
|
|
Type of Input: |
single value, 13. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
SERVMAIL |
Customer service email. '******' delete the email address. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text (case sensitive), up to 64 characters |
|
|
|
Default Value: |
|
|
SILMON |
If this parameter is set, the silent monitoring is restricted to members of the ACD group of the monitor only. If this parameter is not set, there exist no restrictions to any ACD groups. DB-Initialization: no |
|
|
Type of Input: |
single value, 11. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
SIPDIAL |
This parameter activates the prepared dialing (block dialing) function according to the SIP phone user interface on HP8k. |
|
|
Type of Input: |
single value, 28. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
SNGLBTN |
Activate mail server (Xpressions) access via OpenStage envelope key as single button operation |
|
|
Type of Input: |
single value, 7. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
SPESUPP |
If the parameter is set, SPE is enabled. |
|
|
Type of Input: |
single value, 1. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
SPS |
This parameter activates the feature Signalling & Payload Seperation. |
|
|
Type of Input: |
single value, 30. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
STMIPRES |
If the parameter STMIPRES set,no broadcast is routed via HHS. Note: YES means NO STMI PRESENT! |
|
|
Type of Input: |
single value, 22. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
YES |
|
STRNAME |
Street Name of the Emergency Address |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text, 1 to 21 characters |
|
|
STRNUM |
Street Number of the Emergency Address |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text, 1 to 5 characters |
|
|
SUPDRCPK |
The menu item Directed Call Pickup " shall be removed from dialog menu if this parameter is set. DB-Initialization: no |
|
|
Type of Input: |
single value, 2. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
SUPRDND |
Remove menu item Do Not Disturb. |
|
|
Type of Input: |
single value, 11. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
TYPE |
Desired system option |
|
|
Type of Input: |
single value, mandatory |
(CHANGE / DISPLAY)
|
|
|
single value, optional |
(REGENERATE)
|
|
|
Possible Values: |
ACD |
Settings for ACD-G |
|
|
|
ACL |
Settings for ACL related functions |
|
|
|
ADDR |
Settings for ACL related functions |
|
(CHANGE)
|
|
|
ADDR |
address |
|
(DISPLAY / REGENERATE)
|
|
|
ALLDATA |
all system data |
|
|
|
ALLDATA2 |
all system data 2 |
|
|
|
ATND |
settings for attendant console |
|
|
|
DLS |
Settings for DLS |
|
|
|
DMC |
Settings for dmc connections |
|
|
|
DNS |
Settings for dns |
|
|
|
KEYSYS |
Settings for Key System |
|
|
|
LICDATA |
Settings for CLA data |
|
(CHANGE / DISPLAY)
|
|
|
LICDATA |
settings for CLA |
|
(REGENERATE)
|
|
|
LOADBHV |
Load behaviour |
|
(CHANGE / DISPLAY)
|
|
|
MLPP |
Multi-Level Precedence and Preemption Service |
|
|
|
ONLIC |
Online Licensing via Cloud settings |
|
|
|
OPTFEA |
Settings of optional features |
|
|
|
OPTISET |
settings for optiset devices |
|
|
|
OSMO |
OSMO |
|
(CHANGE)
|
|
|
OSMO |
OSMO feature |
|
(DISPLAY)
|
|
|
OSMO |
osmo |
|
(REGENERATE)
|
|
|
SECURITY |
Settings for security |
|
|
USEONLIC |
Enables or disables the 'Online Licensing' option. DB-Initialization: NO. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
USEPROXY |
Enables or disables the 'Use Proxy' option. DB-Initialization: NO. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
USERBUSY |
Release cause is USER-BUSY when ACD disconnects calls. |
|
|
Type of Input: |
single value, 3. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
USESGLIC |
Enables or disables the 'Online Licensing for SG and EntGW' option. DB-Initialization: NO. |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
USMUDIV |
Precedence calls will be diverted on MUF rules. If this switch is not set the old functionality is provided DB-Initialization: no |
|
|
Type of Input: |
single value, 4. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
USMUXFER |
Precedence levels will be updated on MUF rules. If this switch is not set the precedence levels will be updated on MLPP rules. DB-Initialization: no |
|
|
Type of Input: |
single value, 5. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
VCPRIO1 |
WIFI Video Codec Priority List |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
H264 |
H264 codec |
DB_OSMO_VCDC_H264 |
|
|
UNDEF |
Undefined |
DB_OSMO_VCDC_NONE |
|
|
VP8 |
VP8 codec |
DB_OSMO_VCDC_VP8 |
|
|
Default Value: |
Undef |
|
VCPRIO2 |
WIFI Video Codec Priority List |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
H264 |
H264 codec |
DB_OSMO_VCDC_H264 |
|
|
UNDEF |
Undefined |
DB_OSMO_VCDC_NONE |
|
|
VP8 |
VP8 codec |
DB_OSMO_VCDC_VP8 |
|
|
Default Value: |
Undef |
|
VECOSSPD |
VECO super speed up - designed for usage in the lab only, do never activate a customer switch !!! |
|
|
Type of Input: |
single value, 20. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
VNR |
Virtual numbering |
|
|
Type of Input: |
single value, 24. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
VNRCN |
VNR Closed Numbering (DB-Initialization: NO) |
|
|
Type of Input: |
single value, 31. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
VNRDNO |
VNR Display Node Number (DB-Initialization: NO) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
WHISANN |
If this parameter is set, the ACD-G feature Whisper Announcement will be activated. (DB-Initialization: NO) |
|
|
Type of Input: |
single value, 2. parameter of a min-1-group |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
WMM |
Enable Wireless Multi Media |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
NO |
no |
FALSE |
|
|
YES |
yes |
TRUE |
|
|
Default Value: |
NO |
|
ZIPCODE |
ZIP Code of the Emergency Address |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
text, 1 to 5 characters |
|
Error Messages
| F01 | F01: THERE IS AT LEAST ONE SLC BOARD CONFIGURED FOR @@@@@@@@.
PLEASE DELETE FIRST ALL CONFIGURED SLC BOARDS (DEL-BCSU). |
| F02 | F02: VNR MUST NOT BE ACTIVATED, IF SEVEN DIGITS NUMBERING IS ACTIVE
(PARAMETER SEVDIG IN AMO ZAND:TYPE=ALLDATA). |
| F03 | F03: VNR MUST NOT BE SWITCHED, WHEN VIRTUAL NODES ARE ASSIGNED (AMO KNDEF). |
| F04 | F04: SPESUPP CANNOT BE SWITCHED OFF IF SIGNENCR IS ACTIVATED.
PLEASE CHECK VIA DISPLAY-SIPCO:SECURITY; |
| F05 | F05: VNRCN CAN BE SET TO YES ONLY IF VNR = YES. |
| F06 | F06: CREATION OF SEGMENT FAILED WITH STATUS @@@@@@@@@@H |
| F07 | F07: LOADING SUBSYSTEM UBGDAT00 NOT POSSIBLE |
| F08 | F08: BOARD WITH PART NUMBER @@@@@@@@@@ IS NOT A FLASH BOARD |
| F09 | F09: FUNCTION IDENTIFICATION @@@ INVALID |
| F10 | F10: CHANGE OF THE SWITCH 'LOAD FLASH MEMORY' FOR NCUI NOT ALLOWED |
| F11 | F11: THE ENTERED BOARD IS NOT CONFIGURED IN THE SYSTEM. |
| F12 | F12: BOARD PART NUMBER @@@@@@@@@@ INVALID |
| F13 | F13: FCTID HAS TO BE ENTERED TOGETHER WITH PARTNO. |
| F14 | F14: FLASH HANDLING NOT YET FINISHED,
AT THE MOMENT THERE IS NO CHANGE/DISPLAY POSSIBLE.
PLEASE WAIT UNTIL FLASH HANDLING IS FINISHED.
(HISTA F4266: "CHANGE/DISPLAY OF LOADBHV IN AMO ZANDE NOW POSSIBLE")
THIS CAN TAKE SOME MINUTES |
| F15 | F15: VNR MUST NOT BE SWITCHED, WHEN DIALING CODES ARE CONFIGURED
(AMO WABE). |
| F16 | F16: IN STRNUM, ALL CHARACTERS EXCEPT THE LAST ONE HAVE TO BE NUMERIC. |
| F17 | F17: FOR STRNUM, MAX. 4 DIGITS + 1 OPTIONAL ALPHABETIC CHARACTER CAN
BE ENTERED. ONLY THE LAST CHARACTER CAN BE ALPHABETIC. |
| F18 | F18: ZIPCODE VALUE MUST BE NUMERIC. |
| F19 | F19: EITHER SBCFQDN/PORT OR IP ADDRES/PORT PAIR MAY BE SPECIFIED.
SBCFQDN AND SBCADDR ARE NOT ALLOWED AT THE SAME TIME. |
| F20 | F20: SPACES ARE NOT ALLOWED IN SBCFQDN OR SERVMAIL PARAMETER. |
| F21 | F21: ALL/NONE VALUE MUST BE ALONE IN FEATURE LIST. |
| F22 | F22: NO MEMORY FOR AP16, INCREASE BY ADD-DIMSU:AP= |
| F23 | F23: CLA DESTINATION MISSED |
| F24 | F24: SPESUPP CANNOT BE SWITCHED ON IF NON PAYL. ENCR. IS ACTIVATED IN LICENSE.
PLEASE CHECK VIA DISPLAY-CODEW; |
Advisory Messages
| USSU"> EXEC-USSU | EXEC-USSU:UPDATAP,@@@; |
| BSSU "> PLEASE RESET THE FOLLOWING CGW BOARDS BY MEANS OF RESTART-BSSU | PLEASE RESET THE FOLLOWING CGW BOARDS BY MEANS OF RESTART-BSSU : |
| USSU "> PLEASE RESET THE FOLLOWING NCUI BOARDS BY MEANS OF EXEC-USSU | PLEASE RESET THE FOLLOWING NCUI BOARDS BY MEANS OF EXEC-USSU : |
| BSSU"> RESTART-BSSU | RESTART-BSSU:PEN,1,@@@,@@@; |
| H02 | H02: A CHANGE OF THE GATEKEEPER SWITCH AFTER CONFIGURATION OF THE GATEKEEPER OR
HG 3550 GATEWAY(S) CAN RESULT IN MAJOR PROBLEMS IN OPERATION. DO YOU REALLY
WANT TO CONTINUE (YES / NO): |
| H03 | H03: THE ALTERNATIVE COUNTRY CODE HAS BEEN DELETED, CHECK IF COT=CACO
IS STILL USED FOR TRUNKS |
| H04 | H04: PARAMETER ALTCC CAN TAKE ONLY NUMERIC VALUES .
* SETS THE PARAMETER TO THE DB INITIALIZATION VALUE,
#,A-D ARE NOT VALID AND WILL BE IGNORED. |
| H05 | H05: CHANGING THE FLAG VNR HAS A BIG INFLUENCE OF COMPLETE SUBSCRIBER
CONFIGURATION. THIS CAN LEAD TO BIG TROUBLES LATER.
ARE YOU REALLY SURE ? |
| H06 | H06: THE CHANGE OF PARAMETER SPESUPP DOES NOT TAKE EFFECT ON WHOLE SYSTEM
UNLESS THE SYSTEM IS RESTARTED VIA COMMAND:
EXEC-REST:UNIT,BP,HARD;
(ON DUPLEX SYSTEMS BOTH PROCESSORS SIMULTANEOUSLY!!) |
| H07 | H07: THE CHANGE OF DLS OR DNS SETTINGS DOES NOT TAKE EFFECT ON CGW AND NCUI
BOARDS USING DEFAULT DLS SETTINGS UNLESS THE BOARDS ARE RESTARTED. |
| H08 | H08: SECIPSB=@@@@@@@@ CAN ONLY SERVE AUTOMATIC GENERATION OF @@@
SUBSCRIBERS: FOR ALL @@@ SUBSCRIBERS THE SECURITY CLASS MUST BE
ADJUSTED BY MEANS OF AMO-SDAT. |
| H09 | H09: THE CHANGE OF PARAMETER CLIPTRNK DOES NOT TAKE EFFECT ON TRUNK BOARDS
UNLESS THOSE BOARDS ARE RESTARTED BY MEANS OF AMO BSSU OR DSSU. |
| H10 | H10: SECURITY MODE FOR MOBILE HFA AUTOMATICALLY SET TO SECURE. |
| H11 | H11: ATTENTION ! SECURITY MODE FOR MOBILE HFA REMAINS SECURE. |
| H12 | H12: MHFAM=STANDARD IS NOT ALLOWED WHILE FEATURE SPE IS ACTIVATED. |
| H13 | H13: THIS CHANGE NEEDS A RESET OF ALL SUBSCRIBERS WITH ACTIVATED
SDAT ATTRIBUTE SECLVDSP.
IN CASE OF PARAMETER CONT IS YES, ALL CONCERNED SUBSCRIBERS WILL BE RESET
AUTOMATICALLY.
IN CASE OF PARAMETER CONT IS NO, EACH CONCERNED SUBSCRIBER HAS TO BE RESET
MANUALLY BY MEANS OF RES-DSSU:PEN,... |
| H14 | H14: By setting the parameter USERBUSY=YES it is strongly recommended to set
AMO-TDCSU parameter SRCHMODE=CIR for all outgoing trunks.
See also service handbook. |
| H15 | H15: PLEASE BE AWARE HFA PHONES USING TLS IN AN IPDA SHELF WILL NOT BE ABLE TO
LOG ON UNLESS SECURITY IS ALSO ACTIVATED FOR THE IPDA SHELF
(SIPCO:IPDAENCR). |
| H16 | H16: AMO ZANDE:SPS IS SET TO YES. IF A HUNT GROUP IS TO BE REACHED VIA THIS
CONFIGURATION AMO SA:LVAFTEXT MUST BE SET TO NO. |
| H17 | H17: THE OPTIONAL FEATURE IS ALREADY ACTIVATED. |
| H18 | H18: THE OPTIONAL FEATURE IS ALREADY DEACTIVATED. |
| H19 | H19: SAVE CHANGES OF ACTIVATION-FLAGS WITH 'EXEC-UPDAT:BP'. |
| H20 | H20: CHANGES ARE MADE FOR BOARD @@@@@@@@@@ with fctid @@ |
| H21 | H21: HPA as well as the corresponding classic board are displayed
in the list even if only one of them is configured. |
| H22 | H22: Changes are made for HPA Board @@@@@@@@@@ with fctid @@ and
corresponding classic Board @@@@@@@@@@ with fctid @@ |
| H23 | H23: ATTENTION! IF PARTNO AND FCTID ARE NOT ENTERED ALL CONFIGURED
FLASH BOARDS WILL BE AFFECTED! ARE YOU SURE? (YES/NO) : |
| H24 | H24: After hardrestart / reload, the values for LWSRC and HRBHV
will be set back to default FLASH / NOLOAD. |
| H25 | H25: NOT USED FLAGS ARE ONLY DISPLAYED IF ACTIVE. |
| H26 | H26: FQDN PART1 MISSED, CONTINUATION IGNORED. |
| H27 | H27: Feature H.235 Security is no longer supported |
| H28 | H28: CONFIGURATION WILL COME INTO EFFECT AFTER
SG/ENTGW RESTART OR SYSTEM RELOAD |
| H29 | H29: TOH & XA ARE NOT SUPPORTED. |
| H30 | H30: ONLIC CONFIGURATION HAVE BEEN LOADED TO SG/ENTGW @@. |