Feature:
Activate and deactivate call forwarding for subscribers by means of the attendant
console
or station.
Permit remote-control FWD
Block remote-control FWD
Function:
The attendant console (ATND) and subscribers can activate and deactivate variable
call
forwarding (FWD) for subscribers (FWD object). Any station number in the network is
available. Any call numbers that the subscriber has been able to set up as a FWD destination
can be designated as the call forwarding destination.
First you must set up the codes for activating (AFWDREM) and deactivating (DFWDREM)
the FWD
from the ATTND and from the station using the AMO WABE.
In order to permit remote-control FWD from the console and from the station in the
network,
you must set the CFOS COT parameter. This COT parameter is tested on the link between
the
ATTND and FWD object both for incoming and for outgoing digital tie trunks. The link
between
ATTND and station and FWD object must be set up with LCR.
The ATTND and the station must have FWDFAS rights, otherwise they cannot execute the
remote-control FWD. Rights are administered with AMO COS.
AMO Interrelationships:
COS <FWDFAS>, DPLN <DAR=AFWDREM, DAR=DFWDREM>
Device types:
Digital trunks
Protocol variants:
ECMAV2, PSS1V2