Collapse AllExpand All

17.57. NTON - Do not connect dial tone or announcement for incoming seizure of analog circuits Previous topic Parent topic Child topic Next topic

Feature:

Connect dial tone or announcement for incoming seizures

Function:

If the NTON parameter is set in the COT of an incoming seized analog circuit, no dial tone or announcement is connected to the calling node.
Only one of the COT parameters for the tone types may be set: Either PAR=NTON ... no tone or PAR=DTNI ... internal dial tone or PAR=DTNE ... external dial tone or PAR=VM ... Voice Mail or PAR=ANNC ... local announcement. If you do not follow this rule, then you cannot set up or modify a COT. Error message F04 or F05 is output.
F04: No parameter value specified for tone type NTON, DTNI, DTNE, VM, or ANNC
F05: Only one of the following tone types may be specified: NTON, DTNI, DTNE, VM, or ANNC

AMO interrelationships:

COT Classes of Trunks: DTNI, DTNE, VM, or ANNC
TACSU Configure Analog Trunks:
When configuring the analog circuits (AMO TACSU), if you do not assign NTON to
GW
:
Incoming trunk circuit, DDI, dialing group selection
MOSIG
:
Main station interface
DP
:
Dial pulse signaling
LNSEL
:
Two-way trunk circuit, outgoing DP and DTMF, with DDI, line selector
SFS
:
Incoming trunk circuit, monitoring frequency system; Flash to trunk
the system outputs the error message H14 "Conflict with default procedure for this device: trunk parameter NTON not entered (AMO COT)".
IMPORTANT:
The NTON parameter has no function for digital circuits, but you should activate it in the COT of these circuits. If you do not, the system cannot configure the assigned COT.

Device types:

Analog, digital trunk circuits, interface circuits, and tie trunks

Protocol versions:

All