Collapse AllExpand All

17.56. NQPI - Neighboring node does not support CorNet-NQ network-wide call pickup information Previous topic Parent topic Child topic Next topic

Feature:

Network-wide PU groups
Network-wide call pickup

Function:

In the case of ECMA or Cornet-NQ networks between a OpenScape 4000 and a Hicom 300 E V2.0 or a Hicom 300 E V1.0, the COT parameters NQPI and NQNP must be set on the tie trunk circuits of the OpenScape 4000, which lead to the Hicom 300 nodes of system version Hicom 300 E V2.0 (V3.6) or Hicom 300 E V1.0 (V3.5).
If the COT parameter NQPI or NQNP is not set, the connected number is missing in the call data record under CALL PICKUP. The error occurs because the FACility signal with a call pickup information element is not understood by the older Hicom 300 system versions Hicom 300 E V2 or Hicom 300 E V1.0.
NQPI = CorNet-NQ network-wide call pickup information for the network-wide PU groups feature is not supported between the calling and called subscribers (trunks that do not support NQ Operations Call Pick Info)
NQNP = CorNet-NQ network-wide call pickup between the calling and called subscribers is not supported (trunks that do not support NQ Operations Call Pick-up)

AMO Interrelationships:

AMO COT: <PAR=NQNP>

Device types:

Digital tie trunk circuits

Network protocols:

For example, ECMAV2 (CorNet-NQ Issue 2.1 Dec.96 Basic ETSI), PSS1V2 (CorNet-NQ Issue 2.1 Dec.96 Basic ISO/IEC)