Feature:
Network-wide PU groups
Network-wide call pickup
Function:
In the case of ECMA or Cornet-NQ networks between an OpenScape 4000 and a Hicom 300
E V2.0
or a Hicom 300 E V1.0, the COT parameters NQNP and NQPI must be set on the tie trunk
circuits of the OpenScape 4000, which lead to the Hicom 300 nodes of system version
Hicom
300 E V2.0 (V3.6) or Hicom 300 E V1.0 (V3.5).
If the COT Parameter NQNP or NQPI is not set, the connected number is missing in the
call
data record under CALL PICKUP. The error occurs because the FACility signal with a
call
pickup information element is not understood by the older Hicom 300 system versions
Hicom
300 E V2.0 or Hicom 300 E V1.0.
NQPI = CorNet-NQ network-wide call pickup information for the network-wide PU groups
feature is not supported between the calling and called subscribers (trunks that do
not
support NQ Operations Call Pick Info)
NQNP = CorNet-NQ network-wide call pickup between the calling and called subscribers
is not
supported (trunks that do not support NQ Operations Call Pick-up)
AMO Interrelationships:
AMO COT: <PAR=NQPI>
Device types:
Digital tie trunk circuits
Network protocols:
For example, ECMAV2 (CorNet-NQ Issue 2.1 Dec.96 Basic ETSI), PSS1V2 (CorNet-NQ Issue
2.1
Dec.96 Basic ISO/IEC)