Collapse AllExpand All

17.54. NPUN - Numbering Plan UNKNOWN on outgoing trunk calls Previous topic Parent topic Child topic Next topic

Feature:

This COT describes, that the next node can use numbers in Numbering plan UNKNOWN to reach this physical node. In general, this is a indication, that the switches at both ends of the trunk use numbering plan UNKNOWN for networking.

Function:

In more detail, is used to determine the NPI for sending redirection parties in case of set COT parameter AULN, RWSN, if the NPI can not be determined from the redirection party itself. E.g. A user B in switch 1 programms an internal CF by entering the extension of the redirection number only (normal case). If a user A in switch 2 calls B, networking must modify the redirection number in a way, that switch 2 can use this number to reach B. This COT defines, what NPI is used to sent the redirection party is from switch 1 to switch 2.

AMO-Interrelationships:

Only one of the 3 COT parameters NPPR,NPIS, NPUN must be set. If none of the 3 COT parameters is set, the system behaves as if NPUN was set. This COT is only relevant, if COT RWSL, AULN set. If incorrectly set: CF is not executed!

Device type:

Applicable to all digital trunks with outgoing calls

Protocol variants: