Collapse AllExpand All

17.34. MICC - MCID call clearing control required Previous topic Parent topic Child topic Next topic

Feature:

DSS 1 Terminals, MCID Malicious Call Identification (trace, identify malicious callers)

Function:

If a call is to be registered on a network-wide basis and if the connection line contains a DSS1 gateway, then the COT parameter MICC must be set on the DSS1 gateway (user side). This enables a network-wide call registration to be carried out after clearing.

AMO Interrelationships:

COS Classes of Service:
MCIDM: Class of service for activating the registration of an incoming call during the call and immediately after cleardown. This can be activated by means of the functional DSS1 protocol or by means of the TRACE digit analysis result.
TRACE: This class of service must be set together with the MCIDM class of service so that all incoming calls can be registered automatically. Additional manual registration is not possible.
MCIDA: Automatic registration of ringing malfunctions; the subscribers in question are calling subscribers that release before a call connection is established.

Device types:

Digital trunks

Protocol variants:

For example, EDSGER (EDSS1 protocol for Germany), EDSAUT (EDSS1 protocol for Austria), EDSSUI (EDSS1 protocol for Switzerland) EDSFRA (EDSS1 protocol for France)