Feature:
In order to ensure the full functionality of calls to the central attendant console
(CAS_EXTern) in a mixed network of OpenScape 4000 systems with older Hicom 300 systems.
Function:
Parameter set (do not send a CINT LEG 2 operation): In the case of the outgoing CAS
EXTernal call signaling, no service intercept operation with LEG2 information is sent;
instead the parameter is transferred in accordance with CorNet-N.
IMPORTANT:
Not to be set in the OpenScape 4000/HiPath 4000 homogenous
network.
The parameter works in an outgoing direction.
The value for the COT parameter must be set for outgoing digital tie trunk circuits
for
Hicom 300 systems.
AMO Interrelationships:
None
Device types:
For digital trunks only (centralized attendant console)
Protocol variants:
CorNetNQ