Collapse AllExpand All

17.60. PRI - Network-wide prioritized control of incoming calls at ATND Previous topic Parent topic Child topic Next topic

Feature:

Extended call queuing function at ATND

Function:

Network-wide prioritized control of incoming calls at the ATND in an homogeneous OpenScape4000/HiPath 4000 network connected via CorNet-NQ.
The function is activated with the COT parameter PRI function. This is to be set on the incoming seized CorNet-NQ trunks which are passed when the connection is established. This enables the data for prioritized control of incoming calls on the ATND to be transferred network-wide.
If a terminal causes an outgoing trunk seizure, then the priority number of the trunk of the outgoing trunk is transferred.
If the COT parameter PRI is not set, then the data for the extended call queuing function on the ATND is taken from the trunk's trunk memory when the trunk is seized.

AMO Interrelationships:

BUEND .... PRIONO =<priority class>;
FEASU .... Enable INCPRIO feature (increase priority after timeout)

Device types:

Digital interface circuits

Protocol variants:

ECMAV2, PSS1V2