Feature:
Extended call queuing function at ATND
Function:
Network-wide prioritized control of incoming calls at the ATND in an homogeneous
OpenScape4000/HiPath 4000 network connected via CorNet-NQ.
The function is activated with the COT parameter PRI function. This is to be set on
the
incoming seized CorNet-NQ trunks which are passed when the connection is established.
This
enables the data for prioritized control of incoming calls on the ATND to be transferred
network-wide.
If a terminal causes an outgoing trunk seizure, then the priority number of the trunk
of
the outgoing trunk is transferred.
If the COT parameter PRI is not set, then the data for the extended call queuing function
on the ATND is taken from the trunk's trunk memory when the trunk is seized.
AMO Interrelationships:
BUEND .... PRIONO =<priority class>;
FEASU .... Enable INCPRIO feature (increase priority after timeout)
Device types:
Digital interface circuits
Protocol variants:
ECMAV2, PSS1V2