Collapse AllExpand All

17.64. SANH - Synchronized Announcement of Non OpenScape 4000 Switch Previous topic Parent topic Child topic Next topic

Feature:

Configure COT-Parameter that indicates the authorization for use of synchronized announcement. This is, because these switches (non OpenScape 4000) do normally not send an authorization information for synchronized announcement as it is done in OpenScape 4000 network .

Function:

If COT parameter SANH is set for incoming trunk, also in case of Connection_Type /= AMT and no feature_indicator for internal use of synchronized announcement can be identified, the synchronized announcement can be used. Additionally, other COT parameters, ZAND switches. etc. has to be set correctly, as it is requested for this feature (see feature description, AMO -SYNCA).
If COT parameter SANH is not set for incoming trunk, the internal use of synchronized announcement is possible only in case of received feature-indicator for internal use of synchronized announcement. In case of incoming calls via Non OpenScape 4000 switches, no synchronized announcement can be used.
Hints:
This new COT parameter effects only incoming traffic for trunk.
Only for feature SYNCHRONIZED ANNOUNCEMENT!

AMO-Interrelationships:

COT parameters, ZAND switches

Device type:

his new COT parameter applies only for trunk devices (not for special trunks like PSM, PSE, ANSES, etc.)

Protocol variants:

Applies to all ISDN protocols.