STNOLEN
|
= 0
|
means no transparent mode; the recipient's
address must be assigned in the DPLN.
|
|
STNOLEN
|
= 1-20
|
means transparent mode will be used, and defines
the length of the code to be transmitted to the CC (B-blocks).
The
code length can either be fixed or variable, depending on the ENDRAUT
parameter (in AMO ZAND:TYPE=CCM):
ENDRAUT = NO: fixed length
ENDRAUT
= YES: variable length
STNOLEN defines the maximum length. Terminate
shorter codes with '#'. En-bloc dialing (number redial, destination
keys, key module, etc.) is not possible, if mixed mode with code digit
Section 156.4,
"Code Calling in MIXED MODE Operation with CODE DIGIT"