Collapse AllExpand All

11.4.5. Code Calling in TRANSPARENT MODE Operation Previous topic Parent topic Child topic Next topic

The transparent mode is possible for all types of operation, and is set by declaring the parameter STNOLEN in the TSCSU command.
STNOLEN
= 0
means no transparent mode; the recipient's address must be assigned in the DPLN.
STNOLEN
= 1-20
means transparent mode will be used, and defines the length of the code to be transmitted to the CC (B-blocks).
The code length can either be fixed or variable, depending on the ENDRAUT parameter (in AMO ZAND:TYPE=CCM):
ENDRAUT = NO: fixed length
ENDRAUT = YES: variable length
STNOLEN defines the maximum length. Terminate shorter codes with '#'. En-bloc dialing (number redial, destination keys, key module, etc.) is not possible, if mixed mode with code digit Section 156.4, "Code Calling in MIXED MODE Operation with CODE DIGIT" is used.