7.9.3.11. PTIME - Managing timers for peripherals Previous topic Parent topic Child topic Next topic

Changing the pulse duration or minimum pause duration between the metering pulses
CHA-PTIME:TYPE=SLMA1,TBLK=0,PULSED=<number>,PAUSED=<number>;
  • TBLK ... Timer block
  • PULSED ... Pulse duration
  • PAUSED ... Pause duration
The values for PULSED and PAUSED must be entered in 10 msec increments (i.e. for 80 msec the value is 8)
The timer block (TBLK) configured with the AMO PTIME must be assigned with the AMO SCSU in the CIRCIDX parameter (index for the timer block table for SLMAR):
  1. CHA-SCSU:STNO=<number>,CIRCIDX=0;
    
    If the original behavior for a station is to be restored, the value 16 must be specified for the CIRCIDX parameter when changing SCSU.
    A change in the pulse or pause duration does not take effect until the SLMAR board is loaded.