To prevent conflicts between 911 (emergency service) and 91-11-(KXX)-KXX-XXXX
(Flash data call), the switch must be programmed in such a manner that
after 911 is dialed and no other digits are received within 4 seconds
(or after a # is dialed), the call will be treated as an emergency service
call (911) and immediately processed. If additional digits are received
within the 4-second time period, the call will be treated as a non-emergency
call and handled appropriately.
ADD-WABE:CD=911,DAR=TIE,CHECK=N;
ADD-WABE:CD=*3,DAR=FLASH,CHECK=N;
ADD-RICHT:MODE=LRTENEW,LRTE=911,NAME="E911",
TGRP=229,DNNO=1-1-400,ROUTOPT=NO,REROUT=NO,
ROUTATT=NO,EMCYRTT=YES;
ADD-RICHT:MODE=LRTENEW,LRTE=912,NAME="MLPP",
TGRP=229,DNNO=1-1-400,ROUTOPT=NO,REROUT=NO,
ROUTATT=NO,EMCYRTT=NO;
/* E911 */
DELETE-LODR:TYPE=ODR,ODR=98;
ADD-LODR:ODR=98,CMD=OUTPULSE,DGTS=91;
/* "DNA E911 Target" */
ADD-LODR:ODR=98,CMD=SENDCOMP;
ADD-LODR:ODR=98,CMD=END;
ADD-LODR:ODR=98,INFO="E911";
ADD-LDAT:LROUTE=911,LVAL=1,TGRP=229,
ODR=98,LAUTH=1,CARRIER=1,ZONE=EMPTY,
LATTR=NONE;
ADD-LDPLN:LCRCONF=LCRPATT,DIPLNUM=0,
LDP=911-T,LROUTE=911,LAUTH=1;
/* MLPP*/
DELETE-LODR:TYPE=ODR,ODR=99;
ADD-LODR:ODR=99,CMD=OUTPULSE,DGTS=*3;
ADD-LODR:ODR=99,CMD=ECHO,FIELD=2;
ADD-LODR:ODR=99,CMD=SENDCOMP;
ADD-LODR:ODR=99,CMD=END;
ADD-LODR:ODR=99,INFO="MLPP";
ADD-LDAT:LROUTE=912,LVAL=1,TGRP=229,ODR=99,
LAUTH=1,CARRIER=1,ZONE=EMPTY,LATTR=RERTEINT;
ADD-LDPLN:LCRCONF=LCRPATT,DIPLNUM=0,LDP=911-X,
LROUTE=912,LAUTH=1;