There are many levels of CDR activation and many record-output settings
can be configured. The format of a CDR record can be very flexibly configured.
This section only describes specific aspects of the SMEO. These aspects
are the output of the Precedence Level and the Service Domain in a CDR
record. No further settings are necessary in order to enable the recording
of these two fields.
There are only special settings to configure a CDR format including
this fields and assign it to an output device. An example configuration
of a format containing the fields may look like this.
ADD-FTBL:4,B,CTRL,1,N,CR;
ADD-FTBL:4,B,CTRL,2,N,LF;
ADD-FTBL:4,B,FORM,3,N,"* ANL 80E116X *****
0 - 0 - 200 *** SMEO *******";
ADD-FTBL:4,B,CTRL,4,N,CR;ADD-FTBL:4,B,
CTRL,5,N,LF;
ADD-FTBL:4,B,FORM,6,N,"PRECLEV : #@ SVCDOMAIN:
#@@@@@@@@@@@@@@@@@@@ ";
ADD-FTBL:4,B,CTRL,7,N,CR;
ADD-FTBL:4,B,CTRL,8,N,LF;
ADD-FTBL:4,B,FORM,9,N,"CONNTYPE : #@@@@@@@@@
UNANS : #@@@@@@@@@ S";
ADD-FTBL:4,B,FORM,10,N,"UPLSERV : #@@@@@@@@@";
ADD-FTBL:4,B,CTRL,11,N,CR;
ADD-FTBL:4,B,CTRL,12,N,LF;
ADD-FTBL:4,B,FORM,13,N,"PAY-PTY : #@@@@@@@@@@@@@@@@@@@@@@
DEST-PTY ";
ADD-FTBL:4,B,FORM,14,N,": #@@@@@@@@@@@@@@@@@@@@@@ ";
ADD-FTBL:4,B,CTRL,15,N,CR;
ADD-FTBL:4,B,CTRL,16,N,LF;
ADD-FTBL:4,B,FORM,17,N,"CALLIPTY : #@@@@@@@@@@@@@@@@@@@@@@
CALLEPTY ";
ADD-FTBL:4,B,FORM,18,N,": #@@@@@@@@@@@@@@@@@@@@@@ ";
ADD-FTBL:4,B,CTRL,19,N,CR;
ADD-FTBL:4,B,CTRL,20,N,LF;
ADD-FTBL:4,B,FORM,21,N,"** RECORD-END
************************************";
ADD-FTBL:4,B,CTRL,22,N,CR;
ADD-FTBL:4,B,CTRL,23,N,LF;
ADD-FTBL:4,B,CTRL,24,Y,LF;
ADD-FTBL:4,B,FIELD,1,PRECLEVL,CHAR," ",R;
ADD-FTBL:4,B,FIELD,2,SVCDOM,CHAR," ",R;
ADD-FTBL:4,B,FIELD,3,CONNTYPE,CHAR," ",L;
ADD-FTBL:4,B,FIELD,4,UNANS,CHAR," ",L;
ADD-FTBL:4,B,FIELD,5,SUPLSERV,CHAR," ",L;
ADD-FTBL:4,B,FIELD,6,CHRGEE,CHAR," ",L;
ADD-FTBL:4,B,FIELD,7,DESTPTY,CHAR," ",L;
ADD-FTBL:4,B,FIELD,8,CALLIPTY,CHAR," ",L;
ADD-FTBL:4,B,FIELD,9,CALLEPTY,CHAR," ",L;
CHANGE-SELG:SELT,1,1,FORM04,NOFORM,TARGR00,"A22";
CHANGE-FEASU:A,MLPP;
ADD-WABE:*194,,,PRTY,NO;
ADD-WABE:*192,,,IMMED,NO;
ADD-WABE:*191,,,FLASH,NO;
ADD-WABE:*190,,,FLASHOV,NO;
CHANGE-ZAND:MLPP,NO,NO,NO,"SMEO",200-200-200-200-200,
NO;
CHANGE-SDAT:3260,DATA1,200,,,,,,,,,,,,,0-0-200-32-60,
,FLASHOV;
CHANGE-SDAT:3261,DATA1,200,,,,,,,,,,,,,0-0-200-32-61,
,FLASHOV;
CHANGE-SDAT:3262,DATA1,200,,,,,,,,,,,,,0-0-200-32-62,
,FLASHOV;
Using these settings, corresponding CDR records will look like this:
- MLPP call with precedence level flash (answered call)
* ANL 80E116X ***** 0 - 0 - 200 *** SMEO *******
PRECLEV : 1 SVCDOMAIN: 000-000-200-032-062
CONNTYPE : INTERN UNANS : DUV SUPLSERV :
NORMAL
PAY-PTY : 3262 DEST-PTY : 3260
CALLIPTY : 3262 CALLEPTY : 3260
** RECORD-END ************************************
- MLPP call with precedence level priority (answered call)
* ANL 80E116X ***** 0 - 0 - 200 *** SMEO *******
PRECLEV : 3 SVCDOMAIN: 000-000-200-032-060
CONNTYPE : INTERN UNANS : DUV SUPLSERV :
NORMAL
PAY-PTY : 3260 DEST-PTY : 3262
CALLIPTY : 3260 CALLEPTY : 3262
** RECORD-END ************************************
- Call with precedence level routine (unanswered call)
* ANL 80E116X ***** 0 - 0 - 200 *** SMEO *******
PRECLEV : 4 SVCDOMAIN: 000-000-200-032-061
CONNTYPE : INTERN UNANS : NICHT DUV SUPLSERV :
RING_BACK
PAY-PTY : 3261 DEST-PTY : 3260
CALLIPTY : 3261 CALLEPTY : 3260
** RECORD-END ************************************