Collapse AllExpand All

14.4.8. CDR Fields (SMEO) Previous topic Parent topic Child topic Next topic

There are many levels of CDR activation and many record-output settings can be configured. The format of a CDR record can be very flexibly configured.
This section only describes specific aspects of the SMEO. These aspects are the output of the Precedence Level and the Service Domain in a CDR record. No further settings are necessary in order to enable the recording of these two fields.
There are only special settings to configure a CDR format including this fields and assign it to an output device. An example configuration of a format containing the fields may look like this.
ADD-FTBL:4,B,CTRL,1,N,CR;

ADD-FTBL:4,B,CTRL,2,N,LF;

ADD-FTBL:4,B,FORM,3,N,"* ANL 80E116X *****  
0 - 0 - 200  *** SMEO *******";

ADD-FTBL:4,B,CTRL,4,N,CR;ADD-FTBL:4,B,
CTRL,5,N,LF;

ADD-FTBL:4,B,FORM,6,N,"PRECLEV :  #@  SVCDOMAIN: 
#@@@@@@@@@@@@@@@@@@@   ";

ADD-FTBL:4,B,CTRL,7,N,CR;

ADD-FTBL:4,B,CTRL,8,N,LF;

ADD-FTBL:4,B,FORM,9,N,"CONNTYPE : #@@@@@@@@@      
UNANS  : #@@@@@@@@@   S";

ADD-FTBL:4,B,FORM,10,N,"UPLSERV : #@@@@@@@@@";

ADD-FTBL:4,B,CTRL,11,N,CR;

ADD-FTBL:4,B,CTRL,12,N,LF;

ADD-FTBL:4,B,FORM,13,N,"PAY-PTY  : #@@@@@@@@@@@@@@@@@@@@@@       
DEST-PTY ";

ADD-FTBL:4,B,FORM,14,N,": #@@@@@@@@@@@@@@@@@@@@@@     ";

ADD-FTBL:4,B,CTRL,15,N,CR;

ADD-FTBL:4,B,CTRL,16,N,LF;

ADD-FTBL:4,B,FORM,17,N,"CALLIPTY : #@@@@@@@@@@@@@@@@@@@@@@       
CALLEPTY ";

ADD-FTBL:4,B,FORM,18,N,": #@@@@@@@@@@@@@@@@@@@@@@     ";

ADD-FTBL:4,B,CTRL,19,N,CR;

ADD-FTBL:4,B,CTRL,20,N,LF;

ADD-FTBL:4,B,FORM,21,N,"** RECORD-END 
************************************";

ADD-FTBL:4,B,CTRL,22,N,CR;

ADD-FTBL:4,B,CTRL,23,N,LF;

ADD-FTBL:4,B,CTRL,24,Y,LF;

ADD-FTBL:4,B,FIELD,1,PRECLEVL,CHAR," ",R;

ADD-FTBL:4,B,FIELD,2,SVCDOM,CHAR," ",R;

ADD-FTBL:4,B,FIELD,3,CONNTYPE,CHAR," ",L;

ADD-FTBL:4,B,FIELD,4,UNANS,CHAR," ",L;

ADD-FTBL:4,B,FIELD,5,SUPLSERV,CHAR," ",L;

ADD-FTBL:4,B,FIELD,6,CHRGEE,CHAR," ",L;

ADD-FTBL:4,B,FIELD,7,DESTPTY,CHAR," ",L;

ADD-FTBL:4,B,FIELD,8,CALLIPTY,CHAR," ",L;

ADD-FTBL:4,B,FIELD,9,CALLEPTY,CHAR," ",L;
 CHANGE-SELG:SELT,1,1,FORM04,NOFORM,TARGR00,"A22";
 CHANGE-FEASU:A,MLPP;
 ADD-WABE:*194,,,PRTY,NO;

ADD-WABE:*192,,,IMMED,NO;

ADD-WABE:*191,,,FLASH,NO;

ADD-WABE:*190,,,FLASHOV,NO;
 
CHANGE-ZAND:MLPP,NO,NO,NO,"SMEO",200-200-200-200-200,
NO;
 
CHANGE-SDAT:3260,DATA1,200,,,,,,,,,,,,,0-0-200-32-60,
,FLASHOV;

CHANGE-SDAT:3261,DATA1,200,,,,,,,,,,,,,0-0-200-32-61,
,FLASHOV;

CHANGE-SDAT:3262,DATA1,200,,,,,,,,,,,,,0-0-200-32-62,
,FLASHOV;


Using these settings, corresponding CDR records will look like this:
  • MLPP call with precedence level flash (answered call)
    * ANL 80E116X *****  0 - 0 - 200  *** SMEO *******
     PRECLEV :   1  SVCDOMAIN:  000-000-200-032-062   
     CONNTYPE : INTERN          UNANS  : DUV          SUPLSERV : 
    NORMAL    
     PAY-PTY  : 3262                          DEST-PTY : 3260                        
     CALLIPTY : 3262                          CALLEPTY : 3260                        
     ** RECORD-END ************************************
    
  • MLPP call with precedence level priority (answered call)
    * ANL 80E116X *****  0 - 0 - 200  *** SMEO *******
     PRECLEV :   3  SVCDOMAIN:  000-000-200-032-060   
     CONNTYPE : INTERN          UNANS  : DUV          SUPLSERV : 
    NORMAL    
     PAY-PTY  : 3260                          DEST-PTY : 3262                        
     CALLIPTY : 3260                          CALLEPTY : 3262                        
     ** RECORD-END ************************************
    
  • Call with precedence level routine (unanswered call)
    * ANL 80E116X *****  0 - 0 - 200  *** SMEO *******
     PRECLEV :   4  SVCDOMAIN:  000-000-200-032-061   
     CONNTYPE : INTERN          UNANS  : NICHT DUV    SUPLSERV : 
    RING_BACK 
     PAY-PTY  : 3261                          DEST-PTY : 3260                        
     CALLIPTY : 3261                          CALLEPTY : 3260                        
     ** RECORD-END ************************************