The module is intended for use in the USA only. Configuration for Ground
Start or Loop Start is based on the type of CO connected and also on
whether the connected CO is operated with pulse dialing or DTMF dialing.
If a call process tone from the CO is to be waited for in the case
of an outgoing seizure, the COP parameter SDL must be set (a dial tone
receiver is then switched in the outgoing circuit and the tone received
from the CO is analyzed).
If the CO does not transmit a seizure acknowledgement in the case
of an outgoing connection (if provided for in the protocol), the CYCSET
(DTIM1:CO) Timer in the OpenScape 4000 runs out first, followed by the
STADIAL2 (DTIM2:LNGEN) Timer. Once the STADIAL2 Timer has expired, OUTGOING
SEIZURE is attempted again. This sequence of timers and attempts at outgoing
seizure is repeated infinitely until positive acknowledgement is received
from the CO.
DTMF post-dialing must be configured in AMO RICHT.
In the case of an outgoing seizure, the circuits of the TMC16 must,
in principle, be configured in such a way that the last digit is not
transmitted until expiry of the WE1A timer (this is necessary as no answer
is transmitted by the trunk and especially necessary in the case of Automatic
Subscriber-Stations which report immediately upon dialing and subsequently
expect DTMF post-dialing). If absolutely all digits are to be transmitted
prior to expiry of the WE1A timer, the COP parameter NO1A (Without Signaling
Method 1A) must be set in the circuit. Another possibility of completing
dialing immediately is to complete the dialing with "#" , or
to administrate the AMO LDPLN with "z" instead of "x"
(the circuit is consequently not seized at all until after the final
digit has been transmitted).