Collapse AllExpand All

5.6.9.1. Configuration of 'Partial-integration-RG' solution Previous topic Parent topic Child topic Next topic

  • Configuration of 'Partial-integration-RG' solution
  • Configuration of DIUS2
    The DIUS2 is configured identical to other DIUS2 in system (e.g. for CORNET-NQ networks). The DIUS2-Loadware need not be informed by AMO LWPAR, that a PBXXX is connected to it. The OpenScape 4000 switch gets the reference clock directly from the DIUS2. Therefore if PBXXX is connected to a DIUS2, the LWPAR-Parameter CDG=NO has to be configured for the DIUS2. AMO commands (applicable to an empty Database, important commands are shown bold):
    Please pay attention to the functional id of the PBXXX
  • Configuration of the PBXXX board as 'Ring Generator':
    ADD-BCSU:MTYPE=RG, LTG=1, LTU=1, SLOT=67, PARTNO="Q6401-X", FCTID=1;
    
  • Configuration of DIUS2
    • DIMSU configuration for DIUS2 (all dimsu needed for DIUS2)
      ADD-DIMSU:TYPE=ADMCC, CCIDXS=2000; 
      
      ADD-DIMSU:TYPE=BASIC, LODEN=2000, PRI=20, TRK=100, SG=100, 
      NWBCHL=600, CRCP=50, DPLNCD=800, ....; 
      
      ADD-DIMSU:TYPE=SYSTEM, PERMDL=100, ..; 
    • Configuration fo LTG, LTU and DIUS2
      ADD-UCSU:UNIT=LTG, LTG=1, SIPARTNO="Q2234-X "; 
      
      ADD-UCSU:UNIT=LTU, LTG=1, LTU=1, LTPARTNO="Q2248-X"; 
      ADD-BCSU:MTYPE=DIU, LTG=1, LTU=1, SLOT=61, PARTNO="Q2096-X200",  LWVAR=0;
    • Basic configuration of LCR
      ADD-WABE:CD=19, DAR=OWNNODE; 
      
      ADD-WABE:CD=16, DAR=TIE; 
      
      CHANGE-ZAND:TYPE=ALLDATA, NNO=100, NODECD=19; 
      
      ADD-COP:COPNO=5; 
      
      ADD-COT:COTNO=20; 
      
      ADD-BUEND:NO=30, TGRP=23, NAME="QV-DPNSS1"; 
      
      CHANGE-LWPAR:TYPE=DIUS2, BLNO=2, CDG=N; /* CDG MUST BE SET TO "NO" */
    • Configuration of trunk (use a proper LCOSS and LCOSD to get the necerssary access and a node number )
      ADD-TDCSU:OPT=NEW, PEN=1-1-061-00, BCGR=1, CCT="CDG-DPNSS1", 
      COTNO=20, COPNO=5, LCOSV=1, LCOSD=1, PROTVAR=ECMAV2, DEV=S2CONN, 
      TGRP=23, LWPAR=2; 
      
      CHANGE-REFTA:TYPE=CIRCUIT, PEN=1-1-061-00, PRI=80;
      OpenScape 4000 can accept the clock from DPNSS1 (depending on prio and error counters) And if the circuit is configured through CDGM to retrieve th clock from DPNSS/DASS
      OR
      OpenScape 4000 does not accept clock from DPNSS-Network but delivers it (PRIO=0) (for details see also Section 46.5.6, "Network Clock Supply"). OpenScape 4000 should always accept the clock from a DASS circuit and never deliver it.