Collapse AllExpand All

5.12.5.2. A station number verification (screening) Previous topic Parent topic Child topic Next topic

  • Station number verification is not required for this function and need only be configured if necessary.
  • Configuration of the number verification for TON=Subscriber If required, separate SCREEN data must be configured for TON=national and international.
  • A station number from 0000 to 9999 are transmitted in TON=Subscriber.
    ADD-SCREN:TYPE=SCRPATT, SCRPPLAN=1, SCRP=78070XXXX;
    
  • The default station number (DNO) is expanded by the ATND code (0) of the external PBX.
    EINR-SCREN:ART=SCRDATEN, UKNNR=1-89-410, DRNR=780700, DRNRTYP=SUBSCR, 
    ARNRTYP=SCREEN, ARNRANZ=CLIPSTD, BRNRTYP=KEINSCR, BRNRANZ=COLPSTD, 
    SCRPPLAN=1, SCRPTYP=SUBSCR;