Collapse AllExpand All

5.18.3.1. Identification With Master Number (Outgoing Seizure) Previous topic Parent topic Child topic Next topic

Instead of the station number, the master number is sent to the remote central office if:
  • the station is blocked for direct inward dialing,
  • the number is identified as 'Presentation restricted' (for example, a secret calling number),
  • the A number is not available (for example, because of an analog network interface),
  • the A number is identified as inadmissible (screening indicator: Screened but failed),
  • the attendant console sets up the connection (does not apply to seizure of the line with the P aggregate).
You must configure the master number in MFCTA. If you have not configured a calling number, the central office acknowledges the A number request with the ID contents.
  • Configure the master number as follows:
    CHANGE-MFCTA:MFCVAR=x,TYPE=TBLF,OPT=FIDENT,
    BSDIRNO=master-number;
    
    CHANGE-MFCTA:MFCVAR=x,TYPE=TBLF,OPT=FIDENT,
    BSDIRCNT=number-of-digits-in-master-number;