You can set the parameter MFCMO in MFCTA. The parameter NOMFCMO must
not be set. With this combination of the parameters, each terminating
connections generates a F5607 MFC-MONITORING.
This is implemented for testing cases. Here two examples:
F5607 M4 N0198 NO ACT BPA CIRCUIT MFC MONITORING 03-01-16 08:50:29
ALARM CLASS:SWU-PER:013/000/001
P102:LTG1 :LTU2 :037: 37 : 0 Q2196-X DIU-N2/2 BST:01 PLS:-03
FORMAT:22 DEVICE NAME: DIUCQ421
402C2000C100020000000F0F00000301 050202030205070F0405070100000000
0000000F020101050505050505050505 010101030600000000000000B4050000
17FFFFFFFFFFFFFFFFFFFFFFFFFFFFFF FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
FFFFFFFFFF
F5607 M4 N0199 NO ACT BPA CIRCUIT MFC MONITORING 03-01-16 11:11:35
ALARM CLASS:SWU-PER:013/000/001
P102:LTG1 :LTU2 :037: 38 : 0 Q2196-X DIU-N2/2 BST:01 PLS:-03
FORMAT:22 DEVICE NAME: DIUCQ421
402C20008100020000000F0F00000301 050202030205070F0406020100000000
0000000F020101050505050505050505 010101030500000000000000B5050000
17FFFFFFFFFFFFFFFFFFFFFFFFFFFFFF FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
FFFFFFFFFF
Interpretation of example one:
The decribed rules of the chapter above are valid. The ii-part shows
the signals received from the originating register. The mm-part shows
the signals send to the originating register.
ii: 03 01 05 02 02 03 02 05 07 0F 04 05 07 01
mm: 05 05 05 05 05 05 05 05 05 01 01 01 03 06
You see the signals by using ANI before the transmission of the B-number. For ANI
is the A-5
used. First A-5 ask calling partys category.
A-Number: 5223257F; B-Number: 3457; calling partys category: II-1
The called party is free (B-6)
The second example shows nearly the same, but the called party (3462)
is out of service (B-5).