5.18.3.7.1. F5607 MFC-MONITORING for all terminating connections Previous topic Parent topic Child topic Next topic

You can set the parameter MFCMO in MFCTA. The parameter NOMFCMO must not be set. With this combination of the parameters, each terminating connections generates a F5607 MFC-MONITORING.
This is implemented for testing cases. Here two examples:
F5607 M4 N0198 NO ACT   BPA   CIRCUIT  MFC MONITORING          03-01-16 08:50:29
       ALARM CLASS:SWU-PER:013/000/001
       P102:LTG1 :LTU2 :037: 37    : 0 Q2196-X    DIU-N2/2   BST:01  PLS:-03
       FORMAT:22      DEVICE NAME:  DIUCQ421
       402C2000C100020000000F0F00000301  050202030205070F0405070100000000
       0000000F020101050505050505050505  010101030600000000000000B4050000
       17FFFFFFFFFFFFFFFFFFFFFFFFFFFFFF  FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
       FFFFFFFFFF

F5607 M4 N0199 NO ACT   BPA   CIRCUIT  MFC MONITORING          03-01-16 11:11:35
       ALARM CLASS:SWU-PER:013/000/001
       P102:LTG1 :LTU2 :037: 38    : 0 Q2196-X    DIU-N2/2   BST:01  PLS:-03
       FORMAT:22      DEVICE NAME:  DIUCQ421
       402C20008100020000000F0F00000301  050202030205070F0406020100000000
       0000000F020101050505050505050505  010101030500000000000000B5050000
       17FFFFFFFFFFFFFFFFFFFFFFFFFFFFFF  FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
       FFFFFFFFFF


Interpretation of example one:
The decribed rules of the chapter above are valid. The ii-part shows the signals received from the originating register. The mm-part shows the signals send to the originating register.
ii: 03 01 05 02 02 03 02 05 07 0F 04 05 07 01
mm: 05 05 05 05 05 05 05 05 05 01 01 01 03 06
You see the signals by using ANI before the transmission of the B-number. For ANI is the A-5 used. First A-5 ask calling partys category.
A-Number: 5223257F; B-Number: 3457; calling partys category: II-1
The called party is free (B-6)
The second example shows nearly the same, but the called party (3462) is out of service (B-5).