5.18.3.7. Note on Message F5607 MFC-MONITORING Previous topic Parent topic Child topic Next topic

This (error) message contains various information:
Example for message F5607:
F5607 M4 N0203 NO ACT   BPA   CIRCUIT  MFC MONITORING          03-01-16 11:42:58
       ALARM CLASS:SWU-PER:013/000/001
         P102:LTG1 :LTU2 :037: 38    : 0 Q2196-X    DIU-N2/2   BST:01  PLS:-03
       FORMAT:22      DEVICE NAME:  DIUCQ421
       402C0100100000000000010100000000  00000000000000000000000000000000
       00000002010101050000000000000000  000000000000000000000000B5050000
       15FFFFFFFFFFFFFFFFFFFFFFFFFFFFFF  FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
       FFFFFFFFFF
Interpretation of the message contents:
1st line:
402C0200100000008000010100010000  00000000000000000000000000000000
aabbccddeeeeeeeeeeeeffgghhiiiiii  iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
2nd line
00000001000001000000000000000000  000000000000000000000000B8000000 
iiiiiijjkkllmmmmmmmmmmmmmmmmmmmm  mmmmmmmmmmmmmmmmmmmmmmmmnnnnnnnn
3rd line
0EFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF  FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
ooxxxxxxxxxxxxxxx
aa
Message length H'40 = 64 relevant bytes
bb
Message code = DB_QF_E_CIR_MFC_UEBERW = MFC-Monitoring
cc
Situation (see below) here: 01 = No first signal
dd
Pending frequencies on the SIU (only for SIU developers)
ee
MFC attribute (only for DH developers)
ff
Forward signal input counter
gg
Forward signal output counter
hh
Forward signal retrieval pointer (not important)
ii
Forward signal
jj
Backward signal input counter
kk
Backward signal output counter
ll
Backward signal retrieval pointer
mm
Backward signal
nn
Device address of the connected SIU type 3
oo
DH status
xx
Data that is no longer important
The situation is stored in the 3rd byte (in this case 02). The following values are possible:
00
no SIU found
01
No first signal
02
No further signal
03
Pending signal does not deactivate
04
No control frequency (SOCOTEL/IBERCOM)
05
Control frequency does not deactivate
06
SIU does not answer message (request for pending frequencies)
07
Signal that is not allowed (NOPO in table
08
Forward signal not acknowledged (generated connection)
09
Forward signal not acknowledged (generated connection)
0A
COE error. Line has incorrect or missing class of externals assigned.
The F5607 with situation 0A is also used for trunks without MFC-Table
0B
Implausible MFC signal start
0C
Implausible MFC signal end
0D
Implausible timer
0E
Test call 1
0F
Test call 2
10
Other situation (not assigned)
11
Test call 3
12
No SIU request message (MFRP)
13
Invalid SIU frequency (MFRP)
14
Unexpected 1st frequency (MFRP)
15
Incorrect program progress (MFRP)
16
Congestion signal (MFRP)
17
Long timer responds (terminating connection MFRP)
18
Long timer responds (generated connection MFRP)
19
Error during MFRP generated connection
1A
Codogram (not sended by ANIF / no receiver by ANIB)
1B
Error during MFRP generated connection
1C
Error during MFRP generated connection (not allowed parameter combination)
1D
Error during MFRP generated connection (no attribute set)
1E
Error during MFRP generated connection (unlogical parameters, attribute)
1F
end to end signalling
20
link-by-link Signalling (see )