Example for configuring a subscriber with an NI BRI data device (directly connected to the SLMO port) in a PBX system:
  • If no SLMO port is available (module not configured or no free ports)
    ADD-BCSU:MTYPE=PER,(LTG=1,)LTU=5,SLOT=73,PARTNO="Q2158-X";
    
  • Configure an Opti connection: optiset E-Master 3160 connected directly to the SLMO */
    ADD-SBCSU:SSTNO=3160,OPT=OPTI,CONN=DIR,PEN=1-5-73-06,
    DVCFIG=OPTISET,COS1=5,COS2=6,LCOSV1=11,LCOSV2=12,LCOSD1=21
    ,LCOSD2=22;
    
  • To extend this Opti connection: S0 bus 3168 with NI BRI data device
    IMPORTANT:
    The system automatically configures the TA S0 that you must install for connecting S0 devices in Optiset E-Master 3168.
    ADDSBCSU:SSTNO=3168,OPT=OPTIEXP,MAINO=3160,DVCFIG=SET600&DTE,
    COS1=5,COS2=6,LCOSV1=11,LCOSV2=12,LCOSD1=21,LCOSD2=22,SPROT=S
    BNIBRI,DPROT=SBNIBRI,SOPTIDX=7,DOPTIDX=7,BASICSVC=UDI64;
    
  • Configure MSN 3169 (with reference to the S0 bus 3168) for the Opti connection.
    IMPORTANT:
    The NI BRI protocol set for the S0 bus 3168 is also automati­cally used for all accompanying MSNs and can be changed only for the 3168.
    ADDSBCSU:SSTNO=3169,OPT=MSN,MAINO=3168,
    BASICSVC=UDI64&UDI64;
    
  • Opti connection configuration: OptiPoint-Master 3170 and PC with ISDN application connected directly to the SLMO.
    IMPORTANT:
    The system automatically configures the USB adapter that is needed for the PC connection and that is integrated in the OptiPoint-Master 3178.
    ADD-SBCSU:SSTNO=3170,OPT=OPTI,CONN=DIR,PEN=1-5-73-07,
    DVCFIG=OPTI500&DTE,COS1=5,COS2=6,LCOSV1=11,LCOSV2=12,
    LCOSD1=21,LCOSD2=22,DPROT=SBNIBRI,DOPTIDX=7,BASICSVC=UDI64;