5.26.4.4. AMOs LWPAR & SYSPAR Previous topic Parent topic Child topic Next topic

The AMOs LWPAR and SYSPAR are used to set parameters effecting synchronization. The "Master" parameter, however, is not used for synchronization but for master/slave assignment for layer 2.
The "SMD" parameter, on the other hand, effects synchronization. If SMD = YES this record will never supply the reference clock, even though it has a certain priority in the REFTA and would have been selected by the safety equipment.