5.37.2.7. Activation/Deactivation of Boards and Circuits Previous topic Parent topic Child topic Next topic

VCM board and circuit:

The VCM board and circuit can be switched like all other boards and circuits with the AMOs BSSU and DSSU.

Partner board and circuit:

In case of pre-blocking of a S0/S2 board or S0/S2 circuit the AMOs BSSU and DSSU check if B-channels are occupied by VC and if so the affected VCM boards or circuits will be pre-blocked too. During activation the occupation by VC will be also checked. If the determined VCM boards or circuits are in a pre-blocked status, they will be activated too.
INFO:
After deactivation of a LTU the status "pre-blocked" of boards and circuits is lost. In this case the automatically pre-blocked VCM boards or circuits have to be activated manually.