Collapse AllExpand All

9.2.3. Combination Code (FAX, DTE) Previous topic Parent topic Child topic Next topic

  • Configure the DAR in the DPLN as follows:
    Combination code for FAX
    ADD-WABE:CD=key-num,DAR=FAXNO;
    
    or
    Combination code for DTE
    ADD-WABE:CD=key-num,DAR=DTENO;
    
  • Configure number conversion as follows:
    ADD-RUFUM:TYPE=COMB,FAX1=number,FAX2=number;  or 
    
    ADD-RUFUM:TYPE=COMB,DTE1=number,DTE2=number;
    
    FAX1, DTE1 correspond to the combination codes (FAXNO, DTENO) in digit analysis. FAX2, DTE2 correspond to the station numbers of the devices in OpenScape 4000
    IMPORTANT:
    Conversion is not possible if the station numbers are identical in the AMO RUFUM, for example, for the parameters FAX1 and FAX2. It is not necessary either because dialing the combination code always sets up a connection to the device with the same station number. All you have to do is set the station number 4711 to DAR=FAXNO under CPS 6 in WABE and set 4711 to DAR=STN for the other CPSs. If the fax device is configured under 4711, it is reached (even if number conversion is not performed) by dialing 4711 in CPS 6 (exchange indial) under DAR=FAXNO.