DB calculates the percentage of usage of the DIMSU parameters and sends a message to SysDep to generate an alarm when 90%, 100% are used or 10% are free again. To avoid an overflow of messages only one 90%-message is sent. This is triggered by a flag per parameter. For this purpose 256 bytes of DB_D_RESERVE_CC_TBL (10) are used.
The flags are reset after a restart (reload, hard restart or soft restart). That means that the alarm messages could occur again, when the DIMSU parameter are used although they has been sent already before the restart.
If the value of a DIMSU parameter is changed by AMO DIMSU the flags are reset. The alarm message could occur again afterwards.
The existing SWU central alarm 24 (SYSTEM MESSAGES) will be assigned to the DIMSU warning messages. The error counter of this alarm will be incremented by 8 in case of 90% DIMSU parameter usage, by 10 in case of 100% usage and it will be reset to 0 if 10% are free again. After proper setting of VADSU (see administration part) this results minor, major or no alarm depending on the DIMSU warning messages.

Examples for the alarm messages are:

  • Minor alarm:
    F4016 M4 N0062 NO ACT BPA DB ADVISORY 06-11-23 13:35:16 
    ALARM CLASS:CENTRAL:024 
    FORMAT:33 
    90% OF DIMSU PARAMETER ORG/ORG USED 
    
  • Major alarm:
    F4016 M4 N0063 NO ACT BPA DB ADVISORY 06-11-23 13:40:59 
    ALARM CLASS:CENTRAL:024 
    FORMAT:33 
    100% OF DIMSU PARAMETER ORG/ORG USED 
    
  • No alarm (alarm is reset):
    F4016 M4 N0064 NO ACT BPA DB ADVISORY 06-11-23 13:46:25 
    ALARM CLASS:CENTRAL:024 
    FORMAT:33 
    10% OF DIMSU PARAMETER ORG/ORG AVAILABLE AGAIN