27.2.2
CHANGE-BCSU
Modification of module data.
•
It is only possible to change code numbers of modules within the same module-line-type (e.g. SLMA).
Exception: The change of some boards with newer HW modules is possible even though the module-line-type is different and is handled AMO internally (e.g. STMD<->STMD2, SLMS<->SLMS2, DIUS2<->DIUN2,...).
If the module is not already blocked, the AMO blocks it. After the change is carried out, the module is put back into service.
•
In the case of a DIUC, the parameters FIDX1/2 and LWPAR1/2 of the associated PCM paths can be modified.
•
With the new branch "HWYBDL" the access to the upper (F) or lower (A) highwaybundle of a board can be set, to use a previously by AMO UCSU configured overlay configuration. At the moment, bundle "F" can only be used for STMI, DIUN2- and DIUN4 boards.
•
With the new branch "HWYBDL" the number of usable b-channels can be reduced and also reset to the original value for each configured function on the HG3500 board, respectively the pre-reserved amount of circuits (for trunks) and/or b-channels (for subscribers) can be re-configured to usable circuits/b-channels.
The calculation of values for automatic b-channel reduction is always done if a value is specified for the according parameter - but it is not possible to configure more than the maximum possible values.
Procedure Overview
Command Code
Parameter
CHANGE-BCSU
TYPE=PARTNO,[LTG=<number>],[LTU=<number>]
,[SLOT=<number>],[PARTNO1=<string>]
,PARTNO2=<string>,[FCTID1=<number>]
,[FCTID2=<number>],[ALARMNO=<number>];
|TYPE=DIU,[LTG=<number>],LTU=<number>
,SLOT=<number>,{(min 1)LWPAR1=<string>,FIDX1=<string>
,LWPAR2=<string>,FIDX2=<string>};
|TYPE=SIGNOFF,[LTG=<number>],LTU=<number>,SLOT=<number>
,[CCT=<number>],[TSI=<number>],[DEVTYPE=<param>]
,[COFIDX=<number>],[OPS=<param>];
|TYPE=RELEASE,[LTG=<number>],LTU=<number>,SLOT=<number>
,[CCT=<number>],[TSI=<number>];
|TYPE=FLOWCTRL,[LTG=<number>],[LTU=<number>]
,[SLOT=<number>],[ACTFC=<number>],[STERM=<number>]
,[LTERM=<number>],[PTERM=<number>];
|TYPE=HPA,[LTG=<number>],LTU=<number>
,SLOT=<number>,[MACADDR=<hex>]
,[TDMLAW=<number>];
|TYPE=HWYBDL,[LTG=<number>],[LTU=<number>]
,[SLOT=<number>],PARTNO=<string>
,[FCTID1=<number>],[HWYBDL=<param>];
|TYPE=TMD,[LTG=<number>],LTU=<number>
,SLOT=<number>,[LWPAR=<number>],[FIDX=<string>];
|TYPE=IPGW,[LTG=<number>],LTU=<number>
,SLOT=<number>,[IPADDR=<number>]
,[BCHL3530=<number>],[BCHLSIP=<number>]
,[BCHL3550=<number>],[BCHLWAML=<number>]
,[BCHL3570=<number>],[CHNGRSL=<number>];
Examples
1.
Change the SLMA module with the code number Q2041-X and the parameters LTG=1, LTU=1, SLOT=31 to an SLMA module with the code number Q2057-X100.
Input:
CHANGE-BCSU:PARTNO,1,1,31,,"Q2057-X100";
2.
Change all SLMA modules of LTG 1 with the code number Q2041-X to SLMA modules with the code number Q2057-X100.
Input:
CHANGE-BCSU:PARTNO,1,,,"Q2041-X","Q2057-X100";
Output:
H01: BG 1.1. 25 CHANGED - IN SERVICE
H01: BG 1.1. 31 CHANGED - OUT OF SERVICE (NPR)
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
3.
Change the highwaybundle of a DIUN2 to bundle "F":
CHANGE-BCSU:HWYBDL,1,1,37,Q2196-X,1,F;
4.
Change pre-reserved trunk circuits to configurable HG3550 circuits for IP gateway by means of parameter CHNGRSL.
Prerequists are pre-reserved HG3550 circuits:
ADDRESS : LTG 1 LTU 3 SOURCE GROUP 1 ALARMNO-LTU 0
-----+-----------+--------+---+-+-+---+-+------------+------------+------------
| | | |S|H|AL-|N| | |
| ASSIGNED | MODULE |FCT|E|W|ARM|P| INSERTED | HW- | MODULE
PEN | MODULE | TYPE |ID |C|Y|NO |R| MODULE |STATE INFO | STATUS
-----+-----------+--------+---+-+-+---+-+------------+------------+------------
55 | Q2324-X510 STMI4 1 * A 0|*| UNKNOWN | | UNACH
+--------------------------------+-+------------+------------+------------
| IP ADDRESS : 192.168. 11. 55 B-CHANNELS : 120 BCHLCNT : 120
| BLOCK NO : 11 PRERESERVED LINES ASSIGNED : NO
| 1. FUNCT : HG3570 1 LINES B-CHANNELS : 21 BCHLCNT : 21
| 2. FUNCT : HG3530 70 LINES B-CHANNELS : 59 BCHLCNT : 59
| 3. FUNCT : HG3550 1 LINES B-CHANNELS : 10 BCHLCNT : 10
| 4. FUNCT : HG3550R 3 LINES B-CHANNELS : 30 BCHLCNT : 30
| SECURITY STATUS: 1:[ ] 2:[ ] 3:[ ] 4:[ ] 5:[ ] 6:[ ] 7:[ ] 8:[ ]
| (SEE BOTTOM) 9:[ ] 10:[ ] 11:[ ] 12:[ ] 13:[ ] 14:[ ] 15:[ ] 16:[ ]
+--------------------------------+-+------------+------------+------------
Input:
CHA-BCSU:IPGW,1,3,55,,,,,,,2;
Result:
ADDRESS : LTG 1 LTU 3 SOURCE GROUP 1 ALARMNO-LTU 0
-----+-----------+--------+---+-+-+---+-+------------+------------+------------
| | | |S|H|AL-|N| | |
| ASSIGNED | MODULE |FCT|E|W|ARM|P| INSERTED | HW- | MODULE
PEN | MODULE | TYPE |ID |C|Y|NO |R| MODULE |STATE INFO | STATUS
-----+-----------+--------+---+-+-+---+-+------------+------------+------------
55 | Q2324-X510 STMI4 1 * A 0|*| UNKNOWN | | UNACH
+--------------------------------+-+------------+------------+------------
| IP ADDRESS : 192.168. 11. 55 B-CHANNELS : 120 BCHLCNT : 120
| BLOCK NO : 11 PRERESERVED LINES ASSIGNED :
YES
| 1. FUNCT : HG3570 1 LINES B-CHANNELS : 21 BCHLCNT : 21
| 2. FUNCT : HG3530 70 LINES B-CHANNELS : 59 BCHLCNT : 59
| 3. FUNCT : HG3550 3 LINES B-CHANNELS : 30 BCHLCNT : 30
| 4. FUNCT : HG3550R 1 LINES B-CHANNELS : 10 BCHLCNT : 10
| SECURITY STATUS: 1:[ ] 2:[ ] 3:[ ] 4:[ ] 5:[ ] 6:[ ] 7:[ ] 8:[ ]
| (SEE BOTTOM) 9:[ ] 10:[ ] 11:[ ] 12:[ ] 13:[ ] 14:[ ] 15:[ ] 16:[ ]
+--------------------------------+-+------------+------------+------------
5.
Manual reduction of b-channels. In this example the number of b-channels is reduced for HG3530 but set to the for each function in maximum possible value for HG3550 and HG3550-WAML (not configured).
Input:
CHA-BCSU:IPGW,1,3,55,,40,,120,120;
Output:
H31: THE AMOUNT OF AVAILABLE B-CHANNELS ON CGW BOARD HAS BEEN CHANGED !
PLEASE CHECK THE RESOURCE MANAGER CONFIGURATION (ALSO AMO-CGWB)
H32: IF THE B-CHANNEL PARAMETER IS SPECIFIED, THE AVAILABLE B-CHANNELS ON CGW
FUNCTIONS IS SMALLER/EQUAL AS THE CONFIGURED VALUES FOR CGW FUNCTIONS !
THE RESOURCE MANAGEMENT IS ALSO AFFECTED BY SPECIFIYING THIS
PARAMETER, THEREFORE FEWER B-CHANNELS WILL BE CONFIGURED IN TOTAL.
H39: THE PARAMETERS FOR CHANGING THE NUMBER OF B-CHANNELS WILL BE IGNORED IF
THE ACCORDING FUNCTION IS NOT CONFIGURED.
H35: THE PROCESSED CHANGES HAVE NEEDED A DEACTIVATED STMI BOARD.
THE BOARD IS INITIATED TO BE TAKEN IN SERVICE AGAIN RIGHT NOW.
Result:
ADDRESS : LTG 1 LTU 3 SOURCE GROUP 1 ALARMNO-LTU 0
-----+-----------+--------+---+-+-+---+-+------------+------------+------------
| | | |S|H|AL-|N| | |
| ASSIGNED | MODULE |FCT|E|W|ARM|P| INSERTED | HW- | MODULE
PEN | MODULE | TYPE |ID |C|Y|NO |R| MODULE |STATE INFO | STATUS
-----+-----------+--------+---+-+-+---+-+------------+------------+------------
55 | Q2324-X510 STMI4 1 * A 0|*| | | NPR
+--------------------------------+-+------------+------------+------------
| IP ADDRESS : 192.168. 11. 55 B-CHANNELS : 120 BCHLCNT :
101
| BLOCK NO : 11 PRERESERVED LINES ASSIGNED : YES
| 1. FUNCT : HG3570 1 LINES B-CHANNELS : 21 BCHLCNT : 21
| 2. FUNCT : HG3530 70 LINES B-CHANNELS : 59 BCHLCNT : 40
| 3. FUNCT : HG3550 3 LINES B-CHANNELS : 30 BCHLCNT : 30
| 4. FUNCT : HG3550R 1 LINES B-CHANNELS : 10 BCHLCNT : 10
| SECURITY STATUS: 1:[ ] 2:[ ] 3:[ ] 4:[ ] 5:[ ] 6:[ ] 7:[ ] 8:[ ]
| (SEE BOTTOM) 9:[ ] 10:[ ] 11:[ ] 12:[ ] 13:[ ] 14:[ ] 15:[ ] 16:[ ]
+--------------------------------+-+------------+------------+------------
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.