To replace an STMI/STMI2/STMI4 board please note the following:
- Replace a “small“ STMI/STMI2/STMI4 with a “small“ STMI/STMI2/STMI4:
no problem
- Replace a “large“ STMI/STMI2/STMI4 with a “large“ STMI/STMI2/STMI4:
no problem
- Replace a “small“ STMI/STMI2/STMI4 with a “large“ STMI/STMI2/STMI4:
no problem
- Replace a “large“ STMI/STMI2/STMI4 with a “small“ STMI/STMI2/STMI4:
only works if not more than 60 b-channels are used
Procedure:
- Change the board.
- It is not necessary to delete all circuits on the module and the
module itself, but rather to change the part number with CHANGE-BCSU
(if necessary).
CHANGE-BCSU:TYPE=PARTNO,LTG=<ltg>,LTU=<ltu>,SLOT=<slot>,PARTNO1=<part number of
board to be changed>,PARTNO2=<part number of new board>;
RESTART-BSSU:ADDRTYPE=PEN,LTG=<ltg>,LTU=<ltu>,SLOT=<slot>;
SIP profile configuration including credentials for SIP
Provider (where used) are stored on board/hardware (i.e. STMI2/STMI4/STMIX/STMIY
and vSTMI on SoftGate). Please be aware when exchanging hardware to consider
a “Factory Reset” from Web-Based Management prior to exchanging the
board to ensure all private data is removed.
INFO:
Prior to this step is recommended to perform a HG3500 Backup to
ensure the old data remains available for the new board that will be
used.