2.8.5. Service steps after the automatic switch over Previous topic Parent topic Child topic Next topic

Two steps can be different after a switch over in case of error:
  1. The subscribers which are switched over should get their original pens.
  2. In this case the board pool has to be defined as HOPAUT=SINGLE!
    • Change the defective board resp. reconnect the LAN connection.
    • Switch back the subscribers with the AMO command
    RESTART-BSSU:ADDRTYPE=PEN,LTU=xx,SLOT=xx,CGWSW=CGWSWBCK;
    (xx -> Pen of the board with status STDBYDEF)
    • Reset the history data of the Board Pool:
    CHANGE-BPOOL:MTYPE=CGW,TYPE=HISTRES,LTU=y,SLOT=zz;
  3. The subscribers which are switched over should remain on the new pens.
  4. In this case the board pool has to be defined as HOPAUT=MULTI!
    • Change the defective board resp. reconnect the LAN connection.
    • Switch the STDBYDEF board to STDBYRDY with the AMO command
    RESTART-BSSU:ADDRTYPE=PEN,LTU=xx,SLOT=xx,CGWSW=STBYRDY;