BLOCK |
temporary blocking of trunk as reference clock supplier |
|
|
Type of Input: |
single value, 2. parameter of a min-1-group |
(CHANGE,TYPE=CIRCUIT-normal circuits or boards with cable interface / CHANGE,TYPE=FRONT-front reference)
|
|
|
single value, optional |
(ADD,TYPE=CIRCUIT-normal circuits or boards with cable interface / ADD,TYPE=FRONT-front reference)
|
|
|
Possible Values: |
N |
no |
|
|
|
Y |
yes |
|
|
CLASS |
class of clock generator |
|
|
Type of Input: |
single value, mandatory |
(CHANGE,TYPE=AECB-external clock box)
|
|
|
single value, optional |
(ADD,TYPE=AECB-external clock box)
|
|
|
Possible Values: |
numeric, 0-255 |
|
|
DIALOG01 |
hidden action: dialog01, acknowledge for change (y/n) |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
N |
no |
|
|
|
Y |
yes |
|
|
DIALOG02 |
hidden action: dialog02, acknowledge for delete (y/n) |
|
|
Type of Input: |
single value, mandatory |
|
|
Possible Values: |
N |
no |
|
|
|
Y |
yes |
|
|
ERROR |
error counter; standard value is 16000 |
|
|
Type of Input: |
single value, 3. parameter of a min-1-group |
(CHANGE,TYPE=FRONT-front reference)
|
|
|
single value, 4. parameter of a min-1-group |
(CHANGE,TYPE=CIRCUIT-normal circuits or boards with cable interface)
|
|
|
Possible Values: |
numeric, 0-65535 |
|
|
KIND |
type of output (all,act) |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
ACT |
actual reference clock supplier |
|
|
|
ALL |
all reference clock circuits |
|
|
LTU |
LTU number |
|
|
Type of Input: |
single value, 4. parameter of a min-1-group |
(CHANGE,TYPE=FRONT-front reference)
|
|
|
single value, optional |
(ADD,TYPE=FRONT-front reference / DELETE,TYPE=FRONT-front reference / DISPLAY,TYPE=FRONT-front reference / REGENERATE,TYPE=FRONT-front reference)
|
|
|
Possible Values: |
numeric, 0, 17-99 |
|
|
PEN |
port equipment number: ltg-ltu-slot-cct |
|
|
Type of Input: |
0 to 4 single values, concatenated with -, optional |
(DISPLAY,TYPE=CIRCUIT-normal circuits or boards with cable interface / REGENERATE,TYPE=CIRCUIT-normal circuits or boards with cable interface)
|
|
|
4 single values, concatenated with -, mandatory |
(ADD,TYPE=CIRCUIT-normal circuits or boards with cable interface / CHANGE,TYPE=CIRCUIT-normal circuits or boards with cable interface / DELETE,TYPE=CIRCUIT-normal circuits or boards with cable interface)
|
|
|
Possible Values: |
numeric, 0-121 |
|
|
PRI |
priority of trunk for reference clock selection |
|
|
Type of Input: |
single value, 1. parameter of a min-1-group |
(CHANGE,TYPE=CIRCUIT-normal circuits or boards with cable interface / CHANGE,TYPE=FRONT-front reference)
|
|
|
single value, optional |
(ADD,TYPE=CIRCUIT-normal circuits or boards with cable interface / ADD,TYPE=FRONT-front reference)
|
|
|
Possible Values: |
numeric, 0, 11-90 |
|
(ADD,TYPE=CIRCUIT-normal circuits or boards with cable interface / CHANGE,TYPE=CIRCUIT-normal circuits or boards with cable interface)
|
|
|
numeric, 11-90 |
|
(ADD,TYPE=FRONT-front reference / CHANGE,TYPE=FRONT-front reference)
|
|
READYASY |
ready but asynchronous |
|
|
Type of Input: |
single value, 3. parameter of a min-1-group |
(CHANGE,TYPE=CIRCUIT-normal circuits or boards with cable interface)
|
|
|
single value, optional |
(ADD,TYPE=CIRCUIT-normal circuits or boards with cable interface)
|
|
|
Possible Values: |
N |
no |
|
|
|
Y |
yes |
|
|
SRCGRP |
source group number |
|
|
Type of Input: |
single value, optional |
|
|
Possible Values: |
numeric, 1-255 |
|
|
TYPE |
entry type of reference clock |
|
|
Type of Input: |
single value, mandatory |
(ADD / CHANGE / DELETE)
|
|
|
single value, optional |
(DISPLAY / REGENERATE)
|
|
|
Possible Values: |
AECB |
external clock box |
|
|
|
CIRCUIT |
normal circuits or boards with cable interface |
|
|
|
FRONT |
front reference |
|
|
|
SRCGRP |
source group |
|
(DISPLAY)
|
| F01 | F01: CIRCUIT DOES NOT EXIST IN THE REFERENCE CLOCK TABLE |
| F02 | F02: PEN ERROR; SLOT FORMALLY INCORRECT |
| F03 | F03: PEN ERROR; PERMISSIBLE RANGE FOR CIRCUIT NO.: 0 - @@ |
| F04 | F04: TMX21 MODULE; PERMISSIBLE RANGE FOR CIRCUIT NO.: 0 - @@ |
| F05 | F05: DIUC64 MODULE; PERMISSIBLE VALUES FOR CIRCUIT NO.: 0 OR 32 |
| F05 | F05: DIUC MODULE; PERMISSIBLE VALUE FOR CIRCUIT NO.: 0 |
| F06 | F06: DIUS2 MODULE; PERMISSIBLE RANGE FOR CIRCUIT NO.: 0 - @@ |
| F07 | F07: CDG MODULE; PERMISSIBLE RANGE FOR CIRCUIT NO.: 0 - @@ |
| F08 | F08: PNEDIUS2 MODULE; PERMISSIBLE RANGE FOR CIRCUIT NO.: 0 - @@ |
| F11 | F11: LTG @@ NOT ASSIGNED |
| F12 | F12: LTG @@: LTU @@ NOT ASSIGNED |
| F13 | F13: PEN ERROR; PERMISSIBLE RANGE FOR LTG: 1 - @@ |
| F14 | F14: PEN ERROR; PERMISSIBLE RANGE FOR LTU: 1 - 15, 17-99 |
| F15 | F15: REFERENCE CLOCK CIRCUIT IS REFERENCE CLOCK SUPPLIER; BLOCK FIRST
(AMO REFTA) |
| F16 | F16: REFERENCE CLOCK TABLE IS FULL. INSUFFICIENT MEMORY SPACE (AMO DIMSU:
PARAMETER TRK) |
| F17 | F17: PEN NOT SPECIFIED AT THE PHYSICAL MODULE LOCATION,
POSSIBLE INPUT: @@-@@-@@@-@@ |
| F18 | F18: INSUFFICIENT MEMORY SPACE (AMO DIMSU: PARAMETER TRK) |
| F19 | F19: THE CIRCUIT MUST BE DEACTIVATED (AMO DSSU) |
| F20 | F20: NO MODULE CONFIGURED AT SPECIFIED PEN |
| F21 | F21: MODULE TYPE IS NOT PROVIDED FOR REFERENCE CLOCK CIRCUITS |
| F22 | F22: REFERENCE CLOCK CIRCUIT ALREADY EXISTS IN REFERENCE CLOCK TABLE |
| F23 | F23: CIRCUIT IS REFERENCE CLOCK SUPPLIER, CHANGE OF PRIORITY NOT ALLOWED |
| F24 | F24: DELETE NOT POSSIBLE; DELETE FIRST THE CIRCUIT WITH THE CONFIGURATION
AMO (TDCSU, TSCSU) |
| F25 | F25: INSUFFICIENT MEMORY SPACE (AMO DIMSU: PARAMETER LODEN) |
| F26 | F26: PRI MUST BE EQUAL 0 IF PARAMETER SMD = Y FOR THE TRUNK
(S0 TRUNK -> AMO TDCSU: SMD = Y, S2 TRUNK -> AMO LWPAR: SMD = Y) |
| F27 | F27: THE TRUNK IS CAMP-ON BLOCKED. REPEAT COMMAND LATER OR
DEACTIVATE IMMEDIATELY (AMO DSSU) |
| F28 | F28: DELETE NOT POSSIBLE SINCE THERE IS AT LEAST 1 CIRCUIT CONFIGURED
ON THE DIUC MODULE.
INTERROGATE AND DELETE CIRCUIT(S) WITH AMO TACSU |
| F29 | F29: DELETE NOT POSSIBLE SINCE THERE IS AT LEAST 1 CIRCUIT CONFIGURED
ON THE PCM HIGHWAY 2 OF THE DIUC64 MODULE.
INTERROGATE AND DELETE CIRCUIT(S) WITH AMO TACSU |
| F29 | F29: DELETE NOT POSSIBLE SINCE THERE IS AT LEAST 1 CIRCUIT CONFIGURED
ON THE PCM HIGHWAY 1 OF THE DIUC64 MODULE.
INTERROGATE AND DELETE CIRCUIT(S) WITH AMO TACSU |
| F30 | F30: LTUC CIRCUITS WHICH ARE USED AS REFERENCE CLOCK CIRCUITS OF
AN RMS CAN ONLY BE CHANGED WITH AMO REFTA.
AMO REFTA CANNOT DELETE OR CREATE THEM. |
| F31 | F31: BOARDS LOCATED ON AN RMS CANNOT BE ENTERED IN THE REFERENCE CLOCK TABLE |
| F32 | F32: SLMN/DIU-N2/DIU-N4 MODULE; PERMISSIBLE RANGE FOR CIRCUIT NO.: 0 - @@ |
| F33 | F33: DIUS7 MODULE; PERMISSIBLE RANGE FOR CIRCUIT NO.: 0 - @@ |
| F34 | F34: STMA MODULE; PERMISSIBLE RANGE FOR CIRCUIT NO.: 0 - @@ |
| F35 | F35: STMA CIRCUITS CAN ONLY BE CHANGED WITH AMO REFTA.
AMO REFTA CANNOT ADD OR DELETE THEM. (AMO BCSU) |
| F36 | F36: AECB; PERMISSIBLE VALUES FOR CLASS: 38, 68 AND 78 |
| F37 | F37: FRONT REFERENCE EXISTS ALREADY IN THE REFERENCE CLOCK TABLE |
| F38 | F38: EXTERNAL CLOCK BOX EXISTS ALREADY IN THE REFERENCE CLOCK TABLE |
| F39 | F39: EXTERNAL CLOCK BOX NOT CONFIGURED |
| F40 | F40: FRONT REFERENCE NOT CONFIGURED |
| F41 | F41: FRONT REFERENCE IS REFERENCE CLOCK SUPPLIER; BLOCK FIRST |
| F42 | F42: The LTU of the given PEN has the type FLEX.
No ADD-REFTA is possible for such LTUs. |
| F43 | F43: LTU @@ HAS NOT BEEN CONFIGURED |
| F44 | F44: NO MODULE CONFIGURED AT PEN @@-@@-@@@-@@. |
| F45 | F45: The LTU @@ of the given AP-shelf is not of the type NCUI4 or Softgate. |
| F46 | F46: AP REFERENCE IS REFERENCE CLOCK SUPPLIER; BLOCK FIRST |
| F47 | F47: IT IS NOT ALLOWED TO CONFIGURE REFTA ENTRIES FOR SUBSCRIBER CIRCUITS. |
| F48 | F48: IF SMD=Y AND MASTER=Y ARE USED THE PRIORITY MUST BE 0. |
| F49 | F49: NOT COMPLETED. ONLY 176 CIRCUITS WITH PRI>0 ARE ALLOWED. |