The FWD COUNTER in AMO ZAND is used to configure the maximum number
of call forwardings.
- Activate the feature
CHA-FEASU:TYPE=A,CM=HTNW;
- Configure a hunting group with call forwarding
ADD-SA:TYPE=VCE,CD=<hunting group station
number>,STNO=<station numbers of hunting group
station>,STYPE=<(LIN or CYC)>,LVAFTEXT=Y,EXECCFW=Y;
- Configure a hunting group in which call diversion is not allowed, but
in which network-wide stations in the hunting group can be reached
ADD-SA:TYPE=VCE,CD=<hunting group station
number>,STNO=<station numbers of hunting group
stations>,STYPE=<(LIN or CYC)>,EXECCFW=Y;LVAFTEXT=N,
- Configure the maximum number of call forwardings
CHA-ZAND:TYPE=ALLDATA2,FWDMAX=<number of call forwardings>;
- Configure call forwarding
ADD-ZIEL:TYPE=FWD,SRCNO=<forwarding
party>,SI=VOICE,DESTNOF=forwarding destination;
- Activate call forwarding
ADD-ACTDA:TYPE=STN,STNO=<forwarding
party>,FEATCD=FWD,SIFWD=VOICE;
The number of a hunting group's overflow destinations
has been increased. Now an internal VMS (in the local PABX), a network-wide
VMS, a PhoneMail server, and a station number (optionally in the local
PABX, in a network PABX, or in the CO) is allowed. Overflow to the servers
is performed whether or not the FWD COUNTER in AMO ZAND is reached. The
FWD COUNTER limits the overflow to the station number.
- Configure a hunting group with overflow
ADD-SA:TYPE=VCE,CD=<hunting group station
number>,STNO=<station numbers of hunting group
stations>,STYPE=<(LIN or CYC)>,OVFLDEST=<(PHONMAIL,VMSNW,
DESTEXT,NONE)>,NUMBER=<station number>;
The overflow destination can be reached after a call has
spent a cycle in the hunting group. The OVFLCYCL parameter is set to
Y for this.
- Configure a hunting group with overflow and overflow after one cycle
ADD-SA:TYPE=VCE,CD=<hunting group station
number>,STNO=<station numbers of hunting group
stations>,STYPE=<(LIN or
CYC)>,OVFLCYCL=Y,OVFLDEST=<(PHONMAIL,VMSNW,VMSINT,DESTEXT,NON
E)>,NUMBER=<station number>;
Configure a pool for detecting free or busy stations
ADD-DIMSU:TYPE=USER,HGMEMB=<number of configured hunting group
stations>;
If the LVAFTEXT parameter in the AMO SA is set to N, you
must also configure a pool in all systems that feature a network-wide
hunting group station.