27.4.2
Advisories
Sample advisories which are output after an ADD, DELETE or CHANGE has been performed:
H01:
BD aa.bb. ccc ddddddd eeeeeee (fffffff ggggggg)
aa : LTG (1 (HiPath4000)
bb : LTU (1 to 99 (HiPath4000)
ccc : SLOT (1 to 121)
ddddddd : ASSIGNED
NOT ASSIGNED
DELETED
NOT DELETED
CHANGED
NOT CHANGED
eeeeeee : if dddddd = ASSIGNED OR CHANGED:
- IN SERVICE
- OUT OF SERVICE
fffffff : possible additional information
if dddddd = NOT ASSIGNED
ORDER ERROR:order error with assing
MAX. MOD. TYPES: max. no. of mod. types already assigned
if dddddd = NOT CHANGED
NOT BLOCKED: Error with blocking of the module
MAX. MOD. TYPES: max. no. of mod. types already assigned
- INCREASE PERMDL IN AMO DIMSU
- NO FREE LINES IN LTG
fffffff : if eeeeee = OUT OF SERVICE:
Combinations of up to 3 states and a load error can be
output.
DEFModule defective
NPRModule not present
UAModule blocked because of interrelationships
UHModule hierarchically blocked
WBTIncorrect module inserted
ORDER ERROR:Order error with activation following change
LOADERROR: Load error
ggggggg : if fffffff with LOADERROR:
HARDWARE load error: Error in module hardware
FILE load error: no load files for this code
TRANSFER load error: error with data transmission
If an LTU is not assigned within a certain LTU range, the following message is output:
H02:
LTU aa.bb IS NOT ASSIGNED
aa : LTG (1 (HiPath4000)
bb : LTU (1 to 99 (HiPath4000)
H03:
LTG aa IS NOT ASSIGNED
aa : LTG (1 (HiPath4000)
When CHANGE is performed, if there is difference in the number of line circuits for the old and new module, the following message is output:
H04:
NUMBER OF LINE CIRCUITS CHANGED - CHECK LINE CIRCUIT CONFIGURATION
If no corresponding module is found when the module modes are interrogated, the following message is output:
H05:
NO MODULE WITH MODES WAS FOUND WITHIN THE PROCESSED ADDRESS RANGE
H06:
PARAMETER LWVAR WILL BE IGNORED, SIMILAR MODULE TYPE ALREADY ASSIGNED.
VARIANT CAN BE CHANGED USING AMO ZAND.
H07:
FOR THE SLMA1, THE PARAMETERS FOR SOME OF THE TIMERS FOR THE TERMINALS
MUST BE SET WITH THE AMO-SCSU, PARAMETER=CCTIDX (SEE AMO-PTIME, TYPE=SLMA1)
ATTENTION: IF DEVICES ARE CONFIGURED WITH DIALING TYPE = VARIABLE ON THE
add on
SLMA1, THE SLMA BOARD WILL NOT GO IN SERVICE (TYPE VARIABLE NOT
ALLOWED FOR SLMA).
H08:
PARAMETERS FIDX1/2 AND LWPAR1/2 ONLY APPLY TO DIUC, THE INPUT WILL BE IGNORED
H09:
PARAMETER TSI WILL BE IGNORED FOR THE CORRESPONDING
MODULE TYPE
H10:
PARAMETER DEVTYPE WILL BE IGNORED FOR THE CORRESPONDING
MODULE TYPE
H11:
PARAMETER FCTID IS ONLY ALLOWED FOR SIUX BOARDS
PARAMETER FCTID IGNORED
H12:
!!! ATTENTION !!!
CONNECTION BRIDGES ON BACK PLAN WIRING MUST BE SWITCHED AS
DESCRIBED IN SERVICE MANUAL TO PREVENT DESTRUCTION OF RG !!
H13:
FOR SPECIFIED RG (US-RG) ONLY OPMODE UN20H85V VALID
INPUT HAS BEEN CORRECTED BY AMO
H14:
- IF THE SIUP WAS ADDED IN THE HHS, A HARDRESTART IS NECESSARY, TO GET
THE BOARD IN SERVICE
- IF THE SIUP WAS ADDED IN THE AP, A RESTART OF THE AP LTU IS NECESSARY
(AMO USSU).
NUMBER OF POSSIBLE SIUP-BOARDS: ONE PER LTU QUARTER
H15:
THE PARAMETER CIRCNT IS NOT ALLOWED FOR THIS BOARD
THE INPUT WILL BE IGNORED
H16:
FOR SPECIFIED BOARD ONLY TSI=1 IS ALLOWED TO BE SIGNED OFF OR
RELEASED. TSI GREATER THAN 1 WILL BE IGNORED.
H17:
FOR SPECIFIED BOARD THE CIRCUIT 0 HAS TO BE CONFIGURED
(AMO-SSCSU: OPT=TC, DVCFIG=TCLOG)
H18:
FLEX LICENSE EXCEEDED.
SIGNED OFF TSIS ARE MARKED AS TRIAL ENTITY.
THEY WILL BE BLOCKED, IF TRIAL MODE EXPIRES WITHOUT SUFFICIENT LICENSES.
H19:
FOR SPECIFIED BOARD IT IS NOT ALLOWED TO CONFIGURE
FLOW CONTROL VALUES
THE AMO IGNORES THE INPUT
H20:
LTU @@ IS AN OVERLAY LTU FOR LTU @@
H21:
THE ALREADY SIGNED OFF TSI(S) WAS (WERE) NOT REPROCESSED.
IF YOU DID NOT ENTER A VALUE FOR PARAMETER TSI, DEFAULT VALUE TSI = 1
WAS USED.
H22:
PARAMETER LWPAR WILL BE IGNORED FOR TMD/DIU2U BOARDS IN MOS MODE
H23:
YOU DID NOT ENTER A VALID IP ADDRESS.
IP-ADDRESS aaa-bbb-ccc-ddd WAS AUTOMATICALLY RESERVED.
H24:
PARAMETER OPS IS ONLY RELEVANT FOR CIRCUITS ON SLMA BOARDS.
BOARD IS NO SLMA, PARAMETER WILL BE IGNORED.
H25:
THE DEVICETYPE OF A SIGNED OFF TSI ON A SLMQ3 BOARD CAN ONLY BE OPTISET
(PARAMETER DEVTYPE). YOUR INPUT WAS CORRECTED TO DEVTYPE=OPTISET.
H26:
NO DATA CONFIGURED FOR ENTERED PARAMETER VALUES OR DEFAULT VALUES.
H27:
IP-ADDRESS @@@.@@@.@@@.@@@ WAS CONFIGURED.
H28:
PARAMETER FIDX WILL BE IGNORED FOR TMD/DIU2U BOARDS IN MOS MODE
H29:
ENTERED BOARD IS A MIXED LINE CARD (WITH SLMO AND STMD CIRCUITS).
PARAMETER DEVTYPE IS MANDATORY FOR THIS BOARD, BUT WILL BE EVALUATED ONLY
FOR SLMO CIRCUITS.
FOR STMD CIRCUITS, THE ENTERED DEVTYPE WILL BE IGNORED AND THE CIRCUIT
WILL BE SIGNED OFF
H30:
THE (POSSIBLY) ALREADY RELEASED TSI(S) WAS (WERE) NOT REPROCESSED.
H31:
THE AMOUNT OF AVAILABLE B-CHANNELS ON CGW BOARD HAS BEEN CHANGED !
PLEASE CHECK THE RESOURCE MANAGER CONFIGURATION (ALSO AMO-CGWB)
H32:
IF THE PARAMETER BCHLCNT IS SPECIFIED, THE AMOUNT OF AVAILABLE B-CHANNELS
ON CGW BOARD IS SMALLER AS THE DEFAULT VALUE OF THE BOARD !
THE RESOURCE MANAGEMENT IS ALSO AFFECTED BY SPECIFIYING THIS
PARAMETER, THEREFORE ONLY ^anzbkan^ B-CHANNELS WILL BE CONFIGURED.
H33:
THE FLAG TO FORCE BOARD LOADING IS SET.
IF YOU WANT TO PREVENT REPEATEDLY BOARD LOADING PROCESSES; THE FLAG
SHOULD BE RESET AFTER THE FIRST LOADING OF THE BOARD BY MEANS OF :
CHANGE-FUNSU:FLASH,,,RESET;
H34:
DUE TO ACTIVATED FEATURE SIGNALLING & PAYLOAD ENCRYPTION AND/OR ACTIVATED
DMC THE NUMBER OF CONFIGURED B-CHANNELS FOR <function> HAVE BEEN REDUCED BY @@@ B-CHANNELS.
ACTUAL AVAILABLE <function> B-CHANNELS: @@@
H35:
THE PROCESSED CHANGES HAVE NEEDED A DEACTIVATED STMI BOARD.
THE BOARD IS INITIATED TO BE TAKEN IN SERVICE AGAIN RIGHT NOW.
H36:
THE SETTING OF PARAMETER BITRATE HAS BEEN CHANGED TO 100MBFD
BECAUSE OF HW RELATED RESTRICTIONS. CHANGE POSSIBLE WITH AMO-CGWB.
H37:
NO (FURTHER) RESERVED LINES AVAILABLE, PARAMETER CHNGRSLN IGNORED.
H38:
LESS RESERVED LINES ARE AVAILABLE AS SPECIFIED VIA PARAMETER CHNGRSLN.
THE MAXIMUM POSSIBLE CONFIGURATION WILL BE APPLIED.
H39:
THE PARAMETERS FOR CHANGING THE NUMBER OF B-CHANNELS WILL BE IGNORED IF
THE ACCORDING FUNCTION IS NOT CONFIGURED.
H40:
THE DESIRED CONFIGURATION HAS TO BE CUT BECAUSE IN TOTAL THE CONFIGURED VIRTUAL GATEWAYS NEED MORE PORTS THAN THE ACTUAL SOFTGATE TYPE ALLOWS.
H41:
FOR SUBSCRIBER CONFIGURATIONS ON THIS BOARD, NO ENTRIES ARE VALID IN THE REFERENCE CLOCK TABLE. FURTHERMORE LEAD REFERENCE CLOCK ENTRIES WHICH ARE NOT FOLLOWED BY TRUNK CONFIGURATIONS TO HEAVY SYSTEM MALFUNCTIONS.
H42:
UBGDAT ENTRY HAS BEEN MODIFIED INTERNALLY BEFORE FIRST USAGE.
H43:
BOARD DATA HAVE TO BE CONFIGURED WITH AMO CGWB.
H44:
DHCP IS ACTIVATED. LEGK CONFIGURATIONS (AMO-GKREG) ARE SUSPENDED FOR THIS GATEWAY.
H45:
FOR IPMODE SET TO DUAL STACK OR IPV6 MODE, A PROFILE FOR SIPQ TRUNKS HAS TO BE CONFIGURED VIA WBM.
H46:
THE PARAMETERS IPMODE, DHCPV4 UND DHCPV6 ARE NOT RELEVANT FOR TRADITIONAL HG3500 BOARDS AND WILL BE IGNORED.
H47:
DHCP IS ACTIVATED BUT AT LEAST ONE CONFIGURED IP ADDRESS IS NOT VALID ! THE GATEWAY CANNOT BE TAKEN INTO SERVICE.
H48:
Please note that DHCP functionality is not fully supported yet (in Release 0).
H49:
TO COMPLETE THE DELETION OF BOARD RELATED DATA, A MANUAL RESTART OF THE SOFTGATE IS NEEDED: RES-USSU:RESTYPE=LTU,LTU=<LTU>;
H50:
PARAMETER LWVAR WILL BE IGNORED, FOR SLC24 BOARDS ONLY LWVAR 7 IS VALID.
H51:
CLASSICAL BOARD IS CONVERTED TO VIRTUAL, AS THE LTU IS A SOFTGATE.
H52:
PARAMETER LWVAR WILL BE IGNORED, FOR SLMC BOARDS ONLY LWVAR 4 IS VALID.
H53:
G723 IS NOT SUPPORTED BY STMIX BOARD. IT HAS TO BE DEACTIVATED BY MEANS OF AMO CGWB: CHA-CGWB:MTYPE=CGW,LTU=<xx>,SLOT=<xxx>,TYPE=ASC,PRIO=PRIO<xxx>,CODEC=NO
H54:
G723 HAS BEEN DECTIVATED ON STMIX BOARD. IF NEEDED IT CAN BE ACTIVATED FOR THE NEW BOARD BY MEANS OF AMO CGWB.
H55:
THE BOARD FROM PEN @@-@@-@@@ WILL BE ACTIVATED