GEFE - Call Charge Recording On Terminating a Connection

The function of the AMO is to administer general parameters for call charge recording and the call charge recording parameters for specific countries.

Add node id modification KNMATxxx:

Add parameter CHRGPLS:

Note:

  • The parameter CHRGPLS (call charge recording at the end of a connection) must be set to 'Y' (Yes) if the central office at which the Hicom is connected transmits all the charge pulses back to the Hicom when a connection is terminated.

  • In all other cases, the parameter CHRGPLS (call charge recording at the end of a connection) must be set to 'N' (No).

  • If the parameter CHRGPLS (call charge recording at the end of a connection) is set to 'Y' (Yes) in these cases, the trunk call is always charged to the station which set up the call. This is independent of how many times the trunk call was transfered later.

  • For a complete description of the parameters see 'CHANGE-GEFE'.

    Cross Reference to Other AMOs:

    AMO-COSSU :Classes of Service
    AMO-DEFPP :Define Paying Party
    AMO-FEASU :AMO-FEASU: Features (Bit String) in the SWU
    AMO-KNMAT :Administer Node Connection Matrix
    AMO-LDAT :LDAT Configuration of Routes
    AMO-TTBL :TTBL SMDR/DMDR tariff table

    Destination Processor: ADP

    Functions

    CHANGE Changing the parameters for call charge registration. password class 2
    DISPLAY Displaying the parameters password class 0
    REGENERATE Regenerating the parameters password class 2
    DELETE Deleting the entry for numbermodification(NMOD) password class 2

    Procedure Overview

    CHANGE-GEFE

    CHANGE-GEFE
    TYPPARAM=CAR,CARRIER=<number>, {(min 1) TYPE=<param>, CHRGPLS=<param>};
    TYPPARAM=DN,DNSHORT=<param>;
    TYPPARAM=SAMEPP,TICKET=<param>;
    TYPPARAM=REALUNIT,REALUNIT=<param>;
    TYPPARAM=CCALLDIR,CCALLDIR=<param>;
    TYPPARAM=RNGDT,RNGDT=<param>;
    TYPPARAM=QUEUEDUR,QUEUEDUR=<param>;
    TYPPARAM=SRSUBS,SRSUBS=<param>;
    TYPPARAM=ATTNDOUT,ATTNDOUT=<param>;
    TYPPARAM=ATTNDINC,ATTNDINC=<param>;
    TYPPARAM=INCOLD,INCOLD=<param>;
    TYPPARAM=CONFAOCS,
    CONFAOCS=THRCONN,THRCONN=<param>;
    CONFAOCS=NTHRCONN,NTHRCONN=<param>;
    TYPPARAM=METHOD,CARRIER=<number>, {(min 1) MNORM=<number>, MSCRSPC=<number>, MPUPHON=<number>, MMTEQ=<number>};
    TYPPARAM=PREINC,PARTY=<param>;
    TYPPARAM=PREINT,PARTY=<param>;
    TYPPARAM=PREOUT,PARTY=<param>;
    TYPPARAM=KNMATINC,PARTY=<param>;
    TYPPARAM=KNMATINT,PARTY=<param>;
    TYPPARAM=KNMATOUT,PARTY=<param>;
    TYPPARAM=FILLLIST,INTNLIST=<param>;
    TYPPARAM=SLCALLED,SLCALLED=<param>;
    TYPPARAM=NMOD,NODENO=<number>, {(min 1) DADD=<key-num>, DREM=<key-num>}, DMIN=<number>, [PTY=<param>];

    Changing the parameters for call charge registration.

    Parameter TYPPARAM indicates the type of subsequent values.

    1. Branch DN:

      The parameter DNSHORT (destination number shortened by 2 digits) in the branch DN indicates whether the destination number is to be shortened by 2 digits. If the parameter DNSHORT is set to 'Y' (Yes), the destination number is shortened by the last 2 digits. If the parameter DNSHORT is set to 'N' (No), the destination number is completely entered. In this case the destination number is called party, connected party (new / through connected) and redirection party.
      The default value of the parameter DNSHORT is set to 'N' (No).
    2. Branch ATTNDINC:

      The parameter ATTNDINC in the branch ATTNDINC indicates whether with an incoming connection the attendant / secretary can be made liable to pay his own costs or not.
      If the attendant is not liable to pay the costs, then the accumulated charges pays the transferring party.
      If the secretary is not liable to pay the costs, then the accumulated charges pays the transferring chief.
      The default value of the parameter ATTNDINC is set to 'N' (No).
      The feature CDR-E (switch in AMO-FEASU) overrules the switches ATTNDINC and ATTNDOUT. These values now are set to 'Y' (Yes).

      Note: With an internal connection there is no distinction between attendant / secretary and normal user. All users are directly treated therefore and no costs are transferred.

    3. Branch ATTNDOUT:

      The parameter ATTNDOUT in the branch ATTNDOUT indicates whether with an outgoing connection the attendant / secretary can be made liable to pay his own costs or not.
      If the attendant is not liable to pay the costs, then the accumulated charges pays the transferring party.
      If the secretary is not liable to pay the costs, then the accumulated charges pays the transferring chief.
      The default value of the parameter ATTNDOUT is set to 'N' (No).

      Note: With an internal connection there is no distinction between attendant / secretary and normal user. All users are directly treated therefore and no costs are transferred.

    4. Branch INCOLD:

      The parameter INCOLD in the branch INCOLD indicates the output of the incoming calling in the field of calling. This parameter is a reproduction of functionality from E V2.0.
      The default value of the parameter INCALT is set to 'N' (No).

    5. Branch CONFAOCS:

      The parameter CONFAOCS (configuration of call charging over AOC_S (advice of charges - set-up) messages) indicates whether the cost calculation begins before or after through connected.
      If parameter THRCONN is set to CALLATT , the cost calculation begins before through connected (call charges are also calculated for call setup attempt).
      The branch CONFAOCS has two parameters THRCONN (through connected) and NTHRCONN (non through connected). Both branches consist of five (BASCOMM, CALLATT, CSETUP, OPOFSS and UUI or NBASCOMM, NCALLATT, NCSETUP, NOPOFSS and NUUI) elements. The parameters OPOFSS and UUI or NOPOFSS and NUUI are currently not used.
      The detailed description of parameters see Parameter Description.
      It must be set at least one attribute of the parameter THRCONN or NTHRCONN.

    6. Branch KNMATINT:

      The branch KNMATINT is the branch for the node id modification for internal traffic. The parameter PARTY indicates the stations, which are to be modified (AMO-KNMAT).

    7. Branch KNMATINC:

      The branch KNMATINC is the branch for the node id modification for incoming traffic. The parameter PARTY indicates the stations, which are to be modified (AMO-KNMAT).

    8. Branch KNMATOUT:

      The branch KNMATOUT is the branch for the node id modification for outgoing traffic. The parameter PARTY indicates the stations, which are to be modified (AMO-KNMAT).

    9. Branch PREINT:

      The branch PREINT is the branch for the node id modification for internal traffic. The parameter PARTY indicates the stations, which are to be modified.
      The value CALLEPTY of the parameter PARTY may be used only in connection with the branch PREINT.

    10. Branch PREINC:

      The branch PREINC is the branch for the node id modification for incoming traffic. The parameter PARTY indicates the stations, which are to be modified.
      The value CALLEPTY of the parameter PARTY may be used only in connection with the branch PREINC.

    11. Branch PREOUT:

      The branch PREOUT is the branch for the node id modification for outgoing traffic. The parameter PARTY indicates the stations, which are to be modified.
      The value CALLEPTY of the parameter PARTY may be used only in connection with the branch PREOUT.

    12. Branch CAR:

      Changing of parameter CHRGPLS (call charge recording at the end of a connection) in the branch CAR. Setting of parameter CHRGPLS to 'Y' (Yes) means call charge information at the end of a connection or resetting of parameter CHRGPLS to 'N' (No) means no call charge information at the end of a connection. The parameter CHRGPLS must be created per CARRIER.
      Changing of parameter TYPE (type of call charge recording) in the branch CAR. This parameter indicates whether by a carrier charge information are transmitted (TYPE=PULSE) or are not transmitted (TYPE=TIME), or both is mixed (TYPE=MIX) used. This parameter TYPE is needed by the component charge calculation (CHCALC) of the charging, in order to calculate the charges by rate units, or on the basis of connection time.
      The parameters CARRIER (number of carrier of a connection, AMO-LDAT), TYPE (type of call charge recording) and CHRGPLS (call charge recording at the end of a connection) form a min-1-group.
      The parameter CARRIER must be entered and additional at least one of the flags TYPE and CHRGPLS.
      If the parameter CARRIER is not entered, the advisory message H01 is issued to the user.

    13. Branch METHOD:

      The branch METHOD is only used for feature Rural (pulse metering & sending, SLMAR-station).
      There are three methods for charging:

      1. Method 0: The received charge pulses from carrier are forwarded unchanged to the SLMAR-module.

      2. Method 1 : Only the first charge pulse received from carrier is suppressed. All further pulses (units from CENTRAL OFFICE) are passed through.

      3. Method 2: The first charge pulse is passed through. The second charge pulse received from carrier is suppressed. All further pulses are passed through.

      The parameter CARRIER and at least one of the parameter group MNORM, MSCRSPC, MPUPHON, MMTEQ must be entered (min-1-group).

    14. Branch REALUNIT:

      The branch REALUNIT (units from CENTRAL OFFICE) indicates, that the charge units received from carrier, to be output into the data record, although the call is charged after time. In this case the parameter TYPE is set to 'TIME'.

    15. Branch SAMEPP:

      The parameter TICKET in the branch SAMEPP indicates whether with same paying party with the call transfer a ticket should be created or not.
      The default value of the parameter TICKET is set to 'Y' (Yes).

      Example:

    16. Branch CCALLDIR:

      The branch CCALLDIR allows a change of the call direction in the ticket sequenz.
      The default value of the parameter CCALLDIR is set to 'N' (No).

    17. Branch RNGDT:

      The branch RNGDT displays the new ringing of through connected call in ticket filled in field RING_DUR. In this case the same value is filled in in field CONN_DUR.
      The default value of the parameter RNGDT is set to 'N' (No).

      Note: In ticket in field SUPLSERV displays 'RING_AF_CON'.

    18. Branch QUEUEDUR:

      The branch QUEUEDUR permits the output of QUEUE_DUR without activation of feature CDRE.
      The default value of the parameter QUEUEDUR is set to 'N' (No).

    19. Branch SRSUBS:

      The branch SRSUBS displays a subscriber with attribute restricted in field CHRGEE.
      The default value of the parameter SRSUBS is set to 'Y' (Yes).

    20. Branch FILLLIST:

      The branch FILLLIST controles the list entries for INTNLIST. The parameter INTNLIST (Y/N) indicates, if a list entry has to be done if no valid line number is available.
      The default value of the parameter is set to 'N' (No).

    21. Branch SLCALLED:

      The branch SLCALLED controles based on which party (called or destination party) the selection in the destination list has to be done. The parameter SLCALLED (Y/N) indicates, that for selection the called party has to be used.
      The default value of the parameter is set to 'N' (No).

    22. Branch NMOD:

      The branch NMOD is used for station number modification of a entered node.

    Examples:

    1. Changing the parameters:

      No destination number shortening; attendant / secretary for incoming connection must pay his own costs; no output of the incoming calling in the field of calling; through connected calls: basic call charge (BASCOMM) and cost calculation for call setup (CSETUP); not through connected calls: basic call charge (NBASCOMM) and call charge for call setup attempt (NCALLATT); node id modification for internal traffic: calling party and redirecting party; node id modification for incoming traffic: calling party, key line used and mobile user calling; node id modification for outgoing traffic: calling party; prefixhandling for internal traffic: calling party and mobile user calling; prefixhandling for incoming traffic: called party and key line used; prefixhandling for outgoing traffic: redirecting party and mobile user calling; call charge recording with charge information from CENTRAL OFFICE for carrier 1 and no charge pulse at the end of a connection; method 0 for 'normal' station (see AMO-COSSU: Normal pulse metering & sending stations are stations, where the parameters AVCE=PUPHON, AVCE=SCRSPC or AVCE=MTEC are not set.) and method 1 for station with 'special charging' (see AMO-COSSU: pulse metering & sending, parameter AVCE=SCRSPC is set; charge information from CENTRAL OFFICE is saved in call charge data record; no extra ticket, if the paying party stays the same; allows a change of the call direction in the ticket sequenz; no display of the new ringing of through connected call, in ticket filled in in field RING_DUR; output of QUEUE_DUR without activation of feature CDRE; Display of a subscriber with attribute restricted in field CHRGEE.
      DNSHORT=N;
      ATTNDINC=Y;
      INCOLD=N;
      THRCONN=BASCOMM&CSETUP;
      NTHRCONN=NBASCOMM&NCALLATT;
      PARTY=CALLIPTY&RTINGPTY;
      PARTY=CALLIPTY&KEYPTY&MOBUCPTY;
      PARTY=CALLIPTY;
      PARTY=CALLIPTY&MOBUCPTY;
      PARTY=CALLEPTY&KEYPTY;
      PARTY=RTINGPTY&MOBUCPTY;
      CARRIER=1,TYPE=PULSE,CHRGPLS=N;
      CARRIER=1,MNORM=0,MSCRSPC=1;
      REALUNIT=Y;
      TICKET=N;
      CCALLDIR=Y;
      RNGDT=N;
      QUEUEDUR=Y;
      SRSUBS=Y;

    2. Input:
       CHANGE-GEFE:TYPPARAM=DN,DNSHORT=N;
      CHANGE-GEFE:TYPPARAM=ATTNDINC,ATTNDINC=Y;
      CHANGE-GEFE:TYPPARAM=INCOLD,INCOLD=N;
      CHANGE-GEFE:TYPPARAM=CONFAOCS,CONFAOCS=THRCONN,THRCONN=BASCOMM&CSETUP;
      CHANGE-GEFE:TYPPARAM=CONFAOCS,CONFAOCS=NTHRCONN,NTHRCONN=NBASCOMM&NCALLATT;
      CHANGE-GEFE:TYPPARAM=KNMATINT,PARTY=CALLIPTY&RTINGPTY;
      CHANGE-GEFE:TYPPARAM=KNMATINC,PARTY=CALLIPTY&KEYPTY&MOBUCPTY;
      CHANGE-GEFE:TYPPARAM=KNMATOUT,PARTY=CALLIPTY;
      CHANGE-GEFE:TYPPARAM=PREINT,PARTY=CALLIPTY&MOBUCPTY;
      CHANGE-GEFE:TYPPARAM=PREINC,PARTY=CALLEPTY&KEYPTY;
      CHANGE-GEFE:TYPPARAM=PREOUT,PARTY=RTINGPTY&MOBUCPTY;
      CHANGE-GEFE:TYPPARAM=CAR,CARRIER=1,TYPE=PULSE,CHRGPLS=N;
      CHANGE-GEFE:TYPPARAM=METHOD,CARRIER=1,MNORM=0,MSCRSPC=1;
      CHANGE-GEFE:TYPPARAM=REALUNIT,REALUNIT=Y;
      CHANGE-GEFE:TYPPARAM=SAMEPP,TICKET=N;
      CHANGE-GEFE:TYPPARAM=CCALLDIR,CCALLDIR=Y;
      CHANGE-GEFE:TYPPARAM=RNGDT,RNGDT=N;
      CHANGE-GEFE:TYPPARAM=QUEUEDUR,QUEUEDUR=Y;
      CHANGE-GEFE:TYPPARAM=SRSUBS,SRSUBS=Y;
      CHANGE-GEFE:TYPPARAM=FILLLIST,INTNLIST=N;
      CHANGE-GEFE:TYPPARAM=SLCALLED,SLCALLED=N;
      CHANGE-GEFE:TYPPARAM=NMOD,NODENO=0-0-100,DREM=2,DMIN=3,PTY=PAYING;

    DISPLAY-GEFE

    DISPLAY-GEFE ;

    1. Interrogating the parameter values with output values in suitable form for printing. All flags are output.

    2. Interrogating the parameter values with output in position-oriented commands for regeneration.

    Examples:

    1. Interrogating (displaying) the parameters

    2. Input:
      DISPLAY-GEFE;

      Output:
            COSTDUTY OF ATTENDANT / SECRETARY   INCOMING  : YES 
      OUTGOING : NO


      CHANGE OF CALL DIRECTION IN TICKET SEQUENZ : YES
      NEW RINGING, THROUGH CONN. CALL IN RINGDUR : NO
      OUTPUT OF QUEUE_DUR WITHOUT ACTIVATION OF CDRE : YES
      SHOW RESTRICTED SUBSCRIBER IN PAYINGPARTY : YES
      DESTINATION NUMBER SHORTENED BY 2 DIGITS : NO
      TICKET BY SAME PP : NO
      OFFICIAL UNITS ARE SAVED IN CDB : YES
      COMING CALLING IN FIELD CONN PTY;DESTPTY=CALLIPTY : NO


      AOC-S COST CALCULATION CONFIGURATION
      THROUGH CONNECTED
      BASIC COMM : YES
      CALL ATTEMPT : NO
      CALL SETUP : YES
      UUI : NO
      OP. OF. SS. : NO
      NON THROUGH CONNECTED
      BASIC COMM : YES
      CALL ATTEMPT : YES
      CALL SETUP : NO
      UUI : NO
      OP. OF. SS. : NO


      NODE ID HANDLUNG
      INTERNAL :
      CALLING PARTY
      REDIRECTING PARTY
      INCOMING :
      CALLING PARTY
      MOBILE USER CALLING
      KEY LINE USED
      OUTGOING :
      CALLING PARTY
      PREFIX HANDLING OF STATION
      INTERNAL :
      CALLING PARTY
      MOBILE USER CALLING
      INCOMING :
      CALLED PARTY
      KEY LINE USED
      OUTGOING :
      REDIRECTING PARTY
      MOBILE USER CALLING


      CARRIER TYPE OF CALL DATA REG. METHODS FOR
      CDR END CONNECTION NORM SPEC PUBL OPER


      1 PULSE NO 0 1 0 0
      2 MIX NO 0 0 0 0
      3 MIX NO 0 0 0 0
      4 MIX NO 0 0 0 0
      5 MIX NO 0 0 0 0
      6 MIX NO 0 0 0 0
      7 MIX NO 0 0 0 0
      8 MIX NO 0 0 0 0
      9 MIX NO 0 0 0 0


      CARRIER 0 ( FOR INTERNAL CHARGING ) HAS ALWAYS TYPE TIME

    REGENERATE-GEFE

    REGENERATE-GEFE ;

  • Interrogating the parameter values with output in position-oriented commands for regeneration.

    1. Regenerating the parameters

      Input:
      REGEN-GEFE;

      Output:
        CHANGE-GEFE:KNMATINT,CALLIPTY&RTINGPTY;
      CHANGE-GEFE:KNMATOUT,CALLIPTY;
      CHANGE-GEFE:KNMATINC,CALLIPTY&MOBUCPTY&KEYPTY;
      CHANGE-GEFE:PREINT,CALLIPTY&MOBUCPTY;
      CHANGE-GEFE:PREOUT,RTINGPTY&MOBUCPTY;
      CHANGE-GEFE:PREINC,CALLEPTY&KEYPTY;
      CHANGE-GEFE:ATTNDOUT,N;
      CHANGE-GEFE:ATTNDINC,Y;
      CHANGE-GEFE:CCALLDIR,Y;
      CHANGE-GEFE:RNGDT,N;
      CHANGE-GEFE:QUEUEDUR,Y;
      CHANGE-GEFE:SRSUBS,Y;
      CHANGE-GEFE:DN,N;
      CHANGE-GEFE:SAMEPP,N;
      CHANGE-GEFE:REALUNIT,Y;
      CHANGE-GEFE:INCOLD,N;
      CHANGE-GEFE:CONFAOCS,THRCONN,BASCOMM&CSETUP;
      CHANGE-GEFE:CONFAOCS,NTHRCONN,NBASCOMM&NCALLATT;
      CHANGE-GEFE:CAR,1,PULSE,N;
      CHANGE-GEFE:CAR,2,MIX,N;
      CHANGE-GEFE:CAR,3,MIX,N;
      CHANGE-GEFE:CAR,4,MIX,N;
      CHANGE-GEFE:CAR,5,MIX,N;
      CHANGE-GEFE:CAR,6,MIX,N;
      CHANGE-GEFE:CAR,7,MIX,N;
      CHANGE-GEFE:CAR,8,MIX,N;
      CHANGE-GEFE:CAR,9,MIX,N;
      CHANGE-GEFE:METHOD,1,0,1,0,0;
      CHANGE-GEFE:METHOD,2,0,0,0,0;
      CHANGE-GEFE:METHOD,3,0,0,0,0;
      CHANGE-GEFE:METHOD,4,0,0,0,0;
      CHANGE-GEFE:METHOD,5,0,0,0,0;
      CHANGE-GEFE:METHOD,6,0,0,0,0;
      CHANGE-GEFE:METHOD,7,0,0,0,0;
      CHANGE-GEFE:METHOD,8,0,0,0,0;
      CHANGE-GEFE:METHOD,9,0,0,0,0;

    DELETE-GEFE

    DELETE-GEFE
    TYPPARAM=NMOD,NODENO=<number>, {(min 1) DADD=<key-num>, DREM=<key-num>};

    .

  • Deleting the entry for numbermodification(NMOD) from the file stored in database (delete action is only possible for NMOD branch).

  • Examples:

      Input:
      DEL-GEFE:TYPPARAM=NMOD,NODENO=0-0-100,DREM=2;

      Output:
      H03: ENRTY HAS BEEN DELETED SUCCESFULLY.

    Parameter description

    ATTNDINC inc. attendant /Secr. must pay his own costs
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    ATTNDOUT outg. attendant /Secr. must pay his own costs
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    CARRIER number of carrier of a connection
    Type of Input: single value, mandatory
    Possible Values: numeric, 1-9
    CCALLDIR Allow change of call direction in ticketsequenz
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    CHRGPLS flag for call charge recording at the end of a connection
    Type of Input: single value, 2. parameter of a min-1-group
    Possible Values: N no
    Y yes
    CONFAOCS configuration of the call charging over aoc-s Messages
    Type of Input: single value, mandatory
    Possible Values: NTHRCONN for not through connected calls
    THRCONN for through connected calls
    DADD Digits to add
    Type of Input: single value, 1. parameter of a min-1-group
    Possible Values: 0-9,*,#,A-D, up to 22 characters
    DMIN Minimum of remaining digits
    Type of Input: single value, mandatory
    Possible Values: numeric, 0-22
    Default Value: 6
    DNSHORT destination number shortened by 2 digits
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    DREM Digits to remove
    Type of Input: single value, 2. parameter of a min-1-group
    Possible Values: 0-9,*,#,A-D, up to 22 characters
    INCOLD incoming calling in the field of conn pty;DESTPTY=CALLIPTY
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    INTNLIST List entry if no valid line number available
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    MMTEQ maintenance 0: no change 1,2: 1 or 2 impulse is suppr.
    Type of Input: single value, 4. parameter of a min-1-group
    Possible Values: numeric, 0-2
    MNORM norm sbscr 0: no change 1,2: 1 or 2 impulse is suppr.
    Type of Input: single value, 1. parameter of a min-1-group
    Possible Values: numeric, 0-2
    MPUPHON publ phone 0: no change 1,2: 1 or 2 impulse is suppr.
    Type of Input: single value, 3. parameter of a min-1-group
    Possible Values: numeric, 0-2
    MSCRSPC spec sbscr 0: no change 1,2: 1 or 2 impulse is suppr.
    Type of Input: single value, 2. parameter of a min-1-group
    Possible Values: numeric, 0-2
    NODENO Node number
    Type of Input: 1 to 3 single values, concatenated with -, mandatory
    Possible Values: numeric, 0-1001
    NTHRCONN for not through connected calls
    Type of Input: 1 to 5 single values, concatenated with &, mandatory
    Possible Values: NBASCOMM basic call charge DB_CHRG_ITEM_BASIC_COMM
    NCALLATT basic call charge for call setup attempt DB_CHRG_ITEM_CALL_ATTEMPT
    NCSETUP costs for call setup DB_CHRG_ITEM_CALL_SETUP
    NOPOFSS Operation of supplemenentary services DB_CHRG_ITEM_OP_OF_SS
    NUUI user to user info DB_CHRG_ITEM_UUI
    Default Value: bascomm&csetup
    PARTY Station to be modified.
    Type of Input: 1 to 9 single values, concatenated with &, mandatory
    Possible Values: CALLEPTY called party DA_CGD_PTY_CALLED (CHANGE,TYPPARAM=PREINC-prefixhandling for incoming traffic / CHANGE,TYPPARAM=PREINT-prefixhandling for internal traffic / CHANGE,TYPPARAM=PREOUT-prefixhandling for outgoing traffic)
    CALLIPTY calling party DA_CGD_PTY_CALLING
    CONNPTY new / connected party; DA_CGD_PTY_NEW
    KEYPTY key line used DA_CGD_PTY_KEYCALL
    MOBUCPTY mobile user calling DA_CGD_PTY_MOBILE
    NOPTY No user is modified. DA_CGD_PTY_NO
    PAYPTY Party that pays his own costs. DA_CGD_PTY_PAYING
    RTINGPTY redirecting party; Party that redirects a call. DA_CGD_PTY_REDIRECTING
    RTIONPTY redirection party, where a call is redirected to DA_CGD_PTY_REDIRECTION
    TRNSFPTY transferring_party; party that transferred a call DA_CGD_PTY_TRANSFER
    PTY Party to modify
    Type of Input: 1 to 3 single values, concatenated with &, optional
    Possible Values: CALLING DB_RNMOD_PTY_CALLING
    CONNECT DB_RNMOD_PTY_CONNECTED
    PAYING DB_RNMOD_PTY_PAYING
    Default Value: PAYING
    QUEUEDUR Output of QUEUE_DUR without activation of CDRE
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    REALUNIT official units are saved in cdb
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    RNGDT NEW RINGING, THROUGH CONN. CALL IN RINGDUR
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    SLCALLED Destlist uses called party
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    SRSUBS Show subscriber, with attribute restricted, in PayingParty
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    THRCONN for through connected calls
    Type of Input: 1 to 5 single values, concatenated with &, mandatory
    Possible Values: BASCOMM basic call charge DB_CHRG_ITEM_BASIC_COMM
    CALLATT basic call charge for call setup attempt DB_CHRG_ITEM_CALL_ATTEMPT
    CSETUP costs for call setup DB_CHRG_ITEM_CALL_SETUP
    OPOFSS Operation of supplemenentary services DB_CHRG_ITEM_OP_OF_SS
    UUI user to user info DB_CHRG_ITEM_UUI
    Default Value: bascomm&csetup
    TICKET extra ticket by same paying-party created
    Type of Input: single value, mandatory
    Possible Values: N no
    Y yes
    TYPE method of call charge recording
    Type of Input: single value, 1. parameter of a min-1-group
    Possible Values: MIX mixed call charge recording DA_CG_TOC_MIXED_CHRG
    PULSE call charge recording with call charge information DA_CG_TOC_WITH_UNITS
    TIME call charge recording without call charge info. DA_CG_TOC_WITHOUT_UNITS
    TYPPARAM type of parameters
    Type of Input: single value, mandatory
    Possible Values: ATTNDINC inc. attendant /Secr. must pay his own costs (CHANGE)
    ATTNDOUT outg. attendant /Secr. must pay his own costs (CHANGE)
    CAR indicated parameters for a carrier (CHANGE)
    CCALLDIR Allow change of call direction in ticketsequenz (CHANGE)
    CONFAOCS config. of the call charging over aoc-s Messages (CHANGE)
    DN setting of short destination number (CHANGE)
    FILLLIST List entry for INTNLIST (CHANGE)
    INCOLD Coming calling in field conn pty;DESTPTY=CALLIPTY (CHANGE)
    KNMATINC node id for incoming traffic (CHANGE)
    KNMATINT node id for internal traffic (CHANGE)
    KNMATOUT node id for outgoing traffic (CHANGE)
    METHOD method (CHANGE)
    NMOD Numbermodification
    PREINC prefixhandling for incoming traffic (CHANGE)
    PREINT prefixhandling for internal traffic (CHANGE)
    PREOUT prefixhandling for outgoing traffic (CHANGE)
    QUEUEDUR Output of QUEUE_DUR without activation of CDRE (CHANGE)
    REALUNIT official units are saved in cdb (CHANGE)
    RNGDT NEW RINGING, THROUGH CONN. CALL IN RINGDUR (CHANGE)
    SAMEPP extra ticket by same paying-party created (CHANGE)
    SLCALLED Destlist uses called party (CHANGE)
    SRSUBS Show restricted subscriber in PayingParty (CHANGE)

    Error Messages

    F01
    F01: PARAMETER VALUE NOPTY MUST BE INPUT UNCHAINED ONLY. 
    F02
    F02: THE NODE NUMBER MAY NOT BE 0
    F03
    F03: LEVEL@ OF NODE NUMBER MAY NOT EXCEED VALUE @@@
    F04
    F04: LEVEL1 OF NODE NUMBER MAY NOT BE 0
         IF LEVEL2 AND LEVEL0 ARE NOT 0
         (EXAMPLE: 1-0-1 IS NOT POSSIBLE)
    F06
    F06: The desired entry already exists.
    F07
    F07: It is not possible to add more entries because the table is full.
    F08
    F08: ONLY ONE DADD IS POSSIBLE FOR SAME NODE NUMBER.
    F09
    F09: DREM PATTERN ALREADY DEFINED FOR THIS NODE.
    F10
    F10: ENTRY CANNOT BE DELETED.
    F11
    F11: NO ENTRY FOUND.

    Advisory Messages

    H03
    H03: ENRTY HAS BEEN DELETED SUCCESFULLY.