Only one TDS port may be konfigured in the whole HHS shelf range (1 - 15). This means, that in this whole range only one SIU type 4 can be configured with AMO BCSU. On some system platforms it is furthermore possible, to configure a central SIU (DSCX/SIUCO) with AMO UCSU. In this case a TDS port will be configured by AMO UCSU for this central SIU. If such a DSCX/SIUCO is configured as central SIU, it is not possible to configure a peripheral SIU type 4.
|
|
•
|
In the AP shelf range (17 - 99) one TDS port may be configured per LTU. This Port will be configured by AMO UCSU, when the NCUI board is added. That means: it is not possible, to configured a SIU type 4 in an AP shelf.
|
|
•
|
If certain loadwareparameters are desired for this BOS board, the user has the possibility, to preconfigure a loadware block with AMO LWPAR as desired, and enter the number of this configured loadware block during the board configuration (ADD-BCSU: parameter = LWPAR ). If no value is entered for parameter LWPAR, a default loadware block will be assigned.
|
|
•
|
|
•
|