10.4.1
Error Messages
F01:
THE INPUT FOR PARAMETER 'AGTID'
MUST BE EXACTLY @ DIGITS LONG.
(DISP-
ACDSD
:TYPE=SYS; PARAMETER 'AGTIDLEN').
F02:
AGENT IDENTIFICATION NUMBER
AGTID=@@@@@@ IS ALREADY IN USE.
F03:
NO ACD GROUP WITH ACDGRP=@@@ CONFIGURED.
(DISP-
ACDGP
:ACDGRP;)
F04:
NO MORE AGENTS CAN BE ASSIGNED TO ACD GROUP ACDGRP=@@@.
THE MAXIMUM NUMBER OF AGENTS HAS ALREADY BEEN ATTAINED.
F05:
INSTEAD OF AUTOWK=@@@@ ENTER ANY VALUE BETWEEN 1 TO 9, OR A MULTIPLE OF 5
BETWEEN 10 TO 300 FOR THE LENGTH OF THE SYSTEM CONTROLLED WORK PERIOD.
F06:
THE SUBSCRIBER CAN NOT BE CONFIGURED AS AN AGENT HAVING
'AUTOMATIC LOGON' FEATURE (AUTOEXT=@@@@@@) BECAUSE THE
STATION NUMBER HAS BEEN CONFIGURED AS A FLOATING STATION.
(SEE AMO
SCSU
, INS=FLOAT)
F08:
STATION NUMBER AUTOEXT=@@@@@@ MUST FIRST BE
CLASSMARKED FOR THE AUTOMATIC LOGON FEATURE.
SET REQUESTED CLASSMARK WITH THE FOLLOWING COMMAND:
CHANGE-
SDAT
:STNO=@@@@@@,TYPE=ATTRIBUT,AATTR=AUTOLOG;
F09:
FOR A FLEXIBLE AGENT THE OPTIONAL PARAMETERS
'AGTPOS' AND 'AUTOEXT' MAY NOT BE SPECIFIED.
F10:
NO EXTENSION (AUTOEXT) FOR THE 'AUTOMATIC LOGON' FEATURE
HAS YET BEEN ASSIGNED TO AGENT AGTID=@@@@@@
F11:
NO AGENT CONFIGURED WITH AGTID=@@@@@@.
F12:
THE NUMBER @@@@@@ ENTERED FOR 'NEWID'
(NEW AGENT IDENTIFICATION NUMBER) IS ALREADY IN USE.
F13:
THE STATION NUMBER @@@@@@ ENTERED FOR 'AUTOEXT'
IS ALREADY ASSIGNED TO AN OTHER AGENT.
F15:
SETTING AUTOWORK FOR PM AGENTS IS NOT POSSIBLE
F16:
ACD FEATURE IS BLOCKED.
ACTIVATE IT WITH THE FOLLOWING COMMAND:
CHANGE-
ZAND
:TYPE=ACD,ACDALLOW=YES;
F18:
AGENT AGENT=@@@@@@ IS STILL
REFERENCED BY ACD ROUTING TABLES.
ENTER COMMAND 'DISP-
ACDRT
;' AND SEARCH FOR ENTRIES
HAVING THE WORD 'AGTID' IN THE OUTPUT COLUMN
MARKED BY HEADER 'PARAMETER'. (ACTION=RTAGT)
F19:
MEMORY RESERVED FOR AGENTS IS INSUFFICIENT.
ALLOCATE ADDITIONAL MEMORY WITH THE FOLLOWING COMMAND:
ADD-
DIMSU
:ACDAGT=<?>;
F20:
THE NUMBER @@@@@@ ENTERED FOR 'AUTOEXT'
IS NOT YET CONFIGURED AS A STATION NUMBER.
(SEE AMO
SBCSU
,STNO)
F22:
STATION NUMBER AUTOEXT=@@@@@@ MUST FIRST BE
CLASSMARKED AS AN AGENT. SET REQUESTED
CLASSMARK WITH THE FOLLOWING COMMAND:"
CHANGE-
SDAT
:STNO=@@@@@@,TYPE=ATTRIBUT,AATTR=AGENT;
F24:
AGENT AGTID=@@@@@@ HAS NOT BEEN DELETED BECAUSE
THE APPROPRIATE DEVICE COULD NOT BE DEACTIVATED.
(NEGATIVE ACKNOWLEDGEMENT FROM CALL PROCESSING)
F26:
AGENT AGTID=@@@@@@ HAS NOT BEEN CHANGED BECAUSE
THE APPROPRIATE DEVICE COULD NOT BE DEACTIVATED.
(NEGATIVE ACKNOWLEDGEMENT FROM CALL PROCESSING)
F28:
AGENT AGTID=@@@@@@ MAY NOT BE MOVED TO GROUP
ACDGRP=^acdgrp^ BECAUSE BOTH PARAMETERS ARE
REFERENCED IN THE SAME ACD ROUTING TABLE (ART).
(THIS RESTRICTION CAN BE RELIEVED A LITTLE,
SEE AMO
ACDRT
, TYPE=ARTSTEP, ACT=RTAGT/RTGRP/COND)
F29:
AN AGENT ENDOWED WITH THE 'AUTOMATIC LOGON'
FEATURE (WHOSE 'AUTOEXT' HAS BEEN CONFIGURED)
MAY NOT BE MOVED TO THE FLEXIBLE ACD GROUP.
F30:
MEMORY RESERVED FOR AUTOMATIC LOGON AGENTS IS INSUFFICIENT.
ALLOCATE ADDITIONAL MEMORY WITH THE FOLLOWING COMMAND:
ADD-
DIMSU
:ACDLOGON=<?>;
F31:
A PM AGENT MUST JOIN A PM GROUP
F32:
A NORMAL AGENT MUST NOT JOIN A PM GROUP
F33:
DEL AUTOEXT IS ONLY ALLOWED FOR A NORMAL AGENT
F34:
INSUFFICIENT MEMORY SPACE (SEE AMO
DIMSU
, ACDAGT AND ACDPRIM)
F35:
TRUNK GROUP OF ACDPMGRP DOES NOT EQUAL TO INPUT ACDGRP
F36:
INPUT B-CHANNEL NOT AVAILABLE
F37:
B-CHANNEL @@ IS NOT OUT-OF-SERVICE.
PLEASE USE LONG TERM DEACTIVATION WITH THE FOLLOWING COMMAND:
DEACTIVATE-
DSSU
:OFFTYPE=L,TYPE=BCHAN,PEN1=<pen>,BCHL=<number>;
F38:
AUDIBLE SOURCE ID PERSANN=@@@ HAS YET TO BE CREATED (ADD-
RCSU
:OPMODE=CONT,OPTYPE=RANDOM, RECAPL=ACDR,RECNUM=@@@;).
F39:
THE APPLICATION TYPE ASSIGNED FOR RECORDER 'AUDSRCID' BY AMO
RCSU
MUST BE RECAPL=ACDR.
F40:
RECORDER 'AUDSRCID' MUST BE CONFIGURED WITH CONTINUOUS OPERATIONS MODE AND RANDOM START (CHANGE-
RCSU
,OPMODE=CONT,OPTYPE=RANDOM,RECNUM=;).
F41:
RECORDER 'AUDSRCID' MUST BE CONFIGURED WITH CONTINUOUS OPERATIONS MODE AND RANDOM START (CHANGE-
RCSU
,OPMODE=CONT,OPTYPE=RANDOM,RECNUM=;).
F42:
PARAMETER PERSANN IS NOT VALID FOR PHONEMAIL AGENTS.
F43:
THE SPECIFIED PEN IS NOT MEMBER OF A PM TRUNK GROUP (AMO
BUEND
,TDCSU).